Cargando…

Investigation of Confounding Factors in Measuring Tissue Saturation with NIRS Spatially Resolved Spectroscopy

Performing absolute measurements of tissue saturation of the brain with near-infrared spectroscopy (NIRS) is a clinically desirable brain monitoring tool. Tissue oxygenation index (TOI) is an indicator of absolute tissue mixed arterial and venous oxygen saturation, and can be calculated using a NIRS...

Descripción completa

Detalles Bibliográficos
Autores principales: Kovacsova, Z., Bale, G., Mitra, S., de Roever, I., Meek, J., Robertson, N., Tachtsidis, I.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6142855/
https://www.ncbi.nlm.nih.gov/pubmed/30178363
http://dx.doi.org/10.1007/978-3-319-91287-5_49
_version_ 1783355909718671360
author Kovacsova, Z.
Bale, G.
Mitra, S.
de Roever, I.
Meek, J.
Robertson, N.
Tachtsidis, I.
author_facet Kovacsova, Z.
Bale, G.
Mitra, S.
de Roever, I.
Meek, J.
Robertson, N.
Tachtsidis, I.
author_sort Kovacsova, Z.
collection PubMed
description Performing absolute measurements of tissue saturation of the brain with near-infrared spectroscopy (NIRS) is a clinically desirable brain monitoring tool. Tissue oxygenation index (TOI) is an indicator of absolute tissue mixed arterial and venous oxygen saturation, and can be calculated using a NIRS technique called spatially resolved spectroscopy (SRS). SRS instruments measure the change of light attenuation with distance by using multiple light source-detector distances at two or more wavelengths. The aim of the study is to use broadband NIRS SRS data to investigate the effects on the calculation of TOI of different parameters: wavelength selection, scattering dependence, source-detector distance, and resolving for water. In total, 55 neonates with hypoxic-ischemic encephalopathy were monitored using a broadband multi-distance continuous wave NIRS system; 172 datasets were recorded. Using a “Standard” approach, TOI values between 0 and 100% (“good”) were calculated in 157/172 datasets with a mean TOI of 50%. By changing the wavelength selection, the number of “good” data sets increases to 165/172 with a mean of 60%. Alteration of the dependence of scattering on wavelength acts as a constant which shifts the absolute value of TOI significantly (p < 0.05), demonstrating the importance of having a subject-appropriate estimation of scattering dependence. In general, changing the combination of source-detector distances does not significantly alter the TOI (the mean TOI ranges from 41% to 53%) which suggests that the algorithm is robust to different source-detector combinations. The study shows the broadband NIRS SRS algorithm gives the opportunity to explore the calculation of TOI and could further improve the measurement of tissue saturation in a clinical setting.
format Online
Article
Text
id pubmed-6142855
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-61428552018-09-18 Investigation of Confounding Factors in Measuring Tissue Saturation with NIRS Spatially Resolved Spectroscopy Kovacsova, Z. Bale, G. Mitra, S. de Roever, I. Meek, J. Robertson, N. Tachtsidis, I. Adv Exp Med Biol Article Performing absolute measurements of tissue saturation of the brain with near-infrared spectroscopy (NIRS) is a clinically desirable brain monitoring tool. Tissue oxygenation index (TOI) is an indicator of absolute tissue mixed arterial and venous oxygen saturation, and can be calculated using a NIRS technique called spatially resolved spectroscopy (SRS). SRS instruments measure the change of light attenuation with distance by using multiple light source-detector distances at two or more wavelengths. The aim of the study is to use broadband NIRS SRS data to investigate the effects on the calculation of TOI of different parameters: wavelength selection, scattering dependence, source-detector distance, and resolving for water. In total, 55 neonates with hypoxic-ischemic encephalopathy were monitored using a broadband multi-distance continuous wave NIRS system; 172 datasets were recorded. Using a “Standard” approach, TOI values between 0 and 100% (“good”) were calculated in 157/172 datasets with a mean TOI of 50%. By changing the wavelength selection, the number of “good” data sets increases to 165/172 with a mean of 60%. Alteration of the dependence of scattering on wavelength acts as a constant which shifts the absolute value of TOI significantly (p < 0.05), demonstrating the importance of having a subject-appropriate estimation of scattering dependence. In general, changing the combination of source-detector distances does not significantly alter the TOI (the mean TOI ranges from 41% to 53%) which suggests that the algorithm is robust to different source-detector combinations. The study shows the broadband NIRS SRS algorithm gives the opportunity to explore the calculation of TOI and could further improve the measurement of tissue saturation in a clinical setting. Springer International Publishing 2018-04-16 /pmc/articles/PMC6142855/ /pubmed/30178363 http://dx.doi.org/10.1007/978-3-319-91287-5_49 Text en © The Author(s) 2018 Open Access This chapter is licensed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license and indicate if changes were made. The images or other third party material in this chapter are included in the chapter's Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the chapter's Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder.
spellingShingle Article
Kovacsova, Z.
Bale, G.
Mitra, S.
de Roever, I.
Meek, J.
Robertson, N.
Tachtsidis, I.
Investigation of Confounding Factors in Measuring Tissue Saturation with NIRS Spatially Resolved Spectroscopy
title Investigation of Confounding Factors in Measuring Tissue Saturation with NIRS Spatially Resolved Spectroscopy
title_full Investigation of Confounding Factors in Measuring Tissue Saturation with NIRS Spatially Resolved Spectroscopy
title_fullStr Investigation of Confounding Factors in Measuring Tissue Saturation with NIRS Spatially Resolved Spectroscopy
title_full_unstemmed Investigation of Confounding Factors in Measuring Tissue Saturation with NIRS Spatially Resolved Spectroscopy
title_short Investigation of Confounding Factors in Measuring Tissue Saturation with NIRS Spatially Resolved Spectroscopy
title_sort investigation of confounding factors in measuring tissue saturation with nirs spatially resolved spectroscopy
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6142855/
https://www.ncbi.nlm.nih.gov/pubmed/30178363
http://dx.doi.org/10.1007/978-3-319-91287-5_49
work_keys_str_mv AT kovacsovaz investigationofconfoundingfactorsinmeasuringtissuesaturationwithnirsspatiallyresolvedspectroscopy
AT baleg investigationofconfoundingfactorsinmeasuringtissuesaturationwithnirsspatiallyresolvedspectroscopy
AT mitras investigationofconfoundingfactorsinmeasuringtissuesaturationwithnirsspatiallyresolvedspectroscopy
AT deroeveri investigationofconfoundingfactorsinmeasuringtissuesaturationwithnirsspatiallyresolvedspectroscopy
AT meekj investigationofconfoundingfactorsinmeasuringtissuesaturationwithnirsspatiallyresolvedspectroscopy
AT robertsonn investigationofconfoundingfactorsinmeasuringtissuesaturationwithnirsspatiallyresolvedspectroscopy
AT tachtsidisi investigationofconfoundingfactorsinmeasuringtissuesaturationwithnirsspatiallyresolvedspectroscopy