Safety and Efficacy Outcomes of ZSI 475 Penile Prosthesis

OBJECTIVE: The aim of this study was to demonstrate safety and efficacy of ZSI 475 hydraulic penile prosthesis three components. Preparation, procedure and functional results are similar to AMS 700 and Coloplast Titan. This study was conducted from September 2012 to December 2016. PATIENTS AND METHO...

Descripción completa

Detalles Bibliográficos
Autores principales: Blewniewski, Mariusz, Ostrowski, Ireneusz, Pottek, Tobias, Neugart, Frank, Ciechan, Janusz, Llorens, Christophe, Rozanski, Waldemar
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6154831/
https://www.ncbi.nlm.nih.gov/pubmed/28430342
http://dx.doi.org/10.5301/uj.5000240
_version_ 1783357770800562176
author Blewniewski, Mariusz
Ostrowski, Ireneusz
Pottek, Tobias
Neugart, Frank
Ciechan, Janusz
Llorens, Christophe
Rozanski, Waldemar
author_facet Blewniewski, Mariusz
Ostrowski, Ireneusz
Pottek, Tobias
Neugart, Frank
Ciechan, Janusz
Llorens, Christophe
Rozanski, Waldemar
author_sort Blewniewski, Mariusz
collection PubMed
description OBJECTIVE: The aim of this study was to demonstrate safety and efficacy of ZSI 475 hydraulic penile prosthesis three components. Preparation, procedure and functional results are similar to AMS 700 and Coloplast Titan. This study was conducted from September 2012 to December 2016. PATIENTS AND METHOD: From September 2012 to December 2016, 29 ZSI 475 hydraulic penile prostheses three components were implanted by six surgeons in 28 patients in five European centres. Mean age of patients was 60 years old (44-75). Standard peno-scrotal incision procedure was performed for the 28 patients. Erectile function was assessed by IIEF-5 self-administered questionnaire. RESULTS: Median follow-up was 35.11 months (8-47). Postoperative complications were limited to scrotal pump torsion that required a revision, an armed tubing breakage and a scrotal haematoma. At the end of follow-up, 100% of patients had a functional prosthesis and 92.86% were satisfied. CONCLUSIONS: Implantation, risks of complications, functional outcome and patient satisfaction with penile implant ZSI 475 are similar to standard hydraulic penile implants three components as AMS 700 and Coloplast Titan.
format Online
Article
Text
id pubmed-6154831
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-61548312018-10-11 Safety and Efficacy Outcomes of ZSI 475 Penile Prosthesis Blewniewski, Mariusz Ostrowski, Ireneusz Pottek, Tobias Neugart, Frank Ciechan, Janusz Llorens, Christophe Rozanski, Waldemar Urologia Surgical Technique OBJECTIVE: The aim of this study was to demonstrate safety and efficacy of ZSI 475 hydraulic penile prosthesis three components. Preparation, procedure and functional results are similar to AMS 700 and Coloplast Titan. This study was conducted from September 2012 to December 2016. PATIENTS AND METHOD: From September 2012 to December 2016, 29 ZSI 475 hydraulic penile prostheses three components were implanted by six surgeons in 28 patients in five European centres. Mean age of patients was 60 years old (44-75). Standard peno-scrotal incision procedure was performed for the 28 patients. Erectile function was assessed by IIEF-5 self-administered questionnaire. RESULTS: Median follow-up was 35.11 months (8-47). Postoperative complications were limited to scrotal pump torsion that required a revision, an armed tubing breakage and a scrotal haematoma. At the end of follow-up, 100% of patients had a functional prosthesis and 92.86% were satisfied. CONCLUSIONS: Implantation, risks of complications, functional outcome and patient satisfaction with penile implant ZSI 475 are similar to standard hydraulic penile implants three components as AMS 700 and Coloplast Titan. SAGE Publications 2017-04-20 2017-04 /pmc/articles/PMC6154831/ /pubmed/28430342 http://dx.doi.org/10.5301/uj.5000240 Text en © 2017 SAGE Publications. http://www.creativecommons.org/licenses/by-nc-nd/4.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 License (http://www.creativecommons.org/licenses/by-nc-nd/4.0/) which permits non-commercial use, reproduction and distribution of the work as published without adaptation or alteration, without further permission provided the original work is attributed as specified on the SAGE and Open Access page (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Surgical Technique
Blewniewski, Mariusz
Ostrowski, Ireneusz
Pottek, Tobias
Neugart, Frank
Ciechan, Janusz
Llorens, Christophe
Rozanski, Waldemar
Safety and Efficacy Outcomes of ZSI 475 Penile Prosthesis
title Safety and Efficacy Outcomes of ZSI 475 Penile Prosthesis
title_full Safety and Efficacy Outcomes of ZSI 475 Penile Prosthesis
title_fullStr Safety and Efficacy Outcomes of ZSI 475 Penile Prosthesis
title_full_unstemmed Safety and Efficacy Outcomes of ZSI 475 Penile Prosthesis
title_short Safety and Efficacy Outcomes of ZSI 475 Penile Prosthesis
title_sort safety and efficacy outcomes of zsi 475 penile prosthesis
topic Surgical Technique
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6154831/
https://www.ncbi.nlm.nih.gov/pubmed/28430342
http://dx.doi.org/10.5301/uj.5000240
work_keys_str_mv AT blewniewskimariusz safetyandefficacyoutcomesofzsi475penileprosthesis
AT ostrowskiireneusz safetyandefficacyoutcomesofzsi475penileprosthesis
AT pottektobias safetyandefficacyoutcomesofzsi475penileprosthesis
AT neugartfrank safetyandefficacyoutcomesofzsi475penileprosthesis
AT ciechanjanusz safetyandefficacyoutcomesofzsi475penileprosthesis
AT llorenschristophe safetyandefficacyoutcomesofzsi475penileprosthesis
AT rozanskiwaldemar safetyandefficacyoutcomesofzsi475penileprosthesis