Cargando…

Osseointegrated Transcutaneous Device for Amputees: A Pilot Large Animal Model

Traditional above-the-knee amputation prosthetics utilize a stump-socket interface that is well-known for skin/socket problems, sitting difficulty, disuse osteopenia, and increased work of ambulation. As a result, we evaluated a novel osseointegrated transcutaneous implant in a large animal. The imp...

Descripción completa

Detalles Bibliográficos
Autores principales: Grisez, Brian T., Hanselman, Andrew E., Boukhemis, Karim W., Lalli, Trapper A. J., Lindsey, Brock A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6158950/
https://www.ncbi.nlm.nih.gov/pubmed/30302292
http://dx.doi.org/10.1155/2018/4625967
_version_ 1783358523602632704
author Grisez, Brian T.
Hanselman, Andrew E.
Boukhemis, Karim W.
Lalli, Trapper A. J.
Lindsey, Brock A.
author_facet Grisez, Brian T.
Hanselman, Andrew E.
Boukhemis, Karim W.
Lalli, Trapper A. J.
Lindsey, Brock A.
author_sort Grisez, Brian T.
collection PubMed
description Traditional above-the-knee amputation prosthetics utilize a stump-socket interface that is well-known for skin/socket problems, sitting difficulty, disuse osteopenia, and increased work of ambulation. As a result, we evaluated a novel osseointegrated transcutaneous implant in a large animal. The implant was designed to promote osseointegration at the bone-implant interface and minimize complications. As proof of concept, four Dorset sheep underwent a two-stage surgery for forelimb placement of an osseointegrated transcutaneous implant utilizing Compress® technology (Biomet, Inc., Warsaw, IN). Two sheep received a long anchor plug (90 mm long x 9 mm in diameter) and two received a short anchor plug (46 mm long x 9 mm in diameter). Sixteen weeks after the initial surgery, the operative limbs, along with the attached implant, underwent radiographic and histological analysis for osseointegration. Periprosthetic fractures occurred in the two animals that received the longer internal prosthesis; one healed with splinting and the other animal underwent a second surgical procedure to advance the amputation site more proximal. No fractures occurred in the shorter internal prosthesis group. There was no histological evidence of infection and none of the transcutaneous adapters failed. Bone-implant osseointegration was demonstrated in two of three limbs that underwent histological analysis. This unique implant demonstrated osseointegration without transcutaneous adapter failure, all while displaying minimal infection risk from the outside environment. Although it involved short-term follow-up in a limited number of animals, this pilot study provides a platform for further investigation into the valid concept of using Compress® technology as an endo-exo device.
format Online
Article
Text
id pubmed-6158950
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-61589502018-10-09 Osseointegrated Transcutaneous Device for Amputees: A Pilot Large Animal Model Grisez, Brian T. Hanselman, Andrew E. Boukhemis, Karim W. Lalli, Trapper A. J. Lindsey, Brock A. Adv Orthop Research Article Traditional above-the-knee amputation prosthetics utilize a stump-socket interface that is well-known for skin/socket problems, sitting difficulty, disuse osteopenia, and increased work of ambulation. As a result, we evaluated a novel osseointegrated transcutaneous implant in a large animal. The implant was designed to promote osseointegration at the bone-implant interface and minimize complications. As proof of concept, four Dorset sheep underwent a two-stage surgery for forelimb placement of an osseointegrated transcutaneous implant utilizing Compress® technology (Biomet, Inc., Warsaw, IN). Two sheep received a long anchor plug (90 mm long x 9 mm in diameter) and two received a short anchor plug (46 mm long x 9 mm in diameter). Sixteen weeks after the initial surgery, the operative limbs, along with the attached implant, underwent radiographic and histological analysis for osseointegration. Periprosthetic fractures occurred in the two animals that received the longer internal prosthesis; one healed with splinting and the other animal underwent a second surgical procedure to advance the amputation site more proximal. No fractures occurred in the shorter internal prosthesis group. There was no histological evidence of infection and none of the transcutaneous adapters failed. Bone-implant osseointegration was demonstrated in two of three limbs that underwent histological analysis. This unique implant demonstrated osseointegration without transcutaneous adapter failure, all while displaying minimal infection risk from the outside environment. Although it involved short-term follow-up in a limited number of animals, this pilot study provides a platform for further investigation into the valid concept of using Compress® technology as an endo-exo device. Hindawi 2018-09-13 /pmc/articles/PMC6158950/ /pubmed/30302292 http://dx.doi.org/10.1155/2018/4625967 Text en Copyright © 2018 Brian T. Grisez et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Grisez, Brian T.
Hanselman, Andrew E.
Boukhemis, Karim W.
Lalli, Trapper A. J.
Lindsey, Brock A.
Osseointegrated Transcutaneous Device for Amputees: A Pilot Large Animal Model
title Osseointegrated Transcutaneous Device for Amputees: A Pilot Large Animal Model
title_full Osseointegrated Transcutaneous Device for Amputees: A Pilot Large Animal Model
title_fullStr Osseointegrated Transcutaneous Device for Amputees: A Pilot Large Animal Model
title_full_unstemmed Osseointegrated Transcutaneous Device for Amputees: A Pilot Large Animal Model
title_short Osseointegrated Transcutaneous Device for Amputees: A Pilot Large Animal Model
title_sort osseointegrated transcutaneous device for amputees: a pilot large animal model
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6158950/
https://www.ncbi.nlm.nih.gov/pubmed/30302292
http://dx.doi.org/10.1155/2018/4625967
work_keys_str_mv AT grisezbriant osseointegratedtranscutaneousdeviceforamputeesapilotlargeanimalmodel
AT hanselmanandrewe osseointegratedtranscutaneousdeviceforamputeesapilotlargeanimalmodel
AT boukhemiskarimw osseointegratedtranscutaneousdeviceforamputeesapilotlargeanimalmodel
AT lallitrapperaj osseointegratedtranscutaneousdeviceforamputeesapilotlargeanimalmodel
AT lindseybrocka osseointegratedtranscutaneousdeviceforamputeesapilotlargeanimalmodel