The Use of a Virtual Patient to Follow Pleural Pressure Changes Associated with Therapeutic Thoracentesis

PURPOSE: Influence of therapeutic thoracentesis on the pleural pressure (Pp) has been discussed in many clinical studies, however reasons of Pp changes are not precisely established. The aim of the study was to use a previously elaborated virtual cardiopulmonary patient (VP) in analysis of impact of...

Descripción completa

Detalles Bibliográficos
Autores principales: Gólczewski, Tomasz, Stecka, Anna M., Michnikowski, Marcin, Grabczak, Elżbieta M., Korczyński, Piotr, Krenke, Rafał
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6161568/
https://www.ncbi.nlm.nih.gov/pubmed/28799625
http://dx.doi.org/10.5301/ijao.5000636
_version_ 1783359013721735168
author Gólczewski, Tomasz
Stecka, Anna M.
Michnikowski, Marcin
Grabczak, Elżbieta M.
Korczyński, Piotr
Krenke, Rafał
author_facet Gólczewski, Tomasz
Stecka, Anna M.
Michnikowski, Marcin
Grabczak, Elżbieta M.
Korczyński, Piotr
Krenke, Rafał
author_sort Gólczewski, Tomasz
collection PubMed
description PURPOSE: Influence of therapeutic thoracentesis on the pleural pressure (Pp) has been discussed in many clinical studies, however reasons of Pp changes are not precisely established. The aim of the study was to use a previously elaborated virtual cardiopulmonary patient (VP) in analysis of impact of physiological factors on Pp during the procedure. METHODS: Simulations were performed on VP with default values of parameters for which VP simulated the respiratory system of the average 50-year-old healthy Polish woman according to spirometric examination. Alterations of Pp and the amplitude of Pp changes related to breathing (AP) were analyzed. Model parameters related to chosen factors were deviated from their default values to analyze the degree of their impact on Pp and AP. The analysis was based on and supported by our own clinical data. RESULTS: The Pp and AP alteration intensity appeared to be most sensitive to the compliances of the rib cage and mediastinum, and the nonlinearity of the dependence between the recoil pressure and the lung volume: the lower the compliances and the higher the nonlinearity were, the deeper the Pp fall during the procedure and the bigger the AP increase were observed. CONCLUSIONS: Experiments in silico are very useful in analyzing sophisticated physiological and medical problems. They made it possible to show which factors are particularly responsible for changes in Pp during thoracentesis. In the future, they may be useful in establishing objective conditions under which thoracentesis needs to be stopped.
format Online
Article
Text
id pubmed-6161568
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-61615682020-09-02 The Use of a Virtual Patient to Follow Pleural Pressure Changes Associated with Therapeutic Thoracentesis Gólczewski, Tomasz Stecka, Anna M. Michnikowski, Marcin Grabczak, Elżbieta M. Korczyński, Piotr Krenke, Rafał Int J Artif Organs Original Research Article PURPOSE: Influence of therapeutic thoracentesis on the pleural pressure (Pp) has been discussed in many clinical studies, however reasons of Pp changes are not precisely established. The aim of the study was to use a previously elaborated virtual cardiopulmonary patient (VP) in analysis of impact of physiological factors on Pp during the procedure. METHODS: Simulations were performed on VP with default values of parameters for which VP simulated the respiratory system of the average 50-year-old healthy Polish woman according to spirometric examination. Alterations of Pp and the amplitude of Pp changes related to breathing (AP) were analyzed. Model parameters related to chosen factors were deviated from their default values to analyze the degree of their impact on Pp and AP. The analysis was based on and supported by our own clinical data. RESULTS: The Pp and AP alteration intensity appeared to be most sensitive to the compliances of the rib cage and mediastinum, and the nonlinearity of the dependence between the recoil pressure and the lung volume: the lower the compliances and the higher the nonlinearity were, the deeper the Pp fall during the procedure and the bigger the AP increase were observed. CONCLUSIONS: Experiments in silico are very useful in analyzing sophisticated physiological and medical problems. They made it possible to show which factors are particularly responsible for changes in Pp during thoracentesis. In the future, they may be useful in establishing objective conditions under which thoracentesis needs to be stopped. SAGE Publications 2018-01-10 2017-12 /pmc/articles/PMC6161568/ /pubmed/28799625 http://dx.doi.org/10.5301/ijao.5000636 Text en © 2017 SAGE Publications http://www.creativecommons.org/licenses/by-nc-nd/4.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 License (http://www.creativecommons.org/licenses/by-nc-nd/4.0/) which permits non-commercial use, reproduction and distribution of the work as published without adaptation or alteration, without further permission provided the original work is attributed as specified on the SAGE and Open Access page (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Original Research Article
Gólczewski, Tomasz
Stecka, Anna M.
Michnikowski, Marcin
Grabczak, Elżbieta M.
Korczyński, Piotr
Krenke, Rafał
The Use of a Virtual Patient to Follow Pleural Pressure Changes Associated with Therapeutic Thoracentesis
title The Use of a Virtual Patient to Follow Pleural Pressure Changes Associated with Therapeutic Thoracentesis
title_full The Use of a Virtual Patient to Follow Pleural Pressure Changes Associated with Therapeutic Thoracentesis
title_fullStr The Use of a Virtual Patient to Follow Pleural Pressure Changes Associated with Therapeutic Thoracentesis
title_full_unstemmed The Use of a Virtual Patient to Follow Pleural Pressure Changes Associated with Therapeutic Thoracentesis
title_short The Use of a Virtual Patient to Follow Pleural Pressure Changes Associated with Therapeutic Thoracentesis
title_sort use of a virtual patient to follow pleural pressure changes associated with therapeutic thoracentesis
topic Original Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6161568/
https://www.ncbi.nlm.nih.gov/pubmed/28799625
http://dx.doi.org/10.5301/ijao.5000636
work_keys_str_mv AT golczewskitomasz theuseofavirtualpatienttofollowpleuralpressurechangesassociatedwiththerapeuticthoracentesis
AT steckaannam theuseofavirtualpatienttofollowpleuralpressurechangesassociatedwiththerapeuticthoracentesis
AT michnikowskimarcin theuseofavirtualpatienttofollowpleuralpressurechangesassociatedwiththerapeuticthoracentesis
AT grabczakelzbietam theuseofavirtualpatienttofollowpleuralpressurechangesassociatedwiththerapeuticthoracentesis
AT korczynskipiotr theuseofavirtualpatienttofollowpleuralpressurechangesassociatedwiththerapeuticthoracentesis
AT krenkerafał theuseofavirtualpatienttofollowpleuralpressurechangesassociatedwiththerapeuticthoracentesis
AT golczewskitomasz useofavirtualpatienttofollowpleuralpressurechangesassociatedwiththerapeuticthoracentesis
AT steckaannam useofavirtualpatienttofollowpleuralpressurechangesassociatedwiththerapeuticthoracentesis
AT michnikowskimarcin useofavirtualpatienttofollowpleuralpressurechangesassociatedwiththerapeuticthoracentesis
AT grabczakelzbietam useofavirtualpatienttofollowpleuralpressurechangesassociatedwiththerapeuticthoracentesis
AT korczynskipiotr useofavirtualpatienttofollowpleuralpressurechangesassociatedwiththerapeuticthoracentesis
AT krenkerafał useofavirtualpatienttofollowpleuralpressurechangesassociatedwiththerapeuticthoracentesis