Cargando…

Role of anatomical sites and correlated risk factors on the survival of orthodontic miniscrew implants: a systematic review and meta-analysis

OBJECTIVES: The aim of this review was to systematically evaluate the failure rates of miniscrews related to their specific insertion site and explore the insertion site dependent risk factors contributing to their failure. SEARCH METHODS: An electronic search was conducted in the Cochrane Central R...

Descripción completa

Detalles Bibliográficos
Autores principales: Mohammed, Hisham, Wafaie, Khaled, Rizk, Mumen Z., Almuzian, Mohammed, Sosly, Rami, Bearn, David R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6151309/
https://www.ncbi.nlm.nih.gov/pubmed/30246217
http://dx.doi.org/10.1186/s40510-018-0225-1
_version_ 1783357129127624704
author Mohammed, Hisham
Wafaie, Khaled
Rizk, Mumen Z.
Almuzian, Mohammed
Sosly, Rami
Bearn, David R.
author_facet Mohammed, Hisham
Wafaie, Khaled
Rizk, Mumen Z.
Almuzian, Mohammed
Sosly, Rami
Bearn, David R.
author_sort Mohammed, Hisham
collection PubMed
description OBJECTIVES: The aim of this review was to systematically evaluate the failure rates of miniscrews related to their specific insertion site and explore the insertion site dependent risk factors contributing to their failure. SEARCH METHODS: An electronic search was conducted in the Cochrane Central Register of Controlled Trials (CENTRAL), Web of Knowledge, Scopus, MEDLINE and PubMed up to October 2017. A comprehensive manual search was also performed. ELIGIBILITY CRITERIA: Randomised clinical trials and prospective non-randomised studies, reporting a minimum of 20 inserted miniscrews in a specific insertion site and reporting the miniscrews’ failure rate in that insertion site, were included. DATA COLLECTION AND ANALYSIS: Study selection, data extraction and quality assessment were performed independently by two reviewers. Studies were sub-grouped according to the insertion site, and the failure rates for every individual insertion site were analysed using a random-effects model with corresponding 95% confidence interval. Sensitivity analyses were performed in order to test the robustness of the reported results. RESULTS: Overall, 61 studies were included in the quantitative synthesis. Palatal sites had failure rates of 1.3% (95% CI 0.3–6), 4.8% (95% CI 1.6–13.4) and 5.5% (95% CI 2.8–10.7) for the midpalatal, paramedian and parapalatal insertion sites, respectively. The failure rates for the maxillary buccal sites were 9.2% (95% CI 7.4–11.4), 9.7% (95% CI 5.1–17.6) and 16.4% (95% CI 4.9–42.5) for the interradicular miniscrews inserted between maxillary first molars and second premolars and between maxillary canines and lateral incisors, and those inserted in the zygomatic buttress respectively. The failure rates for the mandibular buccal insertion sites were 13.5% (95% CI 7.3–23.6) and 9.9% (95% CI 4.9–19.1) for the interradicular miniscrews inserted between mandibular first molars and second premolars and between mandibular canines and first premolars, respectively. The risk of failure increased when the miniscrews contacted the roots, with a risk ratio of 8.7 (95% CI 5.1–14.7). CONCLUSIONS: Orthodontic miniscrew implants provide acceptable success rates that vary among the explored insertion sites. Very low to low quality of evidence suggests that miniscrews inserted in midpalatal locations have a failure rate of 1.3% and those inserted in the zygomatic buttress have a failure rate of 16.4%. Moderate quality of evidence indicates that root contact significantly contributes to the failure of interradicular miniscrews placed between the first molars and second premolars. Results should be interpreted with caution due to methodological drawbacks in some of the included studies. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s40510-018-0225-1) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-6151309
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-61513092018-10-09 Role of anatomical sites and correlated risk factors on the survival of orthodontic miniscrew implants: a systematic review and meta-analysis Mohammed, Hisham Wafaie, Khaled Rizk, Mumen Z. Almuzian, Mohammed Sosly, Rami Bearn, David R. Prog Orthod Review OBJECTIVES: The aim of this review was to systematically evaluate the failure rates of miniscrews related to their specific insertion site and explore the insertion site dependent risk factors contributing to their failure. SEARCH METHODS: An electronic search was conducted in the Cochrane Central Register of Controlled Trials (CENTRAL), Web of Knowledge, Scopus, MEDLINE and PubMed up to October 2017. A comprehensive manual search was also performed. ELIGIBILITY CRITERIA: Randomised