Cargando…

Development and preclinical testing of a novel biodegradable hydrogel vaginal packing technology for gynecologic high-dose-rate brachytherapy

PURPOSE: We evaluated the performance of a novel hydrogel-based strategy developed for clinical use as vaginal packing using phantoms and cadavers, and to compare the hydrogel to gauze and balloon packing. MATERIAL AND METHODS: The biocompatible hydrogel is based on a thiol-Michael addition reaction...

Descripción completa

Detalles Bibliográficos
Autores principales: Peach, Matthew Sean, Moore, Joanna, Giles, Wallis, Trainor, Justin, Long, Tim, Moon, Nicholas, Hylton, Joseph E., Showalter, Timothy N., Libby, Bruce
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Termedia Publishing House 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6142653/
https://www.ncbi.nlm.nih.gov/pubmed/30237814
http://dx.doi.org/10.5114/jcb.2018.77952
_version_ 1783355866524680192
author Peach, Matthew Sean
Moore, Joanna
Giles, Wallis
Trainor, Justin
Long, Tim
Moon, Nicholas
Hylton, Joseph E.
Showalter, Timothy N.
Libby, Bruce
author_facet Peach, Matthew Sean
Moore, Joanna
Giles, Wallis
Trainor, Justin
Long, Tim
Moon, Nicholas
Hylton, Joseph E.
Showalter, Timothy N.
Libby, Bruce
author_sort Peach, Matthew Sean
collection PubMed
description PURPOSE: We evaluated the performance of a novel hydrogel-based strategy developed for clinical use as vaginal packing using phantoms and cadavers, and to compare the hydrogel to gauze and balloon packing. MATERIAL AND METHODS: The biocompatible hydrogel is based on a thiol-Michael addition reaction, with delivery of reagents into the vaginal cavity using a custom-made system. Soft-cured cadavers were used for soft tissue-like mechanical properties. Two cadavers with intact uteri had magnetic resonance imaging (MRI) compatible with tandem and ovoids. For one cadaver, the temperature of the vaginal canal was measured before hydrogel application, during polymerization, and after hydrogel removal. The hydrogel packing and applicator was kept in a second cadaver, which was imaged using computed tomography (CT) and MRI. The hydrogel packing and imaging was repeated for an open multichannel MRI compatible, titanium-based vaginal cylinder placed in a post-hysterectomy cadaver. RESULTS: The gel reaction occurred within 90 seconds, indicating polymerization at clinical quantities with a 5°C increase in vaginal temperature. CT and MRI imaging identified the hydrogel readily and showed a conformance to anatomy with few air pockets. The entire hydrogel packing was readily retrieved upon completion of imaging. CONCLUSIONS: The novel strategy for polyethylene glycol (PEG)-based hydrogel intra-vaginal packing was able to rapidly polymerize in human cadavers with minimal heat production. Delivery was efficient and able to fill the contours of the vaginal cavity and displace tissue away from the applicator axis. The hydrogel has favorable imaging characteristics on CT and MRI, and shows a potential for clinical use, warranting additional studies for the use in humans.
format Online
Article
Text
id pubmed-6142653
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Termedia Publishing House
record_format MEDLINE/PubMed
spelling pubmed-61426532018-09-20 Development and preclinical testing of a novel biodegradable hydrogel vaginal packing technology for gynecologic high-dose-rate brachytherapy Peach, Matthew Sean Moore, Joanna Giles, Wallis Trainor, Justin Long, Tim Moon, Nicholas Hylton, Joseph E. Showalter, Timothy N. Libby, Bruce J Contemp Brachytherapy Original Paper PURPOSE: We evaluated the performance of a novel hydrogel-based strategy developed for clinical use as vaginal packing using phantoms and cadavers, and to compare the hydrogel to gauze and balloon packing. MATERIAL AND METHODS: The biocompatible hydrogel is based on a thiol-Michael addition reaction, with delivery of reagents into the vaginal cavity using a custom-made system. Soft-cured cadavers were used for soft tissue-like mechanical properties. Two cadavers with intact uteri had magnetic resonance imaging (MRI) compatible with tandem and ovoids. For one cadaver, the temperature of the vaginal canal was measured before hydrogel