Cargando…

Biomechanical properties of adjustable extracortical graft fixations in ACL reconstruction

BACKGROUND: Reliable biomechanical data about the strength of different tibial extracortical graft fixation devices is sparse. This biomechanical study compares the properties of tibial graft fixation in ACL reconstruction with either the ACL Tight Rope™ or the Rigid Loop Adjustable™ device. The hyp...

Descripción completa

Detalles Bibliográficos
Autores principales: Ettinger, M., Karkosch, R., Horstmann, H., Savov, P., Calliess, T., Smith, T., Petri, M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6163122/
https://www.ncbi.nlm.nih.gov/pubmed/30269194
http://dx.doi.org/10.1186/s40634-018-0154-4
_version_ 1783359285746466816
author Ettinger, M.
Karkosch, R.
Horstmann, H.
Savov, P.
Calliess, T.
Smith, T.
Petri, M.
author_facet Ettinger, M.
Karkosch, R.
Horstmann, H.
Savov, P.
Calliess, T.
Smith, T.
Petri, M.
author_sort Ettinger, M.
collection PubMed
description BACKGROUND: Reliable biomechanical data about the strength of different tibial extracortical graft fixation devices is sparse. This biomechanical study compares the properties of tibial graft fixation in ACL reconstruction with either the ACL Tight Rope™ or the Rigid Loop Adjustable™ device. The hypothesis was that both fixation devices would provide comparable results concerning gap formation during cyclic loading and ultimate failure load. METHODS: Sixteen sawbone tibiae (Sawbones™) underwent extracortical fixation of porcine flexor digitorum profundus grafts for ACL reconstruction. Either the ACL Tight Rope™ (Arthrex) or the Rigid Loop Adjustable™ (DePuy Mitek) fixation device were used, resulting in 2 groups with 8 specimens per group. Biomechanical analysis included pretensioning the constructs 10 times with 0.75 Hz, then cyclic loading of 1,000 position-controlled cycles and 1,000 force-controlled cycles applied with a servohydraulic testing machine. Elongation during cyclic loading was recorded. After this, ultimate failure load and failure mode analysis were performed. RESULTS: No statistically significant difference could be noted between the groups regarding gap formation during cyclic loading (4.6 ± 2.6 mm for the Rigid Loop Adjustable™ vs. 6.6 ± 1.5 mm for the ACL Tight Rope™ (p > 0.05)), and ultimate failure loads (980 ± 101.9 N for the Rigid Loop Adjustable™ vs. 861 ± 115 N ACL Tight Rope™ (p > 0.05)). CONCLUSION: ACL Tight Rope™ and the Rigid Loop Adjustable™ fixation devices yield comparable biomechanical results for tibial extracortical graft fixation in ACL reconstruction. These findings may be of relevance for the future surgical decision-making in ACL reconstruction. Randomized controlled clinical trials comparing both fixation devices are desirable for the future.
format Online
Article
Text
id pubmed-6163122
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-61631222018-10-09 Biomechanical properties of adjustable extracortical graft fixations in ACL reconstruction Ettinger, M. Karkosch, R. Horstmann, H. Savov, P. Calliess, T. Smith, T. Petri, M. J Exp Orthop Research BACKGROUND: Reliable biomechanical data about the strength of different tibial extracortical graft fixation devices is sparse. This biomechanical study compares the properties of tibial graft fixation in ACL reconstruction with either the ACL Tight Rope™ or the Rigid Loop Adjustable™ device. The hypothesis was that both fixation devices would provide comparable results concerning gap formation during cyclic loading and ultimate failure load. METHODS: Sixteen sawbone tibiae (Sawbones™) underwent extracortical fixation of porcine flexor digitorum profundus grafts for ACL reconstruction. Either the ACL Tight Rope™ (Arthrex) or the Rigid Loop Adjustable™ (DePuy Mitek) fixation device were used, resulting in 2 groups with 8 specimens per group. Biomechanical analysis included pretensioning the constructs 10 times with 0.75 Hz, then cyclic loading of 1,000 position-controlled cycles and 1,000 force-controlled cycles applied with a servohydraulic testing machine. Elongation during cyclic loading was recorded. After this, ultimate failure load and failure mode analysis were performed. RESULTS: No statistically significant difference could be noted between the groups regarding gap formation during cyclic loading (4.6 ± 2.6 mm for the Rigid Loop Adjustable™ vs. 6.6 ± 1.5 mm for the ACL Tight Rope™ (p > 0.05)), and ultimate failure loads (980 ± 101.9 N for the Rigid Loop Adjustable™ vs. 861 ± 115 N ACL Tight Rope™ (p > 0.05)). CONCLUSION: ACL Tight Rope™ and the Rigid Loop Adjustable™ fixation devices yield comparable biomechanical results for tibial extracortical graft fixation in ACL reconstruction. These findings may be of relevance for the future surgical decision-making in ACL reconstruction. Randomized controlled clinical trials comparing both fixation devices are desirable for the future. Springer Berlin Heidelberg 2018-09-29 /pmc/articles/PMC6163122/ /pubmed/30269194 http://dx.doi.org/10.1186/s40634-018-0154-4 Text en © The Author(s). 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Research
Ettinger, M.
Karkosch, R.
Horstmann, H.
Savov, P.
Calliess, T.
Smith, T.
Petri, M.
Biomechanical properties of adjustable extracortical graft fixations in ACL reconstruction
title Biomechanical properties of adjustable extracortical graft fixations in ACL reconstruction
title_full Biomechanical properties of adjustable extracortical graft fixations in ACL reconstruction
title_fullStr Biomechanical properties of adjustable extracortical graft fixations in ACL reconstruction
title_full_unstemmed Biomechanical properties of adjustable extracortical graft fixations in ACL reconstruction
title_short Biomechanical properties of adjustable extracortical graft fixations in ACL reconstruction
title_sort biomechanical properties of adjustable extracortical graft fixations in acl reconstruction
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6163122/
https://www.ncbi.nlm.nih.gov/pubmed/30269194
http://dx.doi.org/10.1186/s40634-018-0154-4
work_keys_str_mv AT ettingerm biomechanicalpropertiesofadjustableextracorticalgraftfixationsinaclreconstruction
AT karkoschr biomechanicalpropertiesofadjustableextracorticalgraftfixationsinaclreconstruction
AT horstmannh biomechanicalpropertiesofadjustableextracorticalgraftfixationsinaclreconstruction
AT savovp biomechanicalpropertiesofadjustableextracorticalgraftfixationsinaclreconstruction
AT calliesst biomechanicalpropertiesofadjustableextracorticalgraftfixationsinaclreconstruction
AT smitht biomechanicalpropertiesofadjustableextracorticalgraftfixationsinaclreconstruction
AT petrim biomechanicalpropertiesofadjustableextracorticalgraftfixationsinaclreconstruction
AT biomechanicalpropertiesofadjustableextracorticalgraftfixationsinaclreconstruction