Cargando…
Effectiveness of Platelet Function Analyzer-100 for Laboratory Detection of Anti-Platelet Drug-Induced Platelet Dysfunction
BACKGROUND: High on-treatment platelet reactivity (HTPR) is the phenomenon wherein patients exhibit normal platelet activity in laboratory testing despite adequate adherence to anti-platelet treatment. We investigated the detection rates of Platelet Function Analyzer (PFA)-100 (Dade Behring AG, Düdi...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society for Laboratory Medicine
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6143472/ https://www.ncbi.nlm.nih.gov/pubmed/30215226 http://dx.doi.org/10.3343/alm.2019.39.1.23 |
_version_ | 1783355978033397760 |
---|---|
author | Kweon, Oh Joo Lim, Yong Kwan Kim, Bohyun Lee, Mi-Kyung Kim, Hye Ryoun |
author_facet | Kweon, Oh Joo Lim, Yong Kwan Kim, Bohyun Lee, Mi-Kyung Kim, Hye Ryoun |
author_sort | Kweon, Oh Joo |
collection | PubMed |
description | BACKGROUND: High on-treatment platelet reactivity (HTPR) is the phenomenon wherein patients exhibit normal platelet activity in laboratory testing despite adequate adherence to anti-platelet treatment. We investigated the detection rates of Platelet Function Analyzer (PFA)-100 (Dade Behring AG, Düdingen, Switzerland) for drug-induced platelet dysfunction and analyzed potential contributors to HTPR with practical PFA-100 data over six years. METHODS: We used data from 6,957 patients who underwent PFA-100 testing after receiving aspirin, clopidogrel, or non-steroidal anti-inflammatory drugs (NSAIDs). Of these, 6,163 patients were tested with only the collagen/epinephrine cartridge (Col/EPI) of PFA-100; 794 were tested with both Col/EPI and the collagen/ADP cartridge (Col/ADP). We calculated PFA-100 closure time (CT) for each drug and compared the clinical and laboratory characteristics of the patients with prolonged CTs and normal CTs (i.e., HTPR). RESULTS: In Col/EPI, 73.2% (365/499), 72.6% (390/537), and 55.3% (3,442/6,228) patients showed prolonged CTs for aspirin, clopidogrel, and NSAIDs, respectively. In Col/ADP, prolonged CTs were observed in 37.4% (34/91), 43.2% (35/81), and 29.6% (200/676) of patients receiving aspirin, clopidogrel, and NSAIDs, respectively. Of the patients tested with both cartridges, 88.9% (48/54), 95.3% (41/43), and 89.0% (577/648) of the patients receiving aspirin, clopidogrel, and NSAIDs had prolonged CTs, and 10.0% (79/794) showed normal CTs regardless of drugs. For clopidogrel users (both cartridges), there were more patients with malignancies in the normal CT than prolonged CT group. CONCLUSIONS: PFA-100 is not sufficiently effective for laboratory screening of drug-induced platelet dysfunction. Malignancy may contribute to clopidogrel-related HTPR in PFA-100. |
format | Online Article Text |
id | pubmed-6143472 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | The Korean Society for Laboratory Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-61434722019-01-01 Effectiveness of Platelet Function Analyzer-100 for Laboratory Detection of Anti-Platelet Drug-Induced Platelet Dysfunction Kweon, Oh Joo Lim, Yong Kwan Kim, Bohyun Lee, Mi-Kyung Kim, Hye Ryoun Ann Lab Med Original Article BACKGROUND: High on-treatment platelet reactivity (HTPR) is the phenomenon wherein patients exhibit normal platelet activity in laboratory testing despite adequate adherence to anti-platelet treatment. We investigated the detection rates of Platelet Function Analyzer (PFA)-100 (Dade Behring AG, Düdingen, Switzerland) for drug-induced platelet