Performance of closed-loop resuscitation of haemorrhagic shock with fluid alone or in combination with norepinephrine: an experimental study
BACKGROUND: Closed-loop resuscitation can improve personalization of care, decrease workload and bring expert knowledge in isolated areas. We have developed a new device to control the administration of fluid or simultaneous co-administration of fluid and norepinephrine using arterial pressure. METH...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6141407/ https://www.ncbi.nlm.nih.gov/pubmed/30225814 http://dx.doi.org/10.1186/s13613-018-0436-0 |
_version_ | 1783355691144052736 |
---|---|
author | Libert, Nicolas Chenegros, Guillaume Harrois, Anatole Baudry, Nathalie Cordurie, Gilles Benosman, Ryad Vicaut, Eric Duranteau, Jacques |
author_facet | Libert, Nicolas Chenegros, Guillaume Harrois, Anatole Baudry, Nathalie Cordurie, Gilles Benosman, Ryad Vicaut, Eric Duranteau, Jacques |
author_sort | Libert, Nicolas |
collection | PubMed |
description | BACKGROUND: Closed-loop resuscitation can improve personalization of care, decrease workload and bring expert knowledge in isolated areas. We have developed a new device to control the administration of fluid or simultaneous co-administration of fluid and norepinephrine using arterial pressure. METHOD: We evaluated the performance of our prototype in a rodent model of haemorrhagic shock. After haemorrhagic shock, rats were randomized to five experimental groups: three were resuscitated with fluid and two with co-administration of fluid and norepinephrine. Among groups resuscitated with fluid, one was resuscitated by a physician and two were resuscitated according to two different closed-loop algorithms. Among groups resuscitated with fluid and norepinephrine, one was resuscitated by a physician and the other one by the closed-loop device. The precision of arterial pressure during the resuscitation period was assessed using rising time, time passed in the target area and performance error calculations. RESULTS: Groups resuscitated with fluid had similar performances and passed as much time in the target area of 80–90 mmHg as the manual group [manual: 76.8% (67.9–78.2), closed-loop: 64.6% (45.7–72.9) and 80.9% (59.1–85.3)]. Rats resuscitated with fluid and norepinephrine using closed-loop passed similar time in target area than manual group [closed-loop: 74.4% (58.4–84.5) vs. manual: 60.1% (46.1–72.4)] but had shorter rising time to reach target area [160 s (106–187) vs. 434 s (254–1081)] than those resuscitated by a physician. Rats resuscitated with co-administration of fluid and norepinephrine required less fluid and had less hemodilution than rats resuscitated with fluid alone. Lactate decrease was similar between groups resuscitated with fluid alone and fluid with norepinephrine. CONCLUSIONS: This study assessed extensively the performances of several algorithms for closed-loop resuscitation of haemorrhagic shock with fluid alone and with co-administration of fluid and norepinephrine. The performance of the closed-loop algorithms tested was similar to physician-guided treatment with considerable saving of work for the caregiver. Arterial pressure closed-loop guided algorithms can be extended to combined administration of fluid and norepinephrine. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s13613-018-0436-0) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-6141407 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Springer International Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-61414072018-09-28 Performance of closed-loop resuscitation of haemorrhagic shock with fluid alone or in combination with norepinephrine: an experimental study Libert, Nicolas Chenegros, Guillaume Harrois, Anatole Baudry, Nathalie Cordurie, Gilles Benosman, Ryad Vicaut, Eric Duranteau, Jacques Ann Intensive Care Research BACKGROUND: Closed-loop resuscitation can improve personalization of care, decrease workload and bring expert knowledge in isolated areas. We have developed a new device to control the administration of fluid or simultaneous co-administration of fluid and norepinephrine using arterial pressure. METHOD: We evaluated the performance of our prototype in a rodent model of haemorrhagic shock. After haemorrhagic shock, rats were randomized to five experimental groups: three were resuscitated with fluid and two with co-administration of fluid and norepinephrine. Among groups resuscitated with fluid, one was resuscitated by a physician and two