Cargando…

The Safety of a Far Medial Arthroscopic Portal for Anatomic Glenoid Reconstruction: A Cadaveric Study

BACKGROUND: An arthroscopic technique for anatomic glenoid reconstruction has been proposed for the treatment of glenohumeral bone loss in patients with recurrent shoulder instability. This technique is proposed as an alternative to open techniques as well as to the technically challenging arthrosco...

Descripción completa

Detalles Bibliográficos
Autores principales: Moga, Iustin, Konstantinidis, George, Wong, Ivan Ho-Bun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6141923/
https://www.ncbi.nlm.nih.gov/pubmed/30238013
http://dx.doi.org/10.1177/2325967118795404
_version_ 1783355787738873856
author Moga, Iustin
Konstantinidis, George
Wong, Ivan Ho-Bun
author_facet Moga, Iustin
Konstantinidis, George
Wong, Ivan Ho-Bun
author_sort Moga, Iustin
collection PubMed
description BACKGROUND: An arthroscopic technique for anatomic glenoid reconstruction has been proposed for the treatment of glenohumeral bone loss in patients with recurrent shoulder instability. This technique is proposed as an alternative to open techniques as well as to the technically challenging arthroscopic Latarjet procedure. In arthroscopic anatomic glenoid reconstruction, a distal tibial allograft is inserted through a novel far medial portal, superior to the subscapularis tendon and lateral to the conjoint tendon. PURPOSE: To evaluate the safety of the far medial arthroscopic portal for anatomic glenoid reconstruction in a cadaveric study. STUDY DESIGN: Descriptive laboratory study. METHODS: Ten cadaveric shoulder specimens were dissected after inside-out medial arthroscopic portal insertion in the lateral decubitus position for arthroscopic anatomic glenoid reconstruction. A single observer performed 3 measurements on each specimen with a digital caliper (to the nearest 0.1 mm) from the medial portal to neurovascular structures, and the mean (±SD) and the range were calculated. The anthropometric data of the cadaveric specimens were also collected. RESULTS: The mean distances between the far medial arthroscopic portal and sensitive anatomic structures were as follows: 50.79 ± 13.69 mm from the musculocutaneous nerve, 46.28 ± 9.64 mm from the axillary nerve, 6.71 ± 8.52 mm from the cephalic vein, and 48.52 ± 7.22 mm from the subclavian artery and vein. The mean size of the medial arthroscopic portal was 25.60 mm. In all cases, the subscapularis muscle was intact. CONCLUSION: The far medial arthroscopic portal for anatomic glenoid reconstruction without a subscapularis split presents a minimal risk to most neurovascular structures during bony reconstruction of the glenoid surface in patients with anterior shoulder instability. The only anatomic structure at risk is the cephalic vein, while the axillary and musculocutaneous nerves are at a safe distance away from the portal, based on previous shoulder arthroscopic portal safety studies in the literature. CLINICAL RELEVANCE: Arthroscopic anatomic glenoid reconstruction using a distal tibial allograft is increasing in popularity for the treatment of anterior shoulder instability with significant bone loss. Being a relatively new technique, the safety of it has yet to be established. This study aimed to demonstrate the safety of a new portal used for arthroscopic anatomic glenoid reconstruction.
format Online
Article
Text
id pubmed-6141923
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-61419232018-09-20 The Safety of a Far Medial Arthroscopic Portal for Anatomic Glenoid Reconstruction: A Cadaveric Study Moga, Iustin Konstantinidis, George Wong, Ivan Ho-Bun Orthop J Sports Med Article BACKGROUND: An arthroscopic technique for anatomic glenoid reconstruction has been proposed for the treatment of glenohumeral bone loss in patients with recurrent shoulder instability. This technique is proposed as an alternative to open techniques as well as to the technically challenging arthroscopic Latarjet procedure. In arthroscopic anatomic glenoid reconstruction, a distal tibial allograft is inserted through a novel far medial portal, superior to the