Cargando…

Effectiveness of Platelet Function Analyzer-100 for Laboratory Detection of Anti-Platelet Drug-Induced Platelet Dysfunction

BACKGROUND: High on-treatment platelet reactivity (HTPR) is the phenomenon wherein patients exhibit normal platelet activity in laboratory testing despite adequate adherence to anti-platelet treatment. We investigated the detection rates of Platelet Function Analyzer (PFA)-100 (Dade Behring AG, Düdi...

Descripción completa

Detalles Bibliográficos
Autores principales: Kweon, Oh Joo, Lim, Yong Kwan, Kim, Bohyun, Lee, Mi-Kyung, Kim, Hye Ryoun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society for Laboratory Medicine 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6143472/
https://www.ncbi.nlm.nih.gov/pubmed/30215226
http://dx.doi.org/10.3343/alm.2019.39.1.23
_version_ 1783355978033397760
author Kweon, Oh Joo
Lim, Yong Kwan
Kim, Bohyun
Lee, Mi-Kyung
Kim, Hye Ryoun
author_facet Kweon, Oh Joo
Lim, Yong Kwan
Kim, Bohyun
Lee, Mi-Kyung
Kim, Hye Ryoun
author_sort Kweon, Oh Joo
collection PubMed
description BACKGROUND: High on-treatment platelet reactivity (HTPR) is the phenomenon wherein patients exhibit normal platelet activity in laboratory testing despite adequate adherence to anti-platelet treatment. We investigated the detection rates of Platelet Function Analyzer (PFA)-100 (Dade Behring AG, Düdingen, Switzerland) for drug-induced platelet dysfunction and analyzed potential contributors to HTPR with practical PFA-100 data over six years. METHODS: We used data from 6,957 patients who underwent PFA-100 testing after receiving aspirin, clopidogrel, or non-steroidal anti-inflammatory drugs (NSAIDs). Of these, 6,163 patients were tested with only the collagen/epinephrine cartridge (Col/EPI) of PFA-100; 794 were tested with both Col/EPI and the collagen/ADP cartridge (Col/ADP). We calculated PFA-100 closure time (CT) for each drug and compared the clinical and laboratory characteristics of the patients with prolonged CTs and normal CTs (i.e., HTPR). RESULTS: In Col/EPI, 73.2% (365/499), 72.6% (390/537), and 55.3% (3,442/6,228) patients showed prolonged CTs for aspirin, clopidogrel, and NSAIDs, respectively. In Col/ADP, prolonged CTs were observed in 37.4% (34/91), 43.2% (35/81), and 29.6% (200/676) of patients receiving aspirin, clopidogrel, and NSAIDs, respectively. Of the patients tested with both cartridges, 88.9% (48/54), 95.3% (41/43), and 89.0% (577/648) of the patients receiving aspirin, clopidogrel, and NSAIDs had prolonged CTs, and 10.0% (79/794) showed normal CTs regardless of drugs. For clopidogrel users (both cartridges), there were more patients with malignancies in the normal CT than prolonged CT group. CONCLUSIONS: PFA-100 is not sufficiently effective for laboratory screening of drug-induced platelet dysfunction. Malignancy may contribute to clopidogrel-related HTPR in PFA-100.
format Online
Article
Text
id pubmed-6143472
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher The Korean Society for Laboratory Medicine
record_format MEDLINE/PubMed
