Cargando…
Effectiveness and safety of a robot-assisted 3D personalized template in (125)I seed brachytherapy of thoracoabdominal tumors
PURPOSE: This research aims to evaluate the effectiveness and safety of a robot-assisted 3D personalized template in (125)I seed brachytherapy of thoracoabdominal tumors. MATERIAL AND METHODS: Forty-three patients with different tumors were involved in this research between 2013 and 2015. They were...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Termedia Publishing House
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6142644/ https://www.ncbi.nlm.nih.gov/pubmed/30237820 http://dx.doi.org/10.5114/jcb.2018.77957 |
_version_ | 1783355864418091008 |
---|---|
author | Ma, Xiaodong Yang, Prof. Zhiyong Jiang, Prof. Shan Huo, Prof. Bin Cao, Qiang Chai, Prof. Shude Wang, Prof. Haitao |
author_facet | Ma, Xiaodong Yang, Prof. Zhiyong Jiang, Prof. Shan Huo, Prof. Bin Cao, Qiang Chai, Prof. Shude Wang, Prof. Haitao |
author_sort | Ma, Xiaodong |
collection | PubMed |
description | PURPOSE: This research aims to evaluate the effectiveness and safety of a robot-assisted 3D personalized template in (125)I seed brachytherapy of thoracoabdominal tumors. MATERIAL AND METHODS: Forty-three patients with different tumors were involved in this research between 2013 and 2015. They were all eligible to (125)I seed implantation based on robot-assisted 3D personalized template. Meanwhile, 51 patients with similar tumors, which were treated with a conventional coplanar template, were involved for comparison. Follow-up was carried out after the surgery to evaluate the therapeutic efficacy, including overall survival (OS) of the patient and local control (LC) of the tumor. Complications were also summarized to evaluate the safety. Besides, statistical analysis was achieved to investigate possible factors associated with the result. RESULTS: In the robot-assisted 3D personalized template-guided brachytherapy, the median target volume treated by the prescription dose (V(100)) was 95.3% (range, 92.4-109.8), and the median dose administered to 90% of the target volume (D(90)) was 126.1 Gy (range, 114.2-132.0), improved 5% and 8% compared with the conventional template-guided brachytherapy, respectively. The median OS was 30 months (95% CI: 19.4-40.6) and the rates of 2-year OS and LC were 58.1% and 86.0%, respectively. The median OS was prolonged 10 months and the 2-year OS and LC were improved 18.9% and 23.3% compared with the conventional template-guided brachytherapy, respectively. CONCLUSIONS: Through analysis of the selected patients with thoracoabdominal tumors, the robot-assisted 3D personalized template in (125)I seed brachytherapy was a more effective and safer method. It can achieve a more favorable OS and LC. |
format | Online Article Text |
id | pubmed-6142644 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Termedia Publishing House |
record_format | MEDLINE/PubMed |
spelling | pubmed-61426442018-09-20 Effectiveness and safety of a robot-assisted 3D personalized template in (125)I seed brachytherapy of thoracoabdominal tumors Ma, Xiaodong Yang, Prof. Zhiyong Jiang, Prof. Shan Huo, Prof. Bin Cao, Qiang Chai, Prof. Shude Wang, Prof. Haitao J Contemp Brachytherapy Original Paper PURPOSE: This research aims to evaluate the effectiveness and safety of a robot-assisted 3D personalized template in (125)I seed brachytherapy of thoracoabdominal tumors. MATERIAL AND METHODS: Forty-three patients with different tumors were involved in this research between 2013 and 2015. They were all eligible to (125)I seed implantation based on robot-assisted 3D personalized template. Meanwhile, 51 patients with similar tumors, which were treated with a conventional coplanar template, were involved for comparison. Follow-up was carried out after the surgery to evaluate the therapeutic efficacy, including overall survival (OS) of the patient and local control (LC) of the tumor. Complications were also summarized to evaluate the safety. Besides, statistical analysis was achieved to investigate possible factors associated with the result. RESULTS: In the robot-assisted 3D personalized template-guided brachytherapy, the median target volume treated by the prescription dose (V(100)) was 95.3% (range, 92.4-109.8), and the median dose administered to 90% of the target volume (D(90)) was 126.1 Gy (range, 114.2-132.0), improved 5% and 8% compared with the conventional template-guided brachytherapy, respectively. The median OS was 30 months (95% CI: 19.4-40.6) and the rates of 2-year OS and LC were 58.1% and 86.0%, respectively. The median OS was prolonged 10 months and the 2-year OS and LC were improved 18.9% and 23.3% compared with the conventional template-guided brachytherapy, respectively. CONCLUSIONS: Through analysis of the selected patients with thoracoabdominal tumors, the robot-assisted 3D personalized template in (125)I seed brachytherapy was a more effective and safer method. It can achieve a more favorable OS and LC. Termedia Publishing House 2018-08-31 2018-08 /pmc/articles/PMC6142644/ /pubmed/30237820 http://dx.doi.org/10.5114/jcb.2018.77957 Text en Copyright: © 2018 Termedia Sp. z o. o. http://creativecommons.org/licenses/by-nc-sa/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) License, allowing third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material, provided the original work is properly cited and states its license. |
spellingShingle | Original Paper Ma, Xiaodong Yang, Prof. Zhiyong Jiang, Prof. Shan Huo, Prof. Bin Cao, Qiang Chai, Prof. Shude Wang, Prof. Haitao Effectiveness and safety of a robot-assisted 3D personalized template in (125)I seed brachytherapy of thoracoabdominal tumors |
title | Effectiveness and safety of a robot-assisted 3D personalized template in (125)I seed brachytherapy of thoracoabdominal tumors |
title_full | Effectiveness and safety of a robot-assisted 3D personalized template in (125)I seed brachytherapy of thoracoabdominal tumors |
title_fullStr | Effectiveness and safety of a robot-assisted 3D personalized template in (125)I seed brachytherapy of thoracoabdominal tumors |
title_full_unstemmed | Effectiveness and safety of a robot-assisted 3D personalized template in (125)I seed brachytherapy of thoracoabdominal tumors |
title_short | Effectiveness and safety of a robot-assisted 3D personalized template in (125)I seed brachytherapy of thoracoabdominal tumors |
title_sort | effectiveness and safety of a robot-assisted 3d personalized template in (125)i seed brachytherapy of thoracoabdominal tumors |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6142644/ https://www.ncbi.nlm.nih.gov/pubmed/30237820 http://dx.doi.org/10.5114/jcb.2018.77957 |
work_keys_str_mv | AT maxiaodong effectivenessandsafetyofarobotassisted3dpersonalizedtemplatein125iseedbrachytherapyofthoracoabdominaltumors AT yangprofzhiyong effectivenessandsafetyofarobotassisted3dpersonalizedtemplatein125iseedbrachytherapyofthoracoabdominaltumors AT jiangprofshan effectivenessandsafetyofarobotassisted3dpersonalizedtemplatein125iseedbrachytherapyofthoracoabdominaltumors AT huoprofbin effectivenessandsafetyofarobotassisted3dpersonalizedtemplatein125iseedbrachytherapyofthoracoabdominaltumors AT caoqiang effectivenessandsafetyofarobotassisted3dpersonalizedtemplatein125iseedbrachytherapyofthoracoabdominaltumors AT chaiprofshude effectivenessandsafetyofarobotassisted3dpersonalizedtemplatein125iseedbrachytherapyofthoracoabdominaltumors AT wangprofhaitao effectivenessandsafetyofarobotassisted3dpersonalizedtemplatein125iseedbrachytherapyofthoracoabdominaltumors |