Cargando…
Oxygen absorption data of multilayer oxygen scavenger-polyester films with different layouts
Oxygen absorption measurements in continuous regard active multilayer films with different layouts, all incorporating a PET/Oxygen scavenger (OS) layer, operating as active O(2) barrier, inserted between two PET inert layers, acting as passive O(2) barrier. The data set is related to “Transport prop...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6141150/ https://www.ncbi.nlm.nih.gov/pubmed/30229025 http://dx.doi.org/10.1016/j.dib.2018.06.024 |
_version_ | 1783355661378125824 |
---|---|
author | Apicella, A. Scarfato, P. Di Maio, L. Incarnato, L. |
author_facet | Apicella, A. Scarfato, P. Di Maio, L. Incarnato, L. |
author_sort | Apicella, A. |
collection | PubMed |
description | Oxygen absorption measurements in continuous regard active multilayer films with different layouts, all incorporating a PET/Oxygen scavenger (OS) layer, operating as active O(2) barrier, inserted between two PET inert layers, acting as passive O(2) barrier. The data set is related to “Transport properties of multilayer active PET films with different layers configuration” by Apicella et al. (2018) [1]. A set of four multilayer films, with different relative thickness of the active and inert layers, was produced using a laboratory scale co-extrusion cast-film equipment and was analyzed in terms of oxygen scavenging performance. Single layer active and inert layers were also produced for comparison. The results have shown a longer exhaustion time for all the active multilayer films, respect to the active monolayer one. Moreover, at constant thickness of the active layer, the exhaustion time increases by increasing the thickness of the inert layers, whereas, at constant thickness of the inert layers, the residual oxygen concentration decreases by increasing the thickness of the active layer. |
format | Online Article Text |
id | pubmed-6141150 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-61411502018-09-18 Oxygen absorption data of multilayer oxygen scavenger-polyester films with different layouts Apicella, A. Scarfato, P. Di Maio, L. Incarnato, L. Data Brief Materials Science Oxygen absorption measurements in continuous regard active multilayer films with different layouts, all incorporating a PET/Oxygen scavenger (OS) layer, operating as active O(2) barrier, inserted between two PET inert layers, acting as passive O(2) barrier. The data set is related to “Transport properties of multilayer active PET films with different layers configuration” by Apicella et al. (2018) [1]. A set of four multilayer films, with different relative thickness of the active and inert layers, was produced using a laboratory scale co-extrusion cast-film equipment and was analyzed in terms of oxygen scavenging performance. Single layer active and inert layers were also produced for comparison. The results have shown a longer exhaustion time for all the active multilayer films, respect to the active monolayer one. Moreover, at constant thickness of the active layer, the exhaustion time increases by increasing the thickness of the inert layers, whereas, at constant thickness of the inert layers, the residual oxygen concentration decreases by increasing the thickness of the active layer. Elsevier 2018-06-18 /pmc/articles/PMC6141150/ /pubmed/30229025 http://dx.doi.org/10.1016/j.dib.2018.06.024 Text en © 2018 The Authors http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Materials Science Apicella, A. Scarfato, P. Di Maio, L. Incarnato, L. Oxygen absorption data of multilayer oxygen scavenger-polyester films with different layouts |
title | Oxygen absorption data of multilayer oxygen scavenger-polyester films with different layouts |
title_full | Oxygen absorption data of multilayer oxygen scavenger-polyester films with different layouts |
title_fullStr | Oxygen absorption data of multilayer oxygen scavenger-polyester films with different layouts |
title_full_unstemmed | Oxygen absorption data of multilayer oxygen scavenger-polyester films with different layouts |
title_short | Oxygen absorption data of multilayer oxygen scavenger-polyester films with different layouts |
title_sort | oxygen absorption data of multilayer oxygen scavenger-polyester films with different layouts |
topic | Materials Science |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6141150/ https://www.ncbi.nlm.nih.gov/pubmed/30229025 http://dx.doi.org/10.1016/j.dib.2018.06.024 |
work_keys_str_mv | AT apicellaa oxygenabsorptiondataofmultilayeroxygenscavengerpolyesterfilmswithdifferentlayouts AT scarfatop oxygenabsorptiondataofmultilayeroxygenscavengerpolyesterfilmswithdifferentlayouts AT dimaiol oxygenabsorptiondataofmultilayeroxygenscavengerpolyesterfilmswithdifferentlayouts AT incarnatol oxygenabsorptiondataofmultilayeroxygenscavengerpolyesterfilmswithdifferentlayouts |