Effect of Proparacaine 0.375%-Sodium Fluorescein 0.25% Eye Drop Mixture and Fluorescein Strip on Anterior Segment Parameters

PURPOSE: To determine the effect of proparacaine 0.375%-sodium fluorescein 0.25% eye drop mixture and fluorescein strip on anterior segment parameters commonly used in routine ophthalmology practice. METHODS: 115 healthy volunteers without any systemic or ocular disease were divided into two groups....

Descripción completa

Detalles Bibliográficos
Autores principales: Doğan, Mustafa, Sabaner, Mehmet Cem, Erol, Mehmet Akif
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6145059/
https://www.ncbi.nlm.nih.gov/pubmed/30254756
http://dx.doi.org/10.1155/2018/5926508
_version_ 1783356198776471552
author Doğan, Mustafa
Sabaner, Mehmet Cem
Erol, Mehmet Akif
author_facet Doğan, Mustafa
Sabaner, Mehmet Cem
Erol, Mehmet Akif
author_sort Doğan, Mustafa
collection PubMed
description PURPOSE: To determine the effect of proparacaine 0.375%-sodium fluorescein 0.25% eye drop mixture and fluorescein strip on anterior segment parameters commonly used in routine ophthalmology practice. METHODS: 115 healthy volunteers without any systemic or ocular disease were divided into two groups. 57 volunteers were in the proparacaine 0.375%-sodium fluorescein 0.25% eye drop mixture group, and 58 volunteers were in the fluorescein strip group. Measurements (CCT (central corneal thickness), topographic pupil diameter, AD (aqueous depth), ACV (anterior chamber volume), ICA (iridocorneal angle), LLD (limbus-limbus distance), and CV (corneal volume)) were taken before and at 1, 5, 15, and 30 minutes after application. RESULTS: 59 (51.3%) participants were female, and 56 (48.7%) were male. The mean age of the drop application group was 26.88 ± 8.03, and the mean age of the strip application group was 26.33 ± 7.28. The mean CCT was 556 ± 32 μm before drop application and 569 ± 30 μm in the 1st minute, 560 ± 32 μm in the 5th minute, and 559 ± 31 μm in the 15th minute. The change was statistically significant (p < 0.001, p=0.005, and p=0.013, resp.). Before the strip application, mean CCT was 552 ± 36 μm, while it increased to 556 ± 36 μm at the 1st minute, and this change was statistically significant (p=0.002). The mean CV before dropping was 59.29 ± 3.53 mm(3) and 60.62 ± 3.53 mm(3) at the 1st minute and 59.66 ± 3.70 mm(3) at the 5th minute, which was statistically significant (p < 0.001 and p=0.034). Mean topographic pupil diameters at the 1st, 5th, 15th, and 30th minute after application of drops and strips were not significantly changed compared to the preapplication values in the AD, ACV, ICA, and LLD measurements. CONCLUSIONS: Proparacaine 0.375%-sodium fluorescein 0.25% eye drop mixture and fluorescein strip application lead to a temporary change in CCT and CV of the anterior segment parameters. Anterior segment measurements with the Scheimpflug camera have to be done before topical fluorescein application.
format Online
Article
Text
id pubmed-6145059
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-61450592018-09-25 Effect of Proparacaine 0.375%-Sodium Fluorescein 0.25% Eye Drop Mixture and Fluorescein Strip on Anterior Segment Parameters Doğan, Mustafa Sabaner, Mehmet Cem Erol, Mehmet Akif J Ophthalmol Research Article PURPOSE: To determine the effect of proparacaine 0.375%-sodium fluorescein 0.25% eye drop mixture and fluorescein strip on anterior segment parameters commonly used in routine ophthalmology practice. METHODS: 115 healthy volunteers without any systemic or ocular disease were divided into two groups. 57 volunteers were in the proparacaine 0.375%-sodium fluorescein 0.25% eye drop mixture group, and 58 volunteers were in the fluorescein strip group. Measurements (CCT (central corneal thickness), topographic pupil diameter, AD (aqueous depth), ACV (anterior chamber volume), ICA (iridocorneal angle), LLD (limbus-limbus distance), and CV (corneal volume)) were taken before and at 1, 5, 15, and 30 minutes after application. RESULTS: 59 (51.3%) participants were female, and 56 (48.7%) were male. The mean age of the drop application group was 26.88 ± 8.03, and the mean age of the strip application group was 26.33 ± 7.28. The mean CCT was 556 ± 32 μm before drop application and 569 ± 30 μm in the 1st minute, 560 ± 32 μm in the 5th minute, and 559 ± 31 μm in the 15th minute. The change was statistically significant (p < 0.001, p=0.005, and p=0.013, resp.). Before the strip application, mean CCT was 552 ± 36 μm, while it increased to 556 ± 36 μm at the 1st minute, and this change was statistically significant (p=0.002). The mean CV before dropping was 59.29 ± 3.53 mm(3) and 60.62 ± 3.53 mm(3) at the 1st minute and 59.66 ± 3.70 mm(3) at the 5th minute, which was statistically significant (p < 0.001 and p=0.034). Mean topographic pupil diameters at the 1st, 5th, 15th, and 30th minute after application of drops and strips were not significantly changed compared to the preapplication values in the AD, ACV, ICA, and LLD measurements. CONCLUSIONS: Proparacaine 0.375%-sodium fluorescein 0.25% eye drop mixture and fluorescein strip application lead to a temporary change in CCT and CV of the anterior segment parameters. Anterior segment measurements with the Scheimpflug camera have to be done before topical fluorescein application. Hindawi 2018-09-05 /pmc/articles/PMC6145059/ /pubmed/30254756 http://dx.doi.org/10.1155/2018/5926508 Text en Copyright © 2018 Mustafa Doğan et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Doğan, Mustafa
Sabaner, Mehmet Cem
Erol, Mehmet Akif
Effect of Proparacaine 0.375%-Sodium Fluorescein 0.25% Eye Drop Mixture and Fluorescein Strip on Anterior Segment Parameters
title Effect of Proparacaine 0.375%-Sodium Fluorescein 0.25% Eye Drop Mixture and Fluorescein Strip on Anterior Segment Parameters
title_full Effect of Proparacaine 0.375%-Sodium Fluorescein 0.25% Eye Drop Mixture and Fluorescein Strip on Anterior Segment Parameters
title_fullStr Effect of Proparacaine 0.375%-Sodium Fluorescein 0.25% Eye Drop Mixture and Fluorescein Strip on Anterior Segment Parameters
title_full_unstemmed Effect of Proparacaine 0.375%-Sodium Fluorescein 0.25% Eye Drop Mixture and Fluorescein Strip on Anterior Segment Parameters
title_short Effect of Proparacaine 0.375%-Sodium Fluorescein 0.25% Eye Drop Mixture and Fluorescein Strip on Anterior Segment Parameters
title_sort effect of proparacaine 0.375%-sodium fluorescein 0.25% eye drop mixture and fluorescein strip on anterior segment parameters
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6145059/
https://www.ncbi.nlm.nih.gov/pubmed/30254756
http://dx.doi.org/10.1155/2018/5926508
work_keys_str_mv AT doganmustafa effectofproparacaine0375sodiumfluorescein025eyedropmixtureandfluoresceinstriponanteriorsegmentparameters
AT sabanermehmetcem effectofproparacaine0375sodiumfluorescein025eyedropmixtureandfluoresceinstriponanteriorsegmentparameters
AT erolmehmetakif effectofproparacaine0375sodiumfluorescein025eyedropmixtureandfluoresceinstriponanteriorsegmentparameters