subscapularis tendon and lateral to the conjoint tendon. PURPOSE: To evaluate the safety of the far medial arthroscopic portal for anatomic glenoid reconstruction in a cadaveric study. STUDY DESIGN: Descriptive laboratory study. METHODS: Ten cadaveric shoulder specimens were dissected after inside-out medial arthroscopic portal insertion in the lateral decubitus position for arthroscopic anatomic glenoid reconstruction. A single observer performed 3 measurements on each specimen with a digital caliper (to the nearest 0.1 mm) from the medial portal to neurovascular structures, and the mean (±SD) and the range were calculated. The anthropometric data of the cadaveric specimens were also collected. RESULTS: The mean distances between the far medial arthroscopic portal and sensitive anatomic structures were as follows: 50.79 ± 13.69 mm from the musculocutaneous nerve, 46.28 ± 9.64 mm from the axillary nerve, 6.71 ± 8.52 mm from the cephalic vein, and 48.52 ± 7.22 mm from the subclavian artery and vein. The mean size of the medial arthroscopic portal was 25.60 mm. In all cases, the subscapularis muscle was intact. CONCLUSION: The far medial arthroscopic portal for anatomic glenoid reconstruction without a subscapularis split presents a minimal risk to most neurovascular structures during bony reconstruction of the glenoid surface in patients with anterior shoulder instability. The only anatomic structure at risk is the cephalic vein, while the axillary and musculocutaneous nerves are at a safe distance away from the portal, based on previous shoulder arthroscopic portal safety studies in the literature. CLINICAL RELEVANCE: Arthroscopic anatomic glenoid reconstruction using a distal tibial allograft is increasing in popularity for the treatment of anterior shoulder instability with significant bone loss. Being a relatively new technique, the safety of it has yet to be established. This study aimed to demonstrate the safety of a new portal used for arthroscopic anatomic glenoid reconstruction. SAGE Publications 2018-09-17 /pmc/articles/PMC6141923/ /pubmed/30238013 http://dx.doi.org/10.1177/2325967118795404 Text en © The Author(s) 2018 http://creativecommons.org/licenses/by-nc-nd/4.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 License (http://www.creativecommons.org/licenses/by-nc-nd/4.0/) which permits non-commercial use, reproduction and distribution of the work as published without adaptation or alteration, without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Article
Moga, Iustin
Konstantinidis, George
Wong, Ivan Ho-Bun
The Safety of a Far Medial Arthroscopic Portal for Anatomic Glenoid Reconstruction: A Cadaveric Study
title The Safety of a Far Medial Arthroscopic Portal for Anatomic Glenoid Reconstruction: A Cadaveric Study
title_full The Safety of a Far Medial Arthroscopic Portal for Anatomic Glenoid Reconstruction: A Cadaveric Study
title_fullStr The Safety of a Far Medial Arthroscopic Portal for Anatomic Glenoid Reconstruction: A Cadaveric Study
title_full_unstemmed The Safety of a Far Medial Arthroscopic Portal for Anatomic Glenoid Reconstruction: A Cadaveric Study
title_short The Safety of a Far Medial Arthroscopic Portal for Anatomic Glenoid Reconstruction: A Cadaveric Study
title_sort safety of a far medial arthroscopic portal for anatomic glenoid reconstruction: a cadaveric study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6141923/
https://www.ncbi.nlm.nih.gov/pubmed/30238013
http://dx.doi.org/10.1177/2325967118795404
work_keys_str_mv AT mogaiustin thesafetyofafarmedialarthroscopicportalforanatomicglenoidreconstructionacadavericstudy
AT konstantinidisgeorge thesafetyofafarmedialarthroscopicportalforanatomicglenoidreconstructionacadavericstudy
AT wongivanhobun thesafetyofafarmedialarthroscopicportalforanatomicglenoidreconstructionacadavericstudy
AT mogaiustin safetyofafarmedialarthroscopicportalforanatomicglenoidreconstructionacadavericstudy
AT konstantinidisgeorge safetyofafarmedialarthroscopicportalforanatomicglenoidreconstructionacadavericstudy
AT wongivanhobun safetyofafarmedialarthroscopicportalforanatomicglenoidreconstructionacadavericstudy