Cargando…
Development and preclinical testing of a novel biodegradable hydrogel vaginal packing technology for gynecologic high-dose-rate brachytherapy
PURPOSE: We evaluated the performance of a novel hydrogel-based strategy developed for clinical use as vaginal packing using phantoms and cadavers, and to compare the hydrogel to gauze and balloon packing. MATERIAL AND METHODS: The biocompatible hydrogel is based on a thiol-Michael addition reaction...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Termedia Publishing House
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6142653/ https://www.ncbi.nlm.nih.gov/pubmed/30237814 http://dx.doi.org/10.5114/jcb.2018.77952 |
_version_ | 1783355866524680192 |
---|---|
author | Peach, Matthew Sean Moore, Joanna Giles, Wallis Trainor, Justin Long, Tim Moon, Nicholas Hylton, Joseph E. Showalter, Timothy N. Libby, Bruce |
author_facet | Peach, Matthew Sean Moore, Joanna Giles, Wallis Trainor, Justin Long, Tim Moon, Nicholas Hylton, Joseph E. Showalter, Timothy N. Libby, Bruce |
author_sort | Peach, Matthew Sean |
collection | PubMed |
description | PURPOSE: We evaluated the performance of a novel hydrogel-based strategy developed for clinical use as vaginal packing using phantoms and cadavers, and to compare the hydrogel to gauze and balloon packing. MATERIAL AND METHODS: The biocompatible hydrogel is based on a thiol-Michael addition reaction, with delivery of reagents into the vaginal cavity using a custom-made system. Soft-cured cadavers were used for soft tissue-like mechanical properties. Two cadavers with intact uteri had magnetic resonance imaging (MRI) compatible with tandem and ovoids. For one cadaver, the temperature of the vaginal canal was measured before hydrogel application, during polymerization, and after hydrogel removal. The hydrogel packing and applicator was kept in a second cadaver, which was imaged using computed tomography (CT) and MRI. The hydrogel packing and imaging was repeated for an open multichannel MRI compatible, titanium-based vaginal cylinder placed in a post-hysterectomy cadaver. RESULTS: The gel reaction occurred within 90 seconds, indicating polymerization at clinical quantities with a 5°C increase in vaginal temperature. CT and MRI imaging identified the hydrogel readily and showed a conformance to anatomy with few air pockets. The entire hydrogel packing was readily retrieved upon completion of imaging. CONCLUSIONS: The novel strategy for polyethylene glycol (PEG)-based hydrogel intra-vaginal packing was able to rapidly polymerize in human cadavers with minimal heat production. Delivery was efficient and able to fill the contours of the vaginal cavity and displace tissue away from the applicator axis. The hydrogel has favorable imaging characteristics on CT and MRI, and shows a potential for clinical use, warranting additional studies for the use in humans. |
format | Online Article Text |
id | pubmed-6142653 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Termedia Publishing House |
record_format | MEDLINE/PubMed |
spelling | pubmed-61426532018-09-20 Development and preclinical testing of a novel biodegradable hydrogel vaginal packing technology for gynecologic high-dose-rate brachytherapy Peach, Matthew Sean Moore, Joanna Giles, Wallis Trainor, Justin Long, Tim Moon, Nicholas Hylton, Joseph E. Showalter, Timothy N. Libby, Bruce J Contemp Brachytherapy Original Paper PURPOSE: We evaluated the performance of a novel hydrogel-based strategy developed for clinical use as vaginal packing using phantoms and cadavers, and to compare the hydrogel to gauze and balloon packing. MATERIAL AND METHODS: The biocompatible hydrogel is based on a thiol-Michael addition reaction, with delivery of reagents into the vaginal cavity using a custom-made system. Soft-cured cadavers were used for soft tissue-like mechanical properties. Two cadavers with intact uteri had magnetic resonance imaging (MRI) compatible with tandem and ovoids. For one cadaver, the temperature of the vaginal canal was measured before hydrogel application, during polymerization, and after hydrogel removal. The hydrogel packing and applicator was kept in