dysfunction and analyzed potential contributors to HTPR with practical PFA-100 data over six years. METHODS: We used data from 6,957 patients who underwent PFA-100 testing after receiving aspirin, clopidogrel, or non-steroidal anti-inflammatory drugs (NSAIDs). Of these, 6,163 patients were tested with only the collagen/epinephrine cartridge (Col/EPI) of PFA-100; 794 were tested with both Col/EPI and the collagen/ADP cartridge (Col/ADP). We calculated PFA-100 closure time (CT) for each drug and compared the clinical and laboratory characteristics of the patients with prolonged CTs and normal CTs (i.e., HTPR). RESULTS: In Col/EPI, 73.2% (365/499), 72.6% (390/537), and 55.3% (3,442/6,228) patients showed prolonged CTs for aspirin, clopidogrel, and NSAIDs, respectively. In Col/ADP, prolonged CTs were observed in 37.4% (34/91), 43.2% (35/81), and 29.6% (200/676) of patients receiving aspirin, clopidogrel, and NSAIDs, respectively. Of the patients tested with both cartridges, 88.9% (48/54), 95.3% (41/43), and 89.0% (577/648) of the patients receiving aspirin, clopidogrel, and NSAIDs had prolonged CTs, and 10.0% (79/794) showed normal CTs regardless of drugs. For clopidogrel users (both cartridges), there were more patients with malignancies in the normal CT than prolonged CT group. CONCLUSIONS: PFA-100 is not sufficiently effective for laboratory screening of drug-induced platelet dysfunction. Malignancy may contribute to clopidogrel-related HTPR in PFA-100. The Korean Society for Laboratory Medicine 2019-01 2018-09-13 /pmc/articles/PMC6143472/ /pubmed/30215226 http://dx.doi.org/10.3343/alm.2019.39.1.23 Text en © The Korean Society for Laboratory Medicine http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Kweon, Oh Joo Lim, Yong Kwan Kim, Bohyun Lee, Mi-Kyung Kim, Hye Ryoun Effectiveness of Platelet Function Analyzer-100 for Laboratory Detection of Anti-Platelet Drug-Induced Platelet Dysfunction |
title | Effectiveness of Platelet Function Analyzer-100 for Laboratory Detection of Anti-Platelet Drug-Induced Platelet Dysfunction |
title_full | Effectiveness of Platelet Function Analyzer-100 for Laboratory Detection of Anti-Platelet Drug-Induced Platelet Dysfunction |
title_fullStr | Effectiveness of Platelet Function Analyzer-100 for Laboratory Detection of Anti-Platelet Drug-Induced Platelet Dysfunction |
title_full_unstemmed | Effectiveness of Platelet Function Analyzer-100 for Laboratory Detection of Anti-Platelet Drug-Induced Platelet Dysfunction |
title_short | Effectiveness of Platelet Function Analyzer-100 for Laboratory Detection of Anti-Platelet Drug-Induced Platelet Dysfunction |
title_sort | effectiveness of platelet function analyzer-100 for laboratory detection of anti-platelet drug-induced platelet dysfunction |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6143472/ https://www.ncbi.nlm.nih.gov/pubmed/30215226 http://dx.doi.org/10.3343/alm.2019.39.1.23 |
work_keys_str_mv | AT kweonohjoo effectivenessofplateletfunctionanalyzer100forlaboratorydetectionofantiplateletdruginducedplateletdysfunction AT limyongkwan effectivenessofplateletfunctionanalyzer100forlaboratorydetectionofantiplateletdruginducedplateletdysfunction AT kimbohyun effectivenessofplateletfunctionanalyzer100forlaboratorydetectionofantiplateletdruginducedplateletdysfunction AT leemikyung effectivenessofplateletfunctionanalyzer100forlaboratorydetectionofantiplateletdruginducedplateletdysfunction AT kimhyeryoun effectivenessofplateletfunctionanalyzer100forlaboratorydetectionofantiplateletdruginducedplateletdysfunction |