Cargando…

Is water exchange superior to water immersion for colonoscopy? A systematic review and meta-analysis

BACKGROUND/AIMS: Recently, water exchange (WE) instead of water immersion (WI) for colonoscopy has been proposed to decrease pain and improve adenoma detection rate (ADR). This systematic review and meta-analysis is conducted to assess whether WE is superior to WI based on the published randomized c...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Zhihao, Li, Zhengqi, Yu, Xinying, Wang, Guiqi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6151995/
https://www.ncbi.nlm.nih.gov/pubmed/29873319
http://dx.doi.org/10.4103/sjg.SJG_52_18
_version_ 1783357271270490112
author Chen, Zhihao
Li, Zhengqi
Yu, Xinying
Wang, Guiqi
author_facet Chen, Zhihao
Li, Zhengqi
Yu, Xinying
Wang, Guiqi
author_sort Chen, Zhihao
collection PubMed
description BACKGROUND/AIMS: Recently, water exchange (WE) instead of water immersion (WI) for colonoscopy has been proposed to decrease pain and improve adenoma detection rate (ADR). This systematic review and meta-analysis is conducted to assess whether WE is superior to WI based on the published randomized controlled trials (RCTs). MATERIALS AND METHODS: We searched studies from PubMed, Cochrane Central Register of Controlled Trials, EMBASE, and MEDLINE. Only RCTs were eligible for our study. The pooled risk ratios (RRs), pooled mean difference (MD), and pooled 95% confidence intervals (CIs) were calculated by using the fixed-effects model or random-effects model based on heterogeneity. RESULTS: Five RCTs consisting of 2229 colonoscopies were included in this study. WE was associated with a significantly higher ADR than WI (RR = 1.18; CI = 1.05–1.32; P = 0.004), especially in right colon (RR = 1.31; CI = 1.07–1.61; P = 0.01). Compared with WI, WE was confirmed with lower pain score, higher Boston Bowel Preparation Scale score, but more infused water during insertion. There was no statistical difference between WE and WI in cecal intubation rate and the number of patients who had willingness to repeat the examination. Furthermore, both total procedure time and cecal intubation time in WE were significantly longer than that in WI (MD = 2.66; CI = 1.42–3.90; P < 0.0001; vs MD = 4.58; CI = 4.01–5.15; P < 0.0001). CONCLUSIONS: This meta-analysis supports the hypothesis that WE is superior to WI in improving ADR, attenuating insertion pain and providing better bowel cleansing, but inferior in time and consumption of infused water consumption during insertion.
format Online
Article
Text
id pubmed-6151995
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-61519952018-10-03 Is water exchange superior to water immersion for colonoscopy? A systematic review and meta-analysis Chen, Zhihao Li, Zhengqi Yu, Xinying Wang, Guiqi Saudi J Gastroenterol Systematic Review/Meta-analysis BACKGROUND/AIMS: Recently, water exchange (WE) instead of water immersion (WI) for colonoscopy has been proposed to decrease pain and improve adenoma detection rate (ADR). This systematic review and meta-analysis is conducted to assess whether WE is superior to WI based on the published randomized controlled trials (RCTs). MATERIALS AND METHODS: We searched studies from PubMed, Cochrane Central Register of Controlled Trials, EMBASE, and MEDLINE. Only RCTs were eligible for our study. The pooled risk ratios (RRs), pooled mean difference (MD), and pooled 95% confidence intervals (CIs) were calculated by using the fixed-effects model or random-effects model based on heterogeneity. RESULTS: Five RCTs consisting of 2229 colonoscopies were included in this study. WE was associated with a significantly higher ADR than WI (RR = 1.18; CI = 1.05–1.32; P = 0.004), especially in right colon (RR = 1.31; CI = 1.07–1.61; P = 0.01). Compared with WI, WE was confirmed with lower pain score, higher Boston Bowel Preparation Scale score, but more infused water during insertion. There was no statistical difference between WE and WI in cecal intubation rate and the number of patients who had willingness to repeat the examination. Furthermore, both total procedure time and cecal intubation time in WE were significantly longer than that in WI (MD = 2.66; CI = 1.42–3.90; P < 0.0001; vs MD = 4.58; CI = 4.01–5.15; P < 0.0001). CONCLUSIONS: This meta-analysis supports the hypothesis that WE is superior to WI in improving ADR, attenuating insertion pain and providing better bowel cleansing, but inferior in time and consumption of infused water consumption during insertion. Medknow Publications & Media Pvt Ltd 2018 /pmc/articles/PMC6151995/ /pubmed/29873319 http://dx.doi.org/10.4103/sjg.SJG_52_18 Text en Copyright: © 2018 Saudi Journal of Gastroenterology http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Systematic Review/Meta-analysis
Chen, Zhihao
Li, Zhengqi
Yu, Xinying
Wang, Guiqi
Is water exchange superior to water immersion for colonoscopy? A systematic review and meta-analysis
title Is water exchange superior to water immersion for colonoscopy? A systematic review and meta-analysis
title_full Is water exchange superior to water immersion for colonoscopy? A systematic review and meta-analysis
title_fullStr Is water exchange superior to water immersion for colonoscopy? A systematic review and meta-analysis
title_full_unstemmed Is water exchange superior to water immersion for colonoscopy? A systematic review and meta-analysis
title_short Is water exchange superior to water immersion for colonoscopy? A systematic review and meta-analysis
title_sort is water exchange superior to water immersion for colonoscopy? a systematic review and meta-analysis
topic Systematic Review/Meta-analysis
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6151995/
https://www.ncbi.nlm.nih.gov/pubmed/29873319
http://dx.doi.org/10.4103/sjg.SJG_52_18
work_keys_str_mv AT chenzhihao iswaterexchangesuperiortowaterimmersionforcolonoscopyasystematicreviewandmetaanalysis
AT lizhengqi iswaterexchangesuperiortowaterimmersionforcolonoscopyasystematicreviewandmetaanalysis
AT yuxinying iswaterexchangesuperiortowaterimmersionforcolonoscopyasystematicreviewandmetaanalysis
AT wangguiqi iswaterexchangesuperiortowaterimmersionforcolonoscopyasystematicreviewandmetaanalysis