were resuscitated according to two different closed-loop algorithms. Among groups resuscitated with fluid and norepinephrine, one was resuscitated by a physician and the other one by the closed-loop device. The precision of arterial pressure during the resuscitation period was assessed using rising time, time passed in the target area and performance error calculations. RESULTS: Groups resuscitated with fluid had similar performances and passed as much time in the target area of 80–90 mmHg as the manual group [manual: 76.8% (67.9–78.2), closed-loop: 64.6% (45.7–72.9) and 80.9% (59.1–85.3)]. Rats resuscitated with fluid and norepinephrine using closed-loop passed similar time in target area than manual group [closed-loop: 74.4% (58.4–84.5) vs. manual: 60.1% (46.1–72.4)] but had shorter rising time to reach target area [160 s (106–187) vs. 434 s (254–1081)] than those resuscitated by a physician. Rats resuscitated with co-administration of fluid and norepinephrine required less fluid and had less hemodilution than rats resuscitated with fluid alone. Lactate decrease was similar between groups resuscitated with fluid alone and fluid with norepinephrine. CONCLUSIONS: This study assessed extensively the performances of several algorithms for closed-loop resuscitation of haemorrhagic shock with fluid alone and with co-administration of fluid and norepinephrine. The performance of the closed-loop algorithms tested was similar to physician-guided treatment with considerable saving of work for the caregiver. Arterial pressure closed-loop guided algorithms can be extended to combined administration of fluid and norepinephrine. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s13613-018-0436-0) contains supplementary material, which is available to authorized users. Springer International Publishing 2018-09-17 /pmc/articles/PMC6141407/ /pubmed/30225814 http://dx.doi.org/10.1186/s13613-018-0436-0 Text en © The Author(s) 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Research Libert, Nicolas Chenegros, Guillaume Harrois, Anatole Baudry, Nathalie Cordurie, Gilles Benosman, Ryad Vicaut, Eric Duranteau, Jacques Performance of closed-loop resuscitation of haemorrhagic shock with fluid alone or in combination with norepinephrine: an experimental study |
title | Performance of closed-loop resuscitation of haemorrhagic shock with fluid alone or in combination with norepinephrine: an experimental study |
title_full | Performance of closed-loop resuscitation of haemorrhagic shock with fluid alone or in combination with norepinephrine: an experimental study |
title_fullStr | Performance of closed-loop resuscitation of haemorrhagic shock with fluid alone or in combination with norepinephrine: an experimental study |
title_full_unstemmed | Performance of closed-loop resuscitation of haemorrhagic shock with fluid alone or in combination with norepinephrine: an experimental study |
title_short | Performance of closed-loop resuscitation of haemorrhagic shock with fluid alone or in combination with norepinephrine: an experimental study |
title_sort | performance of closed-loop resuscitation of haemorrhagic shock with fluid alone or in combination with norepinephrine: an experimental study |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6141407/ https://www.ncbi.nlm.nih.gov/pubmed/30225814 http://dx.doi.org/10.1186/s13613-018-0436-0 |
work_keys_str_mv | AT libertnicolas performanceofclosedloopresuscitationofhaemorrhagicshockwithfluidaloneorincombinationwithnorepinephrineanexperimentalstudy AT chenegrosguillaume performanceofclosedloopresuscitationofhaemorrhagicshockwithfluidaloneorincombinationwithnorepinephrineanexperimentalstudy AT harroisanatole performanceofclosedloopresuscitationofhaemorrhagicshockwithfluidaloneorincombinationwithnorepinephrineanexperimentalstudy AT baudrynathalie performanceofclosedloopresuscitationofhaemorrhagicshockwithfluidaloneorincombinationwithnorepinephrineanexperimentalstudy AT corduriegilles performanceofclosedloopresuscitationofhaemorrhagicshockwithfluidaloneorincombinationwithnorepinephrineanexperimentalstudy AT benosmanryad performanceofclosedloopresuscitationofhaemorrhagicshockwithfluidaloneorincombinationwithnorepinephrineanexperimentalstudy AT vicauteric performanceofclosedloopresuscitationofhaemorrhagicshockwithfluidaloneorincombinationwithnorepinephrineanexperimentalstudy AT duranteaujacques performanceofclosedloopresuscitationofhaemorrhagicshockwithfluidaloneorincombinationwithnorepinephrineanexperimentalstudy |