Cargando…
CT-Guided Percutaneous Transthoracic Needle Biopsy Using the Additional Laser Guidance System by a Pulmonologist with 2 Years of Experience in CT-Guided Percutaneous Transthoracic Needle Biopsy
BACKGROUND: We developed an additional laser guidance system to improve the efficacy and safety of conventional computed tomography (CT)–guided percutaneous transthoracic needle biopsy (PTNB), and we conducted this study to evaluate the efficacy and safety of our system. METHODS: We retrospectively...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Academy of Tuberculosis and Respiratory Diseases
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6148095/ https://www.ncbi.nlm.nih.gov/pubmed/29926547 http://dx.doi.org/10.4046/trd.2017.0123 |
_version_ | 1783356697057689600 |
---|---|
author | Jeon, Min-Cheol Kim, Ju Ock Jung, Sung Soo Park, Hee Sun Lee, Jeong Eun Moon, Jae Young Chung, Chae Uk Kang, Da Hyun Park, Dong Il |
author_facet | Jeon, Min-Cheol Kim, Ju Ock Jung, Sung Soo Park, Hee Sun Lee, Jeong Eun Moon, Jae Young Chung, Chae Uk Kang, Da Hyun Park, Dong Il |
author_sort | Jeon, Min-Cheol |
collection | PubMed |
description | BACKGROUND: We developed an additional laser guidance system to improve the efficacy and safety of conventional computed tomography (CT)–guided percutaneous transthoracic needle biopsy (PTNB), and we conducted this study to evaluate the efficacy and safety of our system. METHODS: We retrospectively analyzed the medical records of 244 patients who underwent CT-guided PTNB using our additional laser guidance system from July 1, 2015, to January 20, 2016. RESULTS: There were nine false-negative results among the 238 total cases. The sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy of our system for diagnosing malignancy were 94.4% (152/161), 100% (77/77), 100% (152/152), 89.5% (77/86), and 96.2% (229/238), respectively. The results of univariate analysis showed that the risk factors for a false-negative result were male sex (p=0.029), a final diagnosis of malignancy (p=0.033), a lesion in the lower lobe (p=0.035), shorter distance from the skin to the target lesion (p=0.003), and shorter distance from the pleura to the target lesion (p=0.006). The overall complication rate was 30.5% (74/243). Pneumothorax, hemoptysis, and hemothorax occurred in 21.8% (53/243), 9.1% (22/243), and 1.6% (4/243) of cases, respectively. CONCLUSION: The additional laser guidance system might be a highly economical and efficient method to improve the diagnostic efficacy and safety of conventional CT-guided PTNB even if performed by inexperienced pulmonologists. |
format | Online Article Text |
id | pubmed-6148095 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | The Korean Academy of Tuberculosis and Respiratory Diseases |
record_format | MEDLINE/PubMed |
spelling | pubmed-61480952018-10-01 CT-Guided Percutaneous Transthoracic Needle Biopsy Using the Additional Laser Guidance System by a Pulmonologist with 2 Years of Experience in CT-Guided Percutaneous Transthoracic Needle Biopsy Jeon, Min-Cheol Kim, Ju Ock Jung, Sung Soo Park, Hee Sun Lee, Jeong Eun Moon, Jae Young Chung, Chae Uk Kang, Da Hyun Park, Dong Il Tuberc Respir Dis (Seoul) Original Article BACKGROUND: We developed an additional laser guidance system to improve the efficacy and safety of conventional computed tomography (CT)–guided percutaneous transthoracic needle biopsy (PTNB), and we conducted this study to evaluate the efficacy and safety of our system. METHODS: We retrospectively analyzed the medical records of 244 patients who underwent CT-guided PTNB using our additional laser guidance system from July 1, 2015, to January 20, 2016. RESULTS: There were nine false-negative results among the 238 total cases. The sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy of our system for diagnosing malignancy were 94.4% (152/161), 100% (77/77), 100% (152/152), 89.5% (77/86), and 96.2% (229/238), respectively. The results of univariate analysis showed that the risk factors for a false-negative result were male sex (p=0.029), a final diagnosis of malignancy (p=0.033), a lesion in the lower lobe (p=0.035), shorter distance from the skin to the target lesion (p=0.003), and shorter distance from