Cargando…
A Multiphysics Biventricular Cardiac Model: Simulations With a Left-Ventricular Assist Device
Computational models have become essential in predicting medical device efficacy prior to clinical studies. To investigate the performance of a left-ventricular assist device (LVAD), a fully-coupled cardiac fluid-electromechanics finite element model was developed, incorporating electrical activatio...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6142745/ https://www.ncbi.nlm.nih.gov/pubmed/30271353 http://dx.doi.org/10.3389/fphys.2018.01259 |
_version_ | 1783355887646146560 |
---|---|
author | Ahmad Bakir, Azam Al Abed, Amr Stevens, Michael C. Lovell, Nigel H. Dokos, Socrates |
author_facet | Ahmad Bakir, Azam Al Abed, Amr Stevens, Michael C. Lovell, Nigel H. Dokos, Socrates |
author_sort | Ahmad Bakir, Azam |
collection | PubMed |
description | Computational models have become essential in predicting medical device efficacy prior to clinical studies. To investigate the performance of a left-ventricular assist device (LVAD), a fully-coupled cardiac fluid-electromechanics finite element model was developed, incorporating electrical activation, passive and active myocardial mechanics, as well as blood hemodynamics solved simultaneously in an idealized biventricular geometry. Electrical activation was initiated using a simplified Purkinje network with one-way coupling to the surrounding myocardium. Phenomenological action potential and excitation-contraction equations were adapted to trigger myocardial contraction. Action potential propagation was formulated within a material frame to emulate gap junction-controlled propagation, such that the activation sequence was independent of myocardial deformation. Passive cardiac mechanics were governed by a transverse isotropic hyperelastic constitutive formulation. Blood velocity and pressure were determined by the incompressible Navier-Stokes formulations with a closed-loop Windkessel circuit governing the circulatory load. To investigate heart-LVAD interaction, we reduced the left ventricular (LV) contraction stress to mimic a failing heart, and inserted a LVAD cannula at the LV apex with continuous flow governing the outflow rate. A proportional controller was implemented to determine the pump motor voltage whilst maintaining pump motor speed. Following LVAD insertion, the model revealed a change in the LV pressure-volume loop shape from rectangular to triangular. At higher pump speeds, aortic ejection ceased and the LV decompressed to smaller end diastolic volumes. After multiple cycles, the LV cavity gradually collapsed along with a drop in pump motor current. The model was therefore able to predict ventricular collapse, indicating its utility for future development of control algorithms and pre-clinical testing of LVADs to avoid LV collapse in recipients. |
format | Online Article Text |
id | pubmed-6142745 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-61427452018-09-28 A Multiphysics Biventricular Cardiac Model: Simulations With a Left-Ventricular Assist Device Ahmad Bakir, Azam Al Abed, Amr Stevens, Michael C. Lovell, Nigel H. Dokos, Socrates Front Physiol Physiology Computational models have become essential in predicting medical device efficacy prior to clinical studies. To investigate the performance of a left-ventricular assist device (LVAD), a fully-coupled cardiac fluid-electromechanics finite element model was developed, incorporating electrical activation, passive and active myocardial mechanics, as well as blood hemodynamics solved simultaneously in an idealized biventricular geometry. Electrical activation was initiated using a simplified Purkinje network with one-way coupling to the surrounding myocardium. Phenomenological action potential and excitation-contraction equations were adapted to trigger myocardial contraction. Action potential propagation was formulated within a material frame to emulate gap junction-controlled propagation, such that the activation sequence was independent of myocardial deformation. Passive cardiac mechanics were governed by a transverse isotropic hyperelastic constitutive formulation. Blood velocity and pressure were determined by the incompressible Navier-Stokes formulations with a closed-loop Windkessel circuit governing the circulatory load. To investigate heart-LVAD interaction, we reduced the left ventricular (LV) contraction stress to mimic a failing heart, and inserted a LVAD cannula at the LV apex with continuous flow governing the outflow rate. A proportional controller was implemented to determine the pump motor voltage whilst maintaining pump motor speed. Following LVAD insertion, the model revealed a change in the LV pressure-volume loop shape from rectangular to triangular. At higher pump speeds, aortic ejection ceased and the LV decompressed to smaller end diastolic volumes. After multiple cycles, the LV cavity gradually collapsed along with a drop in pump motor current. The model was therefore able to predict ventricular collapse, indicating its utility for future development of control algorithms and pre-clinical testing of LVADs to avoid LV collapse in recipients. Frontiers Media S.A. 2018-09-11 /pmc/articles/PMC6142745/ /pubmed/30271353 http://dx.doi.org/10.3389/fphys.2018.01259 Text en Copyright © 2018 Ahmad Bakir, Al Abed, Stevens, Lovell and Dokos. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Physiology Ahmad Bakir, Azam Al Abed, Amr Stevens, Michael C. Lovell, Nigel H. Dokos, Socrates A Multiphysics Biventricular Cardiac Model: Simulations With a Left-Ventricular Assist Device |
title | A Multiphysics Biventricular Cardiac Model: Simulations With a Left-Ventricular Assist Device |
title_full | A Multiphysics Biventricular Cardiac Model: Simulations With a Left-Ventricular Assist Device |
title_fullStr | A Multiphysics Biventricular Cardiac Model: Simulations With a Left-Ventricular Assist Device |
title_full_unstemmed | A Multiphysics Biventricular Cardiac Model: Simulations With a Left-Ventricular Assist Device |
title_short | A Multiphysics Biventricular Cardiac Model: Simulations With a Left-Ventricular Assist Device |
title_sort | multiphysics biventricular cardiac model: simulations with a left-ventricular assist device |
topic | Physiology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6142745/ https://www.ncbi.nlm.nih.gov/pubmed/30271353 http://dx.doi.org/10.3389/fphys.2018.01259 |
work_keys_str_mv | AT ahmadbakirazam amultiphysicsbiventricularcardiacmodelsimulationswithaleftventricularassistdevice AT alabedamr amultiphysicsbiventricularcardiacmodelsimulationswithaleftventricularassistdevice AT stevensmichaelc amultiphysicsbiventricularcardiacmodelsimulationswithaleftventricularassistdevice AT lovellnigelh amultiphysicsbiventricularcardiacmodelsimulationswithaleftventricularassistdevice AT dokossocrates amultiphysicsbiventricularcardiacmodelsimulationswithaleftventricularassistdevice AT ahmadbakirazam multiphysicsbiventricularcardiacmodelsimulationswithaleftventricularassistdevice AT alabedamr multiphysicsbiventricularcardiacmodelsimulationswithaleftventricularassistdevice AT stevensmichaelc multiphysicsbiventricularcardiacmodelsimulationswithaleftventricularassistdevice AT lovellnigelh multiphysicsbiventricularcardiacmodelsimulationswithaleftventricularassistdevice AT dokossocrates multiphysicsbiventricularcardiacmodelsimulationswithaleftventricularassistdevice |