Cargando…

Robotic Surgery Improves Technical Performance and Enhances Prefrontal Activation During High Temporal Demand

Robotic surgery may improve technical performance and reduce mental demands compared to laparoscopic surgery. However, no studies have directly compared the impact of robotic and laparoscopic techniques on surgeons’ brain function. This study aimed to assess the effect of the operative platform (rob...

Descripción completa

Detalles Bibliográficos
Autores principales: Singh, Harsimrat, Modi, Hemel N., Ranjan, Samriddha, Dilley, James W. R., Airantzis, Dimitrios, Yang, Guang-Zhong, Darzi, Ara, Leff, Daniel R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer US 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6153983/
https://www.ncbi.nlm.nih.gov/pubmed/29869104
http://dx.doi.org/10.1007/s10439-018-2049-z
_version_ 1783357607780548608
author Singh, Harsimrat
Modi, Hemel N.
Ranjan, Samriddha
Dilley, James W. R.
Airantzis, Dimitrios
Yang, Guang-Zhong
Darzi, Ara
Leff, Daniel R.
author_facet Singh, Harsimrat
Modi, Hemel N.
Ranjan, Samriddha
Dilley, James W. R.
Airantzis, Dimitrios
Yang, Guang-Zhong
Darzi, Ara
Leff, Daniel R.
author_sort Singh, Harsimrat
collection PubMed
description Robotic surgery may improve technical performance and reduce mental demands compared to laparoscopic surgery. However, no studies have directly compared the impact of robotic and laparoscopic techniques on surgeons’ brain function. This study aimed to assess the effect of the operative platform (robotic surgery or conventional laparoscopy) on prefrontal cortical activation during a suturing task performed under temporal demand. Eight surgeons (mean age ± SD = 34.5 ± 2.9 years, male:female ratio = 7:1) performed an intracorporeal suturing task in a self-paced manner and under a 2 min time restriction using conventional laparoscopic and robotic techniques. Prefrontal activation was assessed using near-infrared spectroscopy, subjective workload was captured using SURG-TLX questionnaires, and a continuous heart rate monitor measured systemic stress responses. Task progression scores (au), error scores (au), leak volumes (mL) and knot tensile strengths (N) provided objective assessment of technical performance. Under time pressure, robotic suturing led to improved technical performance (median task progression score: laparoscopic suturing = 4.5 vs. robotic suturing = 5.0; z = − 2.107, p = 0.035; median error score: laparoscopic suturing = 3.0 mm vs. robotic suturing = 2.1 mm; z = − 2.488, p = 0.013). Compared to laparoscopic suturing, greater prefrontal activation was identified in seven channels located primarily in lateral prefrontal regions. These results suggest that robotic surgery improves performance during high workload conditions and is associated with enhanced activation in regions of attention, concentration and task engagement. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s10439-018-2049-z) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-6153983
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Springer US
record_format MEDLINE/PubMed
spelling pubmed-61539832018-10-04 Robotic Surgery Improves Technical Performance and Enhances Prefrontal Activation During High Temporal Demand Singh, Harsimrat Modi, Hemel N. Ranjan, Samriddha Dilley, James W. R. Airantzis, Dimitrios Yang, Guang-Zhong Darzi, Ara Leff, Daniel R. Ann Biomed Eng Medical Robotics Robotic surgery may improve technical performance and reduce mental demands compared to laparoscopic surgery. However, no studies have directly compared the impact of robotic and laparoscopic techniques on surgeons’ brain function. This study aimed to assess the effect of the operative platform (robotic surgery or conventional laparoscopy) on prefrontal cortical activation during a suturing task performed under temporal demand. Eight surgeons (mean age ± SD = 34.5 ± 2.9 years, male:female ratio = 7:1) performed an intracorporeal suturing task in a self-paced manner and under a 2 min time restriction using conventional laparoscopic and robotic techniques. Prefrontal activation was assessed using near-infrared spectroscopy, subjective workload was captured using SURG-TLX questionnaires, and a continuous heart rate monitor measured systemic stress responses. Task progression scores (au), error scores (au), leak volumes (mL) and knot tensile strengths (N) provided objective assessment of technical performance. Under time pressure, robotic suturing led to improved technical performance (median task progression score: laparoscopic suturing = 4.5 vs. robotic suturing = 5.0; z = − 2.107, p = 0.035; median error score: laparoscopic suturing = 3.0 mm vs. robotic suturing = 2.1 mm; z = − 2.488, p = 0.013). Compared to laparoscopic suturing, greater prefrontal activation was identified in seven channels located primarily in lateral prefrontal regions. These results suggest that robotic surgery improves performance during high workload conditions and is associated with enhanced activation in regions of attention, concentration and task engagement. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s10439-018-2049-z) contains supplementary material, which is available to authorized users. Springer US 2018-06-04 2018 /pmc/articles/PMC6153983/ /pubmed/29869104 http://dx.doi.org/10.1007/s10439-018-2049-z Text en © Biomedical Engineering Society 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Medical Robotics
Singh, Harsimrat
Modi, Hemel N.
Ranjan, Samriddha
Dilley, James W. R.
Airantzis, Dimitrios
Yang, Guang-Zhong
Darzi, Ara
Leff, Daniel R.
Robotic Surgery Improves Technical Performance and Enhances Prefrontal Activation During High Temporal Demand
title Robotic Surgery Improves Technical Performance and Enhances Prefrontal Activation During High Temporal Demand
title_full Robotic Surgery Improves Technical Performance and Enhances Prefrontal Activation During High Temporal Demand
title_fullStr Robotic Surgery Improves Technical Performance and Enhances Prefrontal Activation During High Temporal Demand
title_full_unstemmed Robotic Surgery Improves Technical Performance and Enhances Prefrontal Activation During High Temporal Demand
title_short Robotic Surgery Improves Technical Performance and Enhances Prefrontal Activation During High Temporal Demand
title_sort robotic surgery improves technical performance and enhances prefrontal activation during high temporal demand
topic Medical Robotics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6153983/
https://www.ncbi.nlm.nih.gov/pubmed/29869104
http://dx.doi.org/10.1007/s10439-018-2049-z
work_keys_str_mv AT singhharsimrat roboticsurgeryimprovestechnicalperformanceandenhancesprefrontalactivationduringhightemporaldemand
AT modihemeln roboticsurgeryimprovestechnicalperformanceandenhancesprefrontalactivationduringhightemporaldemand
AT ranjansamriddha roboticsurgeryimprovestechnicalperformanceandenhancesprefrontalactivationduringhightemporaldemand
AT dilleyjameswr roboticsurgeryimprovestechnicalperformanceandenhancesprefrontalactivationduringhightemporaldemand
AT airantzisdimitrios roboticsurgeryimprovestechnicalperformanceandenhancesprefrontalactivationduringhightemporaldemand
AT yangguangzhong roboticsurgeryimprovestechnicalperformanceandenhancesprefrontalactivationduringhightemporaldemand
AT darziara roboticsurgeryimprovestechnicalperformanceandenhancesprefrontalactivationduringhightemporaldemand
AT leffdanielr roboticsurgeryimprovestechnicalperformanceandenhancesprefrontalactivationduringhightemporaldemand