the pleura to the target lesion (p=0.006). The overall complication rate was 30.5% (74/243). Pneumothorax, hemoptysis, and hemothorax occurred in 21.8% (53/243), 9.1% (22/243), and 1.6% (4/243) of cases, respectively. CONCLUSION: The additional laser guidance system might be a highly economical and efficient method to improve the diagnostic efficacy and safety of conventional CT-guided PTNB even if performed by inexperienced pulmonologists. The Korean Academy of Tuberculosis and Respiratory Diseases 2018-10 2018-06-19 /pmc/articles/PMC6148095/ /pubmed/29926547 http://dx.doi.org/10.4046/trd.2017.0123 Text en Copyright©2018. The Korean Academy of Tuberculosis and Respiratory Diseases http://creativecommons.org/licenses/by-nc/4.0/ It is identical to the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) |
spellingShingle | Original Article Jeon, Min-Cheol Kim, Ju Ock Jung, Sung Soo Park, Hee Sun Lee, Jeong Eun Moon, Jae Young Chung, Chae Uk Kang, Da Hyun Park, Dong Il CT-Guided Percutaneous Transthoracic Needle Biopsy Using the Additional Laser Guidance System by a Pulmonologist with 2 Years of Experience in CT-Guided Percutaneous Transthoracic Needle Biopsy |
title | CT-Guided Percutaneous Transthoracic Needle Biopsy Using the Additional Laser Guidance System by a Pulmonologist with 2 Years of Experience in CT-Guided Percutaneous Transthoracic Needle Biopsy |
title_full | CT-Guided Percutaneous Transthoracic Needle Biopsy Using the Additional Laser Guidance System by a Pulmonologist with 2 Years of Experience in CT-Guided Percutaneous Transthoracic Needle Biopsy |
title_fullStr | CT-Guided Percutaneous Transthoracic Needle Biopsy Using the Additional Laser Guidance System by a Pulmonologist with 2 Years of Experience in CT-Guided Percutaneous Transthoracic Needle Biopsy |
title_full_unstemmed | CT-Guided Percutaneous Transthoracic Needle Biopsy Using the Additional Laser Guidance System by a Pulmonologist with 2 Years of Experience in CT-Guided Percutaneous Transthoracic Needle Biopsy |
title_short | CT-Guided Percutaneous Transthoracic Needle Biopsy Using the Additional Laser Guidance System by a Pulmonologist with 2 Years of Experience in CT-Guided Percutaneous Transthoracic Needle Biopsy |
title_sort | ct-guided percutaneous transthoracic needle biopsy using the additional laser guidance system by a pulmonologist with 2 years of experience in ct-guided percutaneous transthoracic needle biopsy |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6148095/ https://www.ncbi.nlm.nih.gov/pubmed/29926547 http://dx.doi.org/10.4046/trd.2017.0123 |
work_keys_str_mv | AT jeonmincheol ctguidedpercutaneoustransthoracicneedlebiopsyusingtheadditionallaserguidancesystembyapulmonologistwith2yearsofexperienceinctguidedpercutaneoustransthoracicneedlebiopsy AT kimjuock ctguidedpercutaneoustransthoracicneedlebiopsyusingtheadditionallaserguidancesystembyapulmonologistwith2yearsofexperienceinctguidedpercutaneoustransthoracicneedlebiopsy AT jungsungsoo ctguidedpercutaneoustransthoracicneedlebiopsyusingtheadditionallaserguidancesystembyapulmonologistwith2yearsofexperienceinctguidedpercutaneoustransthoracicneedlebiopsy AT parkheesun ctguidedpercutaneoustransthoracicneedlebiopsyusingtheadditionallaserguidancesystembyapulmonologistwith2yearsofexperienceinctguidedpercutaneoustransthoracicneedlebiopsy AT leejeongeun ctguidedpercutaneoustransthoracicneedlebiopsyusingtheadditionallaserguidancesystembyapulmonologistwith2yearsofexperienceinctguidedpercutaneoustransthoracicneedlebiopsy AT moonjaeyoung ctguidedpercutaneoustransthoracicneedlebiopsyusingtheadditionallaserguidancesystembyapulmonologistwith2yearsofexperienceinctguidedpercutaneoustransthoracicneedlebiopsy AT chungchaeuk ctguidedpercutaneoustransthoracicneedlebiopsyusingtheadditionallaserguidancesystembyapulmonologistwith2yearsofexperienceinctguidedpercutaneoustransthoracicneedlebiopsy AT kangdahyun ctguidedpercutaneoustransthoracicneedlebiopsyusingtheadditionallaserguidancesystembyapulmonologistwith2yearsofexperienceinctguidedpercutaneoustransthoracicneedlebiopsy AT parkdongil ctguidedpercutaneoustransthoracicneedlebiopsyusingtheadditionallaserguidancesystembyapulmonologistwith2yearsofexperienceinctguidedpercutaneoustransthoracicneedlebiopsy |