Improvement of Ultrasonic Pulse Generator for Automatic Pipeline Inspection
This paper presents the improvement of an ultrasonic pulse generator for a pipeline inspection gauge (PIG), which uses 64 transducers for inspecting distances up to 100 km with an axial resolution fixed at 3 mm and variable speeds between 0 and 2 m/s. An ultrasonic pulse generator is composed of a h...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6163491/ https://www.ncbi.nlm.nih.gov/pubmed/30189628 http://dx.doi.org/10.3390/s18092950 |
_version_ | 1783359373903396864 |
---|---|
author | Rodríguez-Olivares, Noé Amir Cruz-Cruz, José Vicente Gómez-Hernández, Alejandro Hernández-Alvarado, Rodrigo Nava-Balanzar, Luciano Salgado-Jiménez, Tomás Soto-Cajiga, Jorge Alberto |
author_facet | Rodríguez-Olivares, Noé Amir Cruz-Cruz, José Vicente Gómez-Hernández, Alejandro Hernández-Alvarado, Rodrigo Nava-Balanzar, Luciano Salgado-Jiménez, Tomás Soto-Cajiga, Jorge Alberto |
author_sort | Rodríguez-Olivares, Noé Amir |
collection | PubMed |
description | This paper presents the improvement of an ultrasonic pulse generator for a pipeline inspection gauge (PIG), which uses 64 transducers for inspecting distances up to 100 km with an axial resolution fixed at 3 mm and variable speeds between 0 and 2 m/s. An ultrasonic pulse generator is composed of a high-voltage (HV) MOSFETs, driver logic and an HV power supply. We used a DC-HV DC converter device as the HV power supply because it reduces the size of the ultrasound system considerably. However, pipeline geometry and inspection effects such as hammer and shock cause a variable pulse repetition frequency (PRF), producing voltage drops, poor quality of the HV pulse generated, failures in the dimensioning of defects and damage to devices by over-voltage. Our improvement is to implement a control scheme to maintain the high quality of the HV regardless of the variable PRF. To achieve this, we characterized three transfer functions of the DC-HV DC converter, varying the connected load to 10%, 45% and 80%. For the characterization, we used the least squares technique, considering an autoregressive exogenous (ARX) model. Later, we compared three control schemes: (1) proportional-integral-derivative (PID) tuned by simultaneous optimization of several responses (SOSR), (2) PID tuned by a neural network (NN) and (3) PI tuned by the analytical design method (ADM). The metrics used to compare the control schemes were the recovery time, the maximum over-voltage and the excess energy when the shock and hammer effects happen to occur. Finally, to verify the improvement of the HV pulser, we compared the ultrasonic pulses generated for various frequencies and amplitudes using the pulse generator with and without the control scheme. |
format | Online Article Text |
id | pubmed-6163491 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-61634912018-10-10 Improvement of Ultrasonic Pulse Generator for Automatic Pipeline Inspection Rodríguez-Olivares, Noé Amir Cruz-Cruz, José Vicente Gómez-Hernández, Alejandro Hernández-Alvarado, Rodrigo Nava-Balanzar, Luciano Salgado-Jiménez, Tomás Soto-Cajiga, Jorge Alberto Sensors (Basel) Article This paper presents the improvement of an ultrasonic pulse generator for a pipeline inspection gauge (PIG), which uses 64 transducers for inspecting distances up to 100 km with an axial resolution fixed at 3 mm and variable speeds between 0 and 2 m/s. An ultrasonic pulse generator is composed of a high-voltage (HV) MOSFETs, driver logic and an HV power supply. We used a DC-HV DC converter device as the HV power supply because it reduces the size of the ultrasound system considerably. However, pipeline geometry and inspection effects such as hammer and shock cause a variable pulse repetition frequency (PRF), producing voltage drops, poor quality of the HV pulse generated, failures in the dimensioning of defects and damage to devices by over-voltage. Our improvement is to implement a control scheme to maintain the high quality of the HV regardless of the variable PRF. To achieve this, we characterized three transfer functions of the DC-HV DC converter, varying the connected load to 10%, 45% and 80%. For the characterization, we used the least squares technique, considering an autoregressive exogenous (ARX) model. Later, we compared three control schemes: (1) proportional-integral-derivative (PID) tuned by simultaneous optimization of several responses (SOSR), (2) PID tuned by a neural network (NN) and (3) PI tuned by the analytical design method (ADM). The metrics used to compare the control schemes were the recovery time, the maximum over-voltage and the excess energy when the shock and hammer effects happen to occur. Finally, to verify the improvement of the HV pulser, we compared the ultrasonic pulses generated for various frequencies and amplitudes using the pulse generator with and without the control scheme. MDPI 2018-09-05 /pmc/articles/PMC6163491/ /pubmed/30189628 http://dx.doi.org/10.3390/s18092950 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Rodríguez-Olivares, Noé Amir Cruz-Cruz, José Vicente Gómez-Hernández, Alejandro Hernández-Alvarado, Rodrigo Nava-Balanzar, Luciano Salgado-Jiménez, Tomás Soto-Cajiga, Jorge Alberto Improvement of Ultrasonic Pulse Generator for Automatic Pipeline Inspection |
title | Improvement of Ultrasonic Pulse Generator for Automatic Pipeline Inspection |
title_full | Improvement of Ultrasonic Pulse Generator for Automatic Pipeline Inspection |
title_fullStr | Improvement of Ultrasonic Pulse Generator for Automatic Pipeline Inspection |
title_full_unstemmed | Improvement of Ultrasonic Pulse Generator for Automatic Pipeline Inspection |
title_short | Improvement of Ultrasonic Pulse Generator for Automatic Pipeline Inspection |
title_sort | improvement of ultrasonic pulse generator for automatic pipeline inspection |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6163491/ https://www.ncbi.nlm.nih.gov/pubmed/30189628 http://dx.doi.org/10.3390/s18092950 |
work_keys_str_mv | AT rodriguezolivaresnoeamir improvementofultrasonicpulsegeneratorforautomaticpipelineinspection AT cruzcruzjosevicente improvementofultrasonicpulsegeneratorforautomaticpipelineinspection AT gomezhernandezalejandro improvementofultrasonicpulsegeneratorforautomaticpipelineinspection AT hernandezalvaradorodrigo improvementofultrasonicpulsegeneratorforautomaticpipelineinspection AT navabalanzarluciano improvementofultrasonicpulsegeneratorforautomaticpipelineinspection AT salgadojimeneztomas improvementofultrasonicpulsegeneratorforautomaticpipelineinspection AT sotocajigajorgealberto improvementofultrasonicpulsegeneratorforautomaticpipelineinspection |