clinical trials and prospective non-randomised studies, reporting a minimum of 20 inserted miniscrews in a specific insertion site and reporting the miniscrews’ failure rate in that insertion site, were included. DATA COLLECTION AND ANALYSIS: Study selection, data extraction and quality assessment were performed independently by two reviewers. Studies were sub-grouped according to the insertion site, and the failure rates for every individual insertion site were analysed using a random-effects model with corresponding 95% confidence interval. Sensitivity analyses were performed in order to test the robustness of the reported results. RESULTS: Overall, 61 studies were included in the quantitative synthesis. Palatal sites had failure rates of 1.3% (95% CI 0.3–6), 4.8% (95% CI 1.6–13.4) and 5.5% (95% CI 2.8–10.7) for the midpalatal, paramedian and parapalatal insertion sites, respectively. The failure rates for the maxillary buccal sites were 9.2% (95% CI 7.4–11.4), 9.7% (95% CI 5.1–17.6) and 16.4% (95% CI 4.9–42.5) for the interradicular miniscrews inserted between maxillary first molars and second premolars and between maxillary canines and lateral incisors, and those inserted in the zygomatic buttress respectively. The failure rates for the mandibular buccal insertion sites were 13.5% (95% CI 7.3–23.6) and 9.9% (95% CI 4.9–19.1) for the interradicular miniscrews inserted between mandibular first molars and second premolars and between mandibular canines and first premolars, respectively. The risk of failure increased when the miniscrews contacted the roots, with a risk ratio of 8.7 (95% CI 5.1–14.7). CONCLUSIONS: Orthodontic miniscrew implants provide acceptable success rates that vary among the explored insertion sites. Very low to low quality of evidence suggests that miniscrews inserted in midpalatal locations have a failure rate of 1.3% and those inserted in the zygomatic buttress have a failure rate of 16.4%. Moderate quality of evidence indicates that root contact significantly contributes to the failure of interradicular miniscrews placed between the first molars and second premolars. Results should be interpreted with caution due to methodological drawbacks in some of the included studies. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s40510-018-0225-1) contains supplementary material, which is available to authorized users. Springer Berlin Heidelberg 2018-09-24 /pmc/articles/PMC6151309/ /pubmed/30246217 http://dx.doi.org/10.1186/s40510-018-0225-1 Text en © The Author(s). 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Review
Mohammed, Hisham
Wafaie, Khaled
Rizk, Mumen Z.
Almuzian, Mohammed
Sosly, Rami
Bearn, David R.
Role of anatomical sites and correlated risk factors on the survival of orthodontic miniscrew implants: a systematic review and meta-analysis
title Role of anatomical sites and correlated risk factors on the survival of orthodontic miniscrew implants: a systematic review and meta-analysis
title_full Role of anatomical sites and correlated risk factors on the survival of orthodontic miniscrew implants: a systematic review and meta-analysis
title_fullStr Role of anatomical sites and correlated risk factors on the survival of orthodontic miniscrew implants: a systematic review and meta-analysis
title_full_unstemmed Role of anatomical sites and correlated risk factors on the survival of orthodontic miniscrew implants: a systematic review and meta-analysis
title_short Role of anatomical sites and correlated risk factors on the survival of orthodontic miniscrew implants: a systematic review and meta-analysis
title_sort role of anatomical sites and correlated risk factors on the survival of orthodontic miniscrew implants: a systematic review and meta-analysis
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6151309/
https://www.ncbi.nlm.nih.gov/pubmed/30246217
http://dx.doi.org/10.1186/s40510-018-0225-1
work_keys_str_mv AT mohammedhisham roleofanatomicalsitesandcorrelatedriskfactorsonthesurvivaloforthodonticminiscrewimplantsasystematicreviewandmetaanalysis
AT wafaiekhaled roleofanatomicalsitesandcorrelatedriskfactorsonthesurvivaloforthodonticminiscrewimplantsasystematicreviewandmetaanalysis
AT rizkmumenz roleofanatomicalsitesandcorrelatedriskfactorsonthesurvivaloforthodonticminiscrewimplantsasystematicreviewandmetaanalysis
AT almuzianmohammed roleofanatomicalsitesandcorrelatedriskfactorsonthesurvivaloforthodonticminiscrewimplantsasystematicreviewandmetaanalysis
AT soslyrami roleofanatomicalsitesandcorrelatedriskfactorsonthesurvivaloforthodonticminiscrewimplantsasystematicreviewandmetaanalysis
AT bearndavidr roleofanatomicalsitesandcorrelatedriskfactorsonthesurvivaloforthodonticminiscrewimplantsasystematicreviewandmetaanalysis