Cargando…
A New Determination Method of the Solubility Parameter of Polymer Based on AIE
An accurate method of the fluorescence probe approach based on an aggregation-induced emission (AIE) molecule (tetraphenylethylene) for measuring the solubility parameter of the polymer is reported. This method is distinctive in that the approach can make the polymer chain conformation in solution b...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6155667/ https://www.ncbi.nlm.nih.gov/pubmed/28042835 http://dx.doi.org/10.3390/molecules22010054 |
_version_ | 1783357942619176960 |
---|---|
author | Jiang, Shan Huang, Tian Ya Wang, Ke Min Tang, Ben Zhong Yu, Qiang |
author_facet | Jiang, Shan Huang, Tian Ya Wang, Ke Min Tang, Ben Zhong Yu, Qiang |
author_sort | Jiang, Shan |
collection | PubMed |
description | An accurate method of the fluorescence probe approach based on an aggregation-induced emission (AIE) molecule (tetraphenylethylene) for measuring the solubility parameter of the polymer is reported. This method is distinctive in that the approach can make the polymer chain conformation in solution be related to the fluorescence intensity. Since the solubility parameter of the polymer is also closely linked to its chain conformation in solution, the solubility parameter can be determined by the fluorescence intensity. The range of the solubility parameter of polymethyl methacrylate (PMMA) tested by this method was from 9.00 cal(1/2)cm(−3/2) to 10.00 cal(1/2)cm(−3/2). The results are more accurate than those obtained from the traditional turbidimetric titration method, ranging from 8.60 cal(1/2)cm(−3/2) to 12.15 cal(1/2)cm(−3/2). According to the photoluminescence (PL) intensities spectra, the solubility parameters of PMMA and polyvinyl acetate (PVAc) are 9.19 cal(1/2)cm(−3/2) and 9.85 cal(1/2)cm(−3/2), respectively. |
format | Online Article Text |
id | pubmed-6155667 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-61556672018-11-13 A New Determination Method of the Solubility Parameter of Polymer Based on AIE Jiang, Shan Huang, Tian Ya Wang, Ke Min Tang, Ben Zhong Yu, Qiang Molecules Communication An accurate method of the fluorescence probe approach based on an aggregation-induced emission (AIE) molecule (tetraphenylethylene) for measuring the solubility parameter of the polymer is reported. This method is distinctive in that the approach can make the polymer chain conformation in solution be related to the fluorescence intensity. Since the solubility parameter of the polymer is also closely linked to its chain conformation in solution, the solubility parameter can be determined by the fluorescence intensity. The range of the solubility parameter of polymethyl methacrylate (PMMA) tested by this method was from 9.00 cal(1/2)cm(−3/2) to 10.00 cal(1/2)cm(−3/2). The results are more accurate than those obtained from the traditional turbidimetric titration method, ranging from 8.60 cal(1/2)cm(−3/2) to 12.15 cal(1/2)cm(−3/2). According to the photoluminescence (PL) intensities spectra, the solubility parameters of PMMA and polyvinyl acetate (PVAc) are 9.19 cal(1/2)cm(−3/2) and 9.85 cal(1/2)cm(−3/2), respectively. MDPI 2016-12-30 /pmc/articles/PMC6155667/ /pubmed/28042835 http://dx.doi.org/10.3390/molecules22010054 Text en © 2016 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Communication Jiang, Shan Huang, Tian Ya Wang, Ke Min Tang, Ben Zhong Yu, Qiang A New Determination Method of the Solubility Parameter of Polymer Based on AIE |
title | A New Determination Method of the Solubility Parameter of Polymer Based on AIE |
title_full | A New Determination Method of the Solubility Parameter of Polymer Based on AIE |
title_fullStr | A New Determination Method of the Solubility Parameter of Polymer Based on AIE |
title_full_unstemmed | A New Determination Method of the Solubility Parameter of Polymer Based on AIE |
title_short | A New Determination Method of the Solubility Parameter of Polymer Based on AIE |
title_sort | new determination method of the solubility parameter of polymer based on aie |
topic | Communication |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6155667/ https://www.ncbi.nlm.nih.gov/pubmed/28042835 http://dx.doi.org/10.3390/molecules22010054 |
work_keys_str_mv | AT jiangshan anewdeterminationmethodofthesolubilityparameterofpolymerbasedonaie AT huangtianya anewdeterminationmethodofthesolubilityparameterofpolymerbasedonaie AT wangkemin anewdeterminationmethodofthesolubilityparameterofpolymerbasedonaie AT tangbenzhong anewdeterminationmethodofthesolubilityparameterofpolymerbasedonaie AT yuqiang anewdeterminationmethodofthesolubilityparameterofpolymerbasedonaie AT jiangshan newdeterminationmethodofthesolubilityparameterofpolymerbasedonaie AT huangtianya newdeterminationmethodofthesolubilityparameterofpolymerbasedonaie AT wangkemin newdeterminationmethodofthesolubilityparameterofpolymerbasedonaie AT tangbenzhong newdeterminationmethodofthesolubilityparameterofpolymerbasedonaie AT yuqiang newdeterminationmethodofthesolubilityparameterofpolymerbasedonaie |