Cargando…
Enabling second harmonic generation as a contrast mechanism for optical projection tomography (OPT) and scanning laser optical tomography (SLOT)
Volumetric imaging of connective tissue provides insights into the structure of biological tissue. Second harmonic generation (SHG) microscopy has become a standard method to image collagen rich tissue like skin or cornea. Due to the non-centrosymmetric architecture, no additional label is needed an...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Optical Society of America
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6154203/ https://www.ncbi.nlm.nih.gov/pubmed/30258678 http://dx.doi.org/10.1364/BOE.9.002627 |
_version_ | 1783357656580227072 |
---|---|
author | Nolte, Lena Antonopoulos, Georgios C. Rämisch, Lisa Heisterkamp, Alexander Ripken, Tammo Meyer, Heiko |
author_facet | Nolte, Lena Antonopoulos, Georgios C. Rämisch, Lisa Heisterkamp, Alexander Ripken, Tammo Meyer, Heiko |
author_sort | Nolte, Lena |
collection | PubMed |
description | Volumetric imaging of connective tissue provides insights into the structure of biological tissue. Second harmonic generation (SHG) microscopy has become a standard method to image collagen rich tissue like skin or cornea. Due to the non-centrosymmetric architecture, no additional label is needed and tissue can be visualized noninvasively. Thus, SHG microscopy enables the investigation of collagen associated diseases, providing high resolution images and a field of view of several hundreds of μm. However, the in toto visualization of larger samples is limited to the working distance of the objective and the integration time of the microscope setup, which can sum up to several hours and days. A faster imaging technique for samples in the mesoscopic range is scanning laser optical tomography (SLOT), which provides linear fluorescence, scattering and absorption as intrinsic contrast mechanisms. Due to the advantages of SHG and the reduced measurement time of SLOT, the integration of SHG in SLOT would be a great extension. This way SHG measurements could be performed faster on large samples, providing isotropic resolution and simultaneous acquisition of all other contrast mechanisms available, such as fluorescence and absorption. SLOT is based on the principle of computed tomography, which requires the rotation of the sample. The SHG signal, however, depends strongly on the sample orientation and the polarization of the laser, which results in SHG intensity fluctuation during sample rotation and prevents successful 3D reconstruction. In this paper we investigate the angular dependence of the SHG signal by simulation and experiment and found a way to eliminate reconstruction artifacts caused by this angular dependence in SHG-SLOT data. This way, it is now possible to visualize samples in the mesoscopic range using SHG-SLOT, with isotropic resolution and in correlation to other contrast mechanisms as absorption, fluorescence and scattering. |
format | Online Article Text |
id | pubmed-6154203 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Optical Society of America |
record_format | MEDLINE/PubMed |
spelling | pubmed-61542032018-09-26 Enabling second harmonic generation as a contrast mechanism for optical projection tomography (OPT) and scanning laser optical tomography (SLOT) Nolte, Lena Antonopoulos, Georgios C. Rämisch, Lisa Heisterkamp, Alexander Ripken, Tammo Meyer, Heiko Biomed Opt Express Article Volumetric imaging of connective tissue provides insights into the structure of biological tissue. Second harmonic generation (SHG) microscopy has become a standard method to image collagen rich tissue like skin or cornea. Due to the non-centrosymmetric architecture, no additional label is needed and tissue can be visualized noninvasively. Thus, SHG microscopy enables the investigation of collagen associated diseases, providing high resolution images and a field of view of several hundreds of μm. However, the in toto visualization of larger samples is limited to the working distance of the objective and the integration time of the microscope setup, which can sum up to several hours and days. A faster imaging technique for samples in the mesoscopic range is scanning laser optical tomography (SLOT), which provides linear fluorescence, scattering and absorption as intrinsic contrast mechanisms. Due to the advantages of SHG and the reduced measurement time of SLOT, the integration of SHG in SLOT would be a great extension. This way SHG measurements could be performed faster on large samples, providing isotropic resolution and simultaneous acquisition of all other contrast mechanisms available, such as fluorescence and absorption. SLOT is based on the principle of computed tomography, which requires the rotation of the sample. The SHG signal, however, depends strongly on the sample orientation and the polarization of the laser, which results in SHG intensity fluctuation during sample rotation and prevents successful 3D reconstruction. In this paper we investigate the angular dependence of the SHG signal by simulation and experiment and found a way to eliminate reconstruction artifacts caused by this angular dependence in SHG-SLOT data. This way, it is now possible to visualize samples in the mesoscopic range using SHG-SLOT, with isotropic resolution and in correlation to other contrast mechanisms as absorption, fluorescence and scattering. Optical Society of America 2018-05-10 /pmc/articles/PMC6154203/ /pubmed/30258678 http://dx.doi.org/10.1364/BOE.9.002627 Text en © 2018 Optical Society of America under the terms of the OSA Open Access Publishing Agreement © 2018 Optical Society of America under the terms of the OSA Open Access Publishing Agreement (https://doi.org/10.1364/OA_License_v1) |
spellingShingle | Article Nolte, Lena Antonopoulos, Georgios C. Rämisch, Lisa Heisterkamp, Alexander Ripken, Tammo Meyer, Heiko Enabling second harmonic generation as a contrast mechanism for optical projection tomography (OPT) and scanning laser optical tomography (SLOT) |
title | Enabling second harmonic generation as a contrast mechanism for optical projection tomography (OPT) and scanning laser optical tomography (SLOT) |
title_full | Enabling second harmonic generation as a contrast mechanism for optical projection tomography (OPT) and scanning laser optical tomography (SLOT) |
title_fullStr | Enabling second harmonic generation as a contrast mechanism for optical projection tomography (OPT) and scanning laser optical tomography (SLOT) |
title_full_unstemmed | Enabling second harmonic generation as a contrast mechanism for optical projection tomography (OPT) and scanning laser optical tomography (SLOT) |
title_short | Enabling second harmonic generation as a contrast mechanism for optical projection tomography (OPT) and scanning laser optical tomography (SLOT) |
title_sort | enabling second harmonic generation as a contrast mechanism for optical projection tomography (opt) and scanning laser optical tomography (slot) |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6154203/ https://www.ncbi.nlm.nih.gov/pubmed/30258678 http://dx.doi.org/10.1364/BOE.9.002627 |
work_keys_str_mv | AT noltelena enablingsecondharmonicgenerationasacontrastmechanismforopticalprojectiontomographyoptandscanninglaseropticaltomographyslot AT antonopoulosgeorgiosc enablingsecondharmonicgenerationasacontrastmechanismforopticalprojectiontomographyoptandscanninglaseropticaltomographyslot AT ramischlisa enablingsecondharmonicgenerationasacontrastmechanismforopticalprojectiontomographyoptandscanninglaseropticaltomographyslot AT heisterkampalexander enablingsecondharmonicgenerationasacontrastmechanismforopticalprojectiontomographyoptandscanninglaseropticaltomographyslot AT ripkentammo enablingsecondharmonicgenerationasacontrastmechanismforopticalprojectiontomographyoptandscanninglaseropticaltomographyslot AT meyerheiko enablingsecondharmonicgenerationasacontrastmechanismforopticalprojectiontomographyoptandscanninglaseropticaltomographyslot |