a second cadaver, which was imaged using computed tomography (CT) and MRI. The hydrogel packing and imaging was repeated for an open multichannel MRI compatible, titanium-based vaginal cylinder placed in a post-hysterectomy cadaver. RESULTS: The gel reaction occurred within 90 seconds, indicating polymerization at clinical quantities with a 5°C increase in vaginal temperature. CT and MRI imaging identified the hydrogel readily and showed a conformance to anatomy with few air pockets. The entire hydrogel packing was readily retrieved upon completion of imaging. CONCLUSIONS: The novel strategy for polyethylene glycol (PEG)-based hydrogel intra-vaginal packing was able to rapidly polymerize in human cadavers with minimal heat production. Delivery was efficient and able to fill the contours of the vaginal cavity and displace tissue away from the applicator axis. The hydrogel has favorable imaging characteristics on CT and MRI, and shows a potential for clinical use, warranting additional studies for the use in humans. Termedia Publishing House 2018-08-31 2018-08 /pmc/articles/PMC6142653/ /pubmed/30237814 http://dx.doi.org/10.5114/jcb.2018.77952 Text en Copyright: © 2018 Termedia Sp. z o. o. http://creativecommons.org/licenses/by-nc-sa/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) License, allowing third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material, provided the original work is properly cited and states its license. |
spellingShingle | Original Paper Peach, Matthew Sean Moore, Joanna Giles, Wallis Trainor, Justin Long, Tim Moon, Nicholas Hylton, Joseph E. Showalter, Timothy N. Libby, Bruce Development and preclinical testing of a novel biodegradable hydrogel vaginal packing technology for gynecologic high-dose-rate brachytherapy |
title | Development and preclinical testing of a novel biodegradable hydrogel vaginal packing technology for gynecologic high-dose-rate brachytherapy |
title_full | Development and preclinical testing of a novel biodegradable hydrogel vaginal packing technology for gynecologic high-dose-rate brachytherapy |
title_fullStr | Development and preclinical testing of a novel biodegradable hydrogel vaginal packing technology for gynecologic high-dose-rate brachytherapy |
title_full_unstemmed | Development and preclinical testing of a novel biodegradable hydrogel vaginal packing technology for gynecologic high-dose-rate brachytherapy |
title_short | Development and preclinical testing of a novel biodegradable hydrogel vaginal packing technology for gynecologic high-dose-rate brachytherapy |
title_sort | development and preclinical testing of a novel biodegradable hydrogel vaginal packing technology for gynecologic high-dose-rate brachytherapy |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6142653/ https://www.ncbi.nlm.nih.gov/pubmed/30237814 http://dx.doi.org/10.5114/jcb.2018.77952 |
work_keys_str_mv | AT peachmatthewsean developmentandpreclinicaltestingofanovelbiodegradablehydrogelvaginalpackingtechnologyforgynecologichighdoseratebrachytherapy AT moorejoanna developmentandpreclinicaltestingofanovelbiodegradablehydrogelvaginalpackingtechnologyforgynecologichighdoseratebrachytherapy AT gileswallis developmentandpreclinicaltestingofanovelbiodegradablehydrogelvaginalpackingtechnologyforgynecologichighdoseratebrachytherapy AT trainorjustin developmentandpreclinicaltestingofanovelbiodegradablehydrogelvaginalpackingtechnologyforgynecologichighdoseratebrachytherapy AT longtim developmentandpreclinicaltestingofanovelbiodegradablehydrogelvaginalpackingtechnologyforgynecologichighdoseratebrachytherapy AT moonnicholas developmentandpreclinicaltestingofanovelbiodegradablehydrogelvaginalpackingtechnologyforgynecologichighdoseratebrachytherapy AT hyltonjosephe developmentandpreclinicaltestingofanovelbiodegradablehydrogelvaginalpackingtechnologyforgynecologichighdoseratebrachytherapy AT showaltertimothyn developmentandpreclinicaltestingofanovelbiodegradablehydrogelvaginalpackingtechnologyforgynecologichighdoseratebrachytherapy AT libbybruce developmentandpreclinicaltestingofanovelbiodegradablehydrogelvaginalpackingtechnologyforgynecologichighdoseratebrachytherapy |