application, during polymerization, and after hydrogel removal. The hydrogel packing and applicator was kept in a second cadaver, which was imaged using computed tomography (CT) and MRI. The hydrogel packing and imaging was repeated for an open multichannel MRI compatible, titanium-based vaginal cylinder placed in a post-hysterectomy cadaver. RESULTS: The gel reaction occurred within 90 seconds, indicating polymerization at clinical quantities with a 5°C increase in vaginal temperature. CT and MRI imaging identified the hydrogel readily and showed a conformance to anatomy with few air pockets. The entire hydrogel packing was readily retrieved upon completion of imaging. CONCLUSIONS: The novel strategy for polyethylene glycol (PEG)-based hydrogel intra-vaginal packing was able to rapidly polymerize in human cadavers with minimal heat production. Delivery was efficient and able to fill the contours of the vaginal cavity and displace tissue away from the applicator axis. The hydrogel has favorable imaging characteristics on CT and MRI, and shows a potential for clinical use, warranting additional studies for the use in humans. Termedia Publishing House 2018-08-31 2018-08 /pmc/articles/PMC6142653/ /pubmed/30237814 http://dx.doi.org/10.5114/jcb.2018.77952 Text en Copyright: © 2018 Termedia Sp. z o. o. http://creativecommons.org/licenses/by-nc-sa/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) License, allowing third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material, provided the original work is properly cited and states its license.
spellingShingle Original Paper
Peach, Matthew Sean
Moore, Joanna
Giles, Wallis
Trainor, Justin
Long, Tim
Moon, Nicholas
Hylton, Joseph E.
Showalter, Timothy N.
Libby, Bruce
Development and preclinical testing of a novel biodegradable hydrogel vaginal packing technology for gynecologic high-dose-rate brachytherapy
title Development and preclinical testing of a novel biodegradable hydrogel vaginal packing technology for gynecologic high-dose-rate brachytherapy
title_full Development and preclinical testing of a novel biodegradable hydrogel vaginal packing technology for gynecologic high-dose-rate brachytherapy
title_fullStr Development and preclinical testing of a novel biodegradable hydrogel vaginal packing technology for gynecologic high-dose-rate brachytherapy
title_full_unstemmed Development and preclinical testing of a novel biodegradable hydrogel vaginal packing technology for gynecologic high-dose-rate brachytherapy
title_short Development and preclinical testing of a novel biodegradable hydrogel vaginal packing technology for gynecologic high-dose-rate brachytherapy
title_sort development and preclinical testing of a novel biodegradable hydrogel vaginal packing technology for gynecologic high-dose-rate brachytherapy
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6142653/
https://www.ncbi.nlm.nih.gov/pubmed/30237814
http://dx.doi.org/10.5114/jcb.2018.77952
work_keys_str_mv AT peachmatthewsean developmentandpreclinicaltestingofanovelbiodegradablehydrogelvaginalpackingtechnologyforgynecologichighdoseratebrachytherapy
AT moorejoanna developmentandpreclinicaltestingofanovelbiodegradablehydrogelvaginalpackingtechnologyforgynecologichighdoseratebrachytherapy
AT gileswallis developmentandpreclinicaltestingofanovelbiodegradablehydrogelvaginalpackingtechnologyforgynecologichighdoseratebrachytherapy
AT trainorjustin developmentandpreclinicaltestingofanovelbiodegradablehydrogelvaginalpackingtechnologyforgynecologichighdoseratebrachytherapy
AT longtim developmentandpreclinicaltestingofanovelbiodegradablehydrogelvaginalpackingtechnologyforgynecologichighdoseratebrachytherapy
AT moonnicholas developmentandpreclinicaltestingofanovelbiodegradablehydrogelvaginalpackingtechnologyforgynecologichighdoseratebrachytherapy
AT hyltonjosephe developmentandpreclinicaltestingofanovelbiodegradablehydrogelvaginalpackingtechnologyforgynecologichighdoseratebrachytherapy
AT showaltertimothyn developmentandpreclinicaltestingofanovelbiodegradablehydrogelvaginalpackingtechnologyforgynecologichighdoseratebrachytherapy
AT libbybruce developmentandpreclinicaltestingofanovelbiodegradablehydrogelvaginalpackingtechnologyforgynecologichighdoseratebrachytherapy