spelling pubmed-61434722019-01-01 Effectiveness of Platelet Function Analyzer-100 for Laboratory Detection of Anti-Platelet Drug-Induced Platelet Dysfunction Kweon, Oh Joo Lim, Yong Kwan Kim, Bohyun Lee, Mi-Kyung Kim, Hye Ryoun Ann Lab Med Original Article BACKGROUND: High on-treatment platelet reactivity (HTPR) is the phenomenon wherein patients exhibit normal platelet activity in laboratory testing despite adequate adherence to anti-platelet treatment. We investigated the detection rates of Platelet Function Analyzer (PFA)-100 (Dade Behring AG, Düdingen, Switzerland) for drug-induced platelet dysfunction and analyzed potential contributors to HTPR with practical PFA-100 data over six years. METHODS: We used data from 6,957 patients who underwent PFA-100 testing after receiving aspirin, clopidogrel, or non-steroidal anti-inflammatory drugs (NSAIDs). Of these, 6,163 patients were tested with only the collagen/epinephrine cartridge (Col/EPI) of PFA-100; 794 were tested with both Col/EPI and the collagen/ADP cartridge (Col/ADP). We calculated PFA-100 closure time (CT) for each drug and compared the clinical and laboratory characteristics of the patients with prolonged CTs and normal CTs (i.e., HTPR). RESULTS: In Col/EPI, 73.2% (365/499), 72.6% (390/537), and 55.3% (3,442/6,228) patients showed prolonged CTs for aspirin, clopidogrel, and NSAIDs, respectively. In Col/ADP, prolonged CTs were observed in 37.4% (34/91), 43.2% (35/81), and 29.6% (200/676) of patients receiving aspirin, clopidogrel, and NSAIDs, respectively. Of the patients tested with both cartridges, 88.9% (48/54), 95.3% (41/43), and 89.0% (577/648) of the patients receiving aspirin, clopidogrel, and NSAIDs had prolonged CTs, and 10.0% (79/794) showed normal CTs regardless of drugs. For clopidogrel users (both cartridges), there were more patients with malignancies in the normal CT than prolonged CT group. CONCLUSIONS: PFA-100 is not sufficiently effective for laboratory screening of drug-induced platelet dysfunction. Malignancy may contribute to clopidogrel-related HTPR in PFA-100. The Korean Society for Laboratory Medicine 2019-01 2018-09-13 /pmc/articles/PMC6143472/ /pubmed/30215226 http://dx.doi.org/10.3343/alm.2019.39.1.23 Text en © The Korean Society for Laboratory Medicine http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Kweon, Oh Joo
Lim, Yong Kwan
Kim, Bohyun
Lee, Mi-Kyung
Kim, Hye Ryoun
Effectiveness of Platelet Function Analyzer-100 for Laboratory Detection of Anti-Platelet Drug-Induced Platelet Dysfunction
title Effectiveness of Platelet Function Analyzer-100 for Laboratory Detection of Anti-Platelet Drug-Induced Platelet Dysfunction
title_full Effectiveness of Platelet Function Analyzer-100 for Laboratory Detection of Anti-Platelet Drug-Induced Platelet Dysfunction
title_fullStr Effectiveness of Platelet Function Analyzer-100 for Laboratory Detection of Anti-Platelet Drug-Induced Platelet Dysfunction
title_full_unstemmed Effectiveness of Platelet Function Analyzer-100 for Laboratory Detection of Anti-Platelet Drug-Induced Platelet Dysfunction
title_short Effectiveness of Platelet Function Analyzer-100 for Laboratory Detection of Anti-Platelet Drug-Induced Platelet Dysfunction
title_sort effectiveness of platelet function analyzer-100 for laboratory detection of anti-platelet drug-induced platelet dysfunction
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6143472/
https://www.ncbi.nlm.nih.gov/pubmed/30215226
http://dx.doi.org/10.3343/alm.2019.39.1.23
work_keys_str_mv AT kweonohjoo effectivenessofplateletfunctionanalyzer100forlaboratorydetectionofantiplateletdruginducedplateletdysfunction
AT limyongkwan effectivenessofplateletfunctionanalyzer100forlaboratorydetectionofantiplateletdruginducedplateletdysfunction
AT kimbohyun effectivenessofplateletfunctionanalyzer100forlaboratorydetectionofantiplateletdruginducedplateletdysfunction
AT leemikyung effectivenessofplateletfunctionanalyzer100forlaboratorydetectionofantiplateletdruginducedplateletdysfunction
AT kimhyeryoun effectivenessofplateletfunctionanalyzer100forlaboratorydetectionofantiplateletdruginducedplateletdysfunction