Cargando…

Contrast media-assisted in-treatment cone beam CT during single-isocentre volumetric-modulated arc therapy for multiple brain metastases: a case study

A direct visualization technique for verifying intrafractional localization accuracy of multiple brain metastases during single-isocentre volumetric-modulated arc therapy has been proposed using contrast media-assisted in-treatment cone beam CT (CBCT). Contrast-enhanced planning CT images were acqui...

Descripción completa

Detalles Bibliográficos
Autores principales: Nomoto, Akihiro K, Takahashi, Wataru, Yamashita, Hideomi, Haga, Akihiro, Yoda, Kiyoshi, Nakagawa, Keiichi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The British Institute of Radiology 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6159277/
https://www.ncbi.nlm.nih.gov/pubmed/30363248
http://dx.doi.org/10.1259/bjrcr.20160088
_version_ 1783358596028825600
author Nomoto, Akihiro K
Takahashi, Wataru
Yamashita, Hideomi
Haga, Akihiro
Yoda, Kiyoshi
Nakagawa, Keiichi
author_facet Nomoto, Akihiro K
Takahashi, Wataru
Yamashita, Hideomi
Haga, Akihiro
Yoda, Kiyoshi
Nakagawa, Keiichi
author_sort Nomoto, Akihiro K
collection PubMed
description A direct visualization technique for verifying intrafractional localization accuracy of multiple brain metastases during single-isocentre volumetric-modulated arc therapy has been proposed using contrast media-assisted in-treatment cone beam CT (CBCT). Contrast-enhanced planning CT images were acquired immediately after intravenous bolus administration of iodized contrast media at a dose of 2 ml kg(–1). Out of 41 nodules detected on the images, 8 lesions were contoured as high-risk gross tumour volumes (GTVs). Prior to each treatment, CBCT imaging was performed to match the skull structures with the planning CT images. Immediately after another intravenous bolus injection of the iodized contrast media at the same dose as administered for the planning CT imaging, contrast-enhanced CBCT images were acquired during volumetric-modulated arc therapy delivery, thereby providing direct verification of time-averaged tumour position during treatment. The planning target volume contours were overlaid with the in-treatment CBCT images, thereby allowing us to directly visualize the localization accuracy of each GTV when the beam delivery was completed. It was visually confirmed that each GTV was accurately localized inside each planning target volume during beam delivery.
format Online
Article
Text
id pubmed-6159277
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher The British Institute of Radiology
record_format MEDLINE/PubMed
spelling pubmed-61592772018-10-25 Contrast media-assisted in-treatment cone beam CT during single-isocentre volumetric-modulated arc therapy for multiple brain metastases: a case study Nomoto, Akihiro K Takahashi, Wataru Yamashita, Hideomi Haga, Akihiro Yoda, Kiyoshi Nakagawa, Keiichi BJR Case Rep Technical Note A direct visualization technique for verifying intrafractional localization accuracy of multiple brain metastases during single-isocentre volumetric-modulated arc therapy has been proposed using contrast media-assisted in-treatment cone beam CT (CBCT). Contrast-enhanced planning CT images were acquired immediately after intravenous bolus administration of iodized contrast media at a dose of 2 ml kg(–1). Out of 41 nodules detected on the images, 8 lesions were contoured as high-risk gross tumour volumes (GTVs). Prior to each treatment, CBCT imaging was performed to match the skull structures with the planning CT images. Immediately after another intravenous bolus injection of the iodized contrast media at the same dose as administered for the planning CT imaging, contrast-enhanced CBCT images were acquired during volumetric-modulated arc therapy delivery, thereby providing direct verification of time-averaged tumour position during treatment. The planning target volume contours were overlaid with the in-treatment CBCT images, thereby allowing us to directly visualize the localization accuracy of each GTV when the beam delivery was completed. It was visually confirmed that each GTV was accurately localized inside each planning target volume during beam delivery. The British Institute of Radiology 2016-09-07 /pmc/articles/PMC6159277/ /pubmed/30363248 http://dx.doi.org/10.1259/bjrcr.20160088 Text en © 2016 The Authors. Published by the British Institute of Radiology http://creativecommons.org/licenses/by/4.0/ This is an open access article under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution and reproduction in any medium, provided the original author and source are credited.
spellingShingle Technical Note
Nomoto, Akihiro K
Takahashi, Wataru
Yamashita, Hideomi
Haga, Akihiro
Yoda, Kiyoshi
Nakagawa, Keiichi
Contrast media-assisted in-treatment cone beam CT during single-isocentre volumetric-modulated arc therapy for multiple brain metastases: a case study
title Contrast media-assisted in-treatment cone beam CT during single-isocentre volumetric-modulated arc therapy for multiple brain metastases: a case study
title_full Contrast media-assisted in-treatment cone beam CT during single-isocentre volumetric-modulated arc therapy for multiple brain metastases: a case study
title_fullStr Contrast media-assisted in-treatment cone beam CT during single-isocentre volumetric-modulated arc therapy for multiple brain metastases: a case study
title_full_unstemmed Contrast media-assisted in-treatment cone beam CT during single-isocentre volumetric-modulated arc therapy for multiple brain metastases: a case study
title_short Contrast media-assisted in-treatment cone beam CT during single-isocentre volumetric-modulated arc therapy for multiple brain metastases: a case study
title_sort contrast media-assisted in-treatment cone beam ct during single-isocentre volumetric-modulated arc therapy for multiple brain metastases: a case study
topic Technical Note
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6159277/
https://www.ncbi.nlm.nih.gov/pubmed/30363248
http://dx.doi.org/10.1259/bjrcr.20160088
work_keys_str_mv AT nomotoakihirok contrastmediaassistedintreatmentconebeamctduringsingleisocentrevolumetricmodulatedarctherapyformultiplebrainmetastasesacasestudy
AT takahashiwataru contrastmediaassistedintreatmentconebeamctduringsingleisocentrevolumetricmodulatedarctherapyformultiplebrainmetastasesacasestudy
AT yamashitahideomi contrastmediaassistedintreatmentconebeamctduringsingleisocentrevolumetricmodulatedarctherapyformultiplebrainmetastasesacasestudy
AT hagaakihiro contrastmediaassistedintreatmentconebeamctduringsingleisocentrevolumetricmodulatedarctherapyformultiplebrainmetastasesacasestudy
AT yodakiyoshi contrastmediaassistedintreatmentconebeamctduringsingleisocentrevolumetricmodulatedarctherapyformultiplebrainmetastasesacasestudy
AT nakagawakeiichi contrastmediaassistedintreatmentconebeamctduringsingleisocentrevolumetricmodulatedarctherapyformultiplebrainmetastasesacasestudy