Cargando…
Non-fluoroscopic percutaneous transcatheter closure of atrial septal defects in children under transesophageal echocardiographic guidance
BACKGROUND: This study sought to investigate the feasibility, safety and effectiveness of transcatheter closure of atrial septal defects (ASDs) under the guidance of transesophageal echocardiography (TEE) in children. METHODS: We reviewed the medical records of patients who underwent percutaneous AS...
Autores principales: | Xu, Wei-Ze, Shou, Xin-Yi, Li, Jian-Hua, Yu, Jian-Gen, Zhang, Ze-Wei, Yu, Jin, Ye, Jing-Jing |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Childrens Hospital, Zhejiang University School of Medicine
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6154211/ https://www.ncbi.nlm.nih.gov/pubmed/30141110 http://dx.doi.org/10.1007/s12519-018-0179-x |
Ejemplares similares
-
Transesophageal Echocardiographic Images of Atrial Septal Defect Device Closure
por: Raut, Monish S., et al.
Publicado: (2015) -
Echocardiographic Classification and Guidance for Transcatheter Closure of Ventricular Septal Defect
por: Jang, So-Ick, et al.
Publicado: (2021) -
Peratrial Device Closure of Atrial Septal Defect Under
Transesophageal Echocardiographic Guidance without Fluoroscopy Compared to
Conventional On-Pump Surgical Closure
por: Guo, Zhixiang, et al.
Publicado: (2017) -
Percutaneous Retrieval and Redeployment of an Atrial Septal Occluder under Three-Dimensional Transesophageal Echocardiographic Guidance: A Case Report
por: Ahn, Jinhee, et al.
Publicado: (2014) -
Real-time three-dimensional transesophageal echocardiographic guidance versus fluoroscopic guidance for transvenous temporary cardiac pacemaker implantation during transcatheter aortic valve implantation surgeries
por: Cao, Zhongming, et al.
Publicado: (2020)