Cargando…

Establishment of a novel homogeneous nanoparticle-based assay for sensitive procalcitonin detection of ultra low-volume serum samples

PURPOSE: Sepsis is a potentially fatal systemic body infection with a significant mortality rate worldwide. Although C-reactive protein (CRP), interleukin-6 (IL-6), and procalcitonin (PCT) might be biomarkers for sepsis diagnosis, PCT is more sensitive and specific than CRP or IL-6. We aimed to esta...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Peng, Chen, Zhenhua, Liu, Bing, Li, Kun, Wang, Hao, Lin, Li, He, Ling, Wei, Jie, Liu, Tiancai
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6143642/
https://www.ncbi.nlm.nih.gov/pubmed/30254442
http://dx.doi.org/10.2147/IJN.S173776
_version_ 1783356007400865792
author Li, Peng
Chen, Zhenhua
Liu, Bing
Li, Kun
Wang, Hao
Lin, Li
He, Ling
Wei, Jie
Liu, Tiancai
author_facet Li, Peng
Chen, Zhenhua
Liu, Bing
Li, Kun
Wang, Hao
Lin, Li
He, Ling
Wei, Jie
Liu, Tiancai
author_sort Li, Peng
collection PubMed
description PURPOSE: Sepsis is a potentially fatal systemic body infection with a significant mortality rate worldwide. Although C-reactive protein (CRP), interleukin-6 (IL-6), and procalcitonin (PCT) might be biomarkers for sepsis diagnosis, PCT is more sensitive and specific than CRP or IL-6. We aimed to establish an efficient immunoassay that precisely detects PCT in human serum for the early diagnosis of sepsis. MATERIALS AND METHODS: We developed a novel amplified luminescent proximity homogeneous assay (AlphaLISA) for the quantitative detection of PCT in serum. In this assay, a pair of antibodies was used to capture PCT in serum and to form sandwich complexes after incubating for 15 minutes at 37°C. RESULTS: PCT concentrations were determined within a linear range of 0.016–100 ng/mL. The limit of detection was 18.6 pg/mL. The results demonstrate that the reproducibility, recovery, and specificity of this assay for PCT meet the requirements of clinical detection. The coefficient of determination (R(2)) between this method and commercially available enzyme-linked fluorescent assay (ELFA) kits was estimated to be 0.93045 in clinical serum testing. CONCLUSION: The novel assay for PCT detection was robust with high sensitivity and a broad dynamic range. Compared with conventional heterogeneous detection methods such as ELISA, this assay measured the concentration of the homogeneous form of PCT and provided results that are more accurate within a shorter detection time. We expect that this novel method will be useful for the early screening and prognosis evaluation of patients with sepsis.
format Online
Article
Text
id pubmed-6143642
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-61436422018-09-25 Establishment of a novel homogeneous nanoparticle-based assay for sensitive procalcitonin detection of ultra low-volume serum samples Li, Peng Chen, Zhenhua Liu, Bing Li, Kun Wang, Hao Lin, Li He, Ling Wei, Jie Liu, Tiancai Int J Nanomedicine Original Research PURPOSE: Sepsis is a potentially fatal systemic body infection with a significant mortality rate worldwide. Although C-reactive protein (CRP), interleukin-6 (IL-6), and procalcitonin (PCT) might be biomarkers for sepsis diagnosis, PCT is more sensitive and specific than CRP or IL-6. We aimed to establish an efficient immunoassay that precisely detects PCT in human serum for the early diagnosis of sepsis. MATERIALS AND METHODS: We developed a novel amplified luminescent proximity homogeneous assay (AlphaLISA) for the quantitative detection of PCT in serum. In this assay, a pair of antibodies was used to capture PCT in serum and to form sandwich complexes after incubating for 15 minutes at 37°C. RESULTS: PCT concentrations were determined within a linear range of 0.016–100 ng/mL. The limit of detection was 18.6 pg/mL. The results demonstrate that the reproducibility, recovery, and specificity of this assay for PCT meet the requirements of clinical detection. The coefficient of determination (R(2)) between this method and commercially available enzyme-linked fluorescent assay (ELFA) kits was estimated to be 0.93045 in clinical serum testing. CONCLUSION: The novel assay for PCT detection was robust with high sensitivity and a broad dynamic range. Compared with conventional heterogeneous detection methods such as ELISA, this assay measured the concentration of the homogeneous form of PCT and provided results that are more accurate within a shorter detection time. We expect that this novel method will be useful for the early screening and prognosis evaluation of patients with sepsis. Dove Medical Press 2018-09-13 /pmc/articles/PMC6143642/ /pubmed/30254442 http://dx.doi.org/10.2147/IJN.S173776 Text en © 2018 Li et al. This work is published and licensed by Dove Medical Press Limited The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed.
spellingShingle Original Research
Li, Peng
Chen, Zhenhua
Liu, Bing
Li, Kun
Wang, Hao
Lin, Li
He, Ling
Wei, Jie
Liu, Tiancai
Establishment of a novel homogeneous nanoparticle-based assay for sensitive procalcitonin detection of ultra low-volume serum samples
title Establishment of a novel homogeneous nanoparticle-based assay for sensitive procalcitonin detection of ultra low-volume serum samples
title_full Establishment of a novel homogeneous nanoparticle-based assay for sensitive procalcitonin detection of ultra low-volume serum samples
title_fullStr Establishment of a novel homogeneous nanoparticle-based assay for sensitive procalcitonin detection of ultra low-volume serum samples
title_full_unstemmed Establishment of a novel homogeneous nanoparticle-based assay for sensitive procalcitonin detection of ultra low-volume serum samples
title_short Establishment of a novel homogeneous nanoparticle-based assay for sensitive procalcitonin detection of ultra low-volume serum samples
title_sort establishment of a novel homogeneous nanoparticle-based assay for sensitive procalcitonin detection of ultra low-volume serum samples
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6143642/
https://www.ncbi.nlm.nih.gov/pubmed/30254442
http://dx.doi.org/10.2147/IJN.S173776
work_keys_str_mv AT lipeng establishmentofanovelhomogeneousnanoparticlebasedassayforsensitiveprocalcitonindetectionofultralowvolumeserumsamples
AT chenzhenhua establishmentofanovelhomogeneousnanoparticlebasedassayforsensitiveprocalcitonindetectionofultralowvolumeserumsamples
AT liubing establishmentofanovelhomogeneousnanoparticlebasedassayforsensitiveprocalcitonindetectionofultralowvolumeserumsamples
AT likun establishmentofanovelhomogeneousnanoparticlebasedassayforsensitiveprocalcitonindetectionofultralowvolumeserumsamples
AT wanghao establishmentofanovelhomogeneousnanoparticlebasedassayforsensitiveprocalcitonindetectionofultralowvolumeserumsamples
AT linli establishmentofanovelhomogeneousnanoparticlebasedassayforsensitiveprocalcitonindetectionofultralowvolumeserumsamples
AT heling establishmentofanovelhomogeneousnanoparticlebasedassayforsensitiveprocalcitonindetectionofultralowvolumeserumsamples
AT weijie establishmentofanovelhomogeneousnanoparticlebasedassayforsensitiveprocalcitonindetectionofultralowvolumeserumsamples
AT liutiancai establishmentofanovelhomogeneousnanoparticlebasedassayforsensitiveprocalcitonindetectionofultralowvolumeserumsamples