Cargando…
Early hemodynamic performance of the Trifecta™ surgical bioprosthesis aortic valve in Indian patient population: 12 month outcomes of the EVEREST post-market study
BACKGROUND: Indian patients undergoing surgical aortic valve replacement (SAVR) differ from western populations with respect to aortic annulus size and valve disease morphology. The purpose of this post-market, non-randomized observational study was to evaluate the early hemodynamic performance of t...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6157043/ https://www.ncbi.nlm.nih.gov/pubmed/30253784 http://dx.doi.org/10.1186/s13019-018-0783-9 |
Sumario: | BACKGROUND: Indian patients undergoing surgical aortic valve replacement (SAVR) differ from western populations with respect to aortic annulus size and valve disease morphology. The purpose of this post-market, non-randomized observational study was to evaluate the early hemodynamic performance of the Trifecta™ bioprosthesis (Abbott, previously St. Jude Medical, Minneapolis, US) in an Indian patient population. METHODS: From January 2014 to September 2015, 100 patients (mean age 64.4 ± 7.1 years, 62% male) undergoing SAVR for valve disease (68% stenosis, 7% insufficiency, 25% mixed pathology) were enrolled across 10 centers in India. Patients implanted with a 19–27 mm Trifecta™ valve were eligible to participate and were prospectively followed for 12-months post-implantation. Echocardiographic hemodynamic performance was evaluated at pre-implant, pre-discharge and at 12-months by an independent core laboratory. Adverse events were adjudicated by the study sponsor. Functional status at 12-months was assessed according to NYHA classification. Continuous data was summarized using descriptive statistics (mean &standard deviation,) and categorical data was summarized using frequencies and percentages. RESULT: Ninety patients (mean age 64.5, 62.2% male) completed the 12-month follow up. Significant improvements in hemodynamic valve performance were reported in 81 patients with available echocardiographic data at 12 months. Compared to baseline at 12-month follow up visit, mean effective orifice area increased from 0.75cm(2) to 1.61cm(2) (p < 0.0001), mean pressure gradient reduced to 10.42 mmHg from 51.47 mmHg (p < 0.0001), cardiac output increased from 4.46 l/min to 4.85 l/min (P 0.9254). Compared to baseline, functional status improved by ≥1 NYHA class in 75% of patients at 12 months (95% Clopper-Pearson (Exact) confidence limit [64.6%, 83.6%]). No instances of early mortality (< 30 days from index procedure) or structural valve dysfunction were reported. CONCLUSION: In an Indian patient population, implantation of the Trifecta™ bioprosthesis is shown to be safe and associated with favorable early hemodynamic performance and improved functional status at 12 months. TRIAL REGISTRATION: The clinical study has been registered under Clinical Trial Registry-India (http://www.ctri.nic.in) and registration number is CTRI/2014/02/004434 registered on 25 February 2014 retrospectively registered. |
---|