Cargando…
Design and Evaluation of a MEMS Magnetic Field Sensor-Based Respiratory Monitoring and Training System for Radiotherapy
The patient’s respiratory pattern and reproducibility are important factors affecting the accuracy of radiotherapy for lung cancer or liver cancer cases. Therefore, respiration training is required to induce respiration regularity before radiotherapy. However, the need for specialized personnel, spa...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6163714/ https://www.ncbi.nlm.nih.gov/pubmed/30134526 http://dx.doi.org/10.3390/s18092742 |
_version_ | 1783359427632431104 |
---|---|
author | Oh, Yoonjin Jung, Young-Jin Choi, Sang Hyoun Kim, Dong Wook |
author_facet | Oh, Yoonjin Jung, Young-Jin Choi, Sang Hyoun Kim, Dong Wook |
author_sort | Oh, Yoonjin |
collection | PubMed |
description | The patient’s respiratory pattern and reproducibility are important factors affecting the accuracy of radiotherapy for lung cancer or liver cancer cases. Therefore, respiration training is required to induce respiration regularity before radiotherapy. However, the need for specialized personnel, space, and time-consuming training represent limitations. To solve these problems, we have developed a respiratory monitoring and training system based on a micro-electro-mechanical-system (MEMS) magnetic sensor. This system consists of a small attaching magnet, a sensor, and a breathing pattern output device. In this study, we evaluated the performance of the signal measurement in the developed system based on the various respiratory cycles, the amplitudes, and the position angles of the magnet and the sensor. The system can provide a more accurate breathing signal graph with lower measurement error and higher spatial resolution than conventional sensor methods by using additional magnet. In addition, it is possible the patient to monitor and train breathing himself by making it easy to carry and use without restriction of time and space. |
format | Online Article Text |
id | pubmed-6163714 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-61637142018-10-10 Design and Evaluation of a MEMS Magnetic Field Sensor-Based Respiratory Monitoring and Training System for Radiotherapy Oh, Yoonjin Jung, Young-Jin Choi, Sang Hyoun Kim, Dong Wook Sensors (Basel) Article The patient’s respiratory pattern and reproducibility are important factors affecting the accuracy of radiotherapy for lung cancer or liver cancer cases. Therefore, respiration training is required to induce respiration regularity before radiotherapy. However, the need for specialized personnel, space, and time-consuming training represent limitations. To solve these problems, we have developed a respiratory monitoring and training system based on a micro-electro-mechanical-system (MEMS) magnetic sensor. This system consists of a small attaching magnet, a sensor, and a breathing pattern output device. In this study, we evaluated the performance of the signal measurement in the developed system based on the various respiratory cycles, the amplitudes, and the position angles of the magnet and the sensor. The system can provide a more accurate breathing signal graph with lower measurement error and higher spatial resolution than conventional sensor methods by using additional magnet. In addition, it is possible the patient to monitor and train breathing himself by making it easy to carry and use without restriction of time and space. MDPI 2018-08-21 /pmc/articles/PMC6163714/ /pubmed/30134526 http://dx.doi.org/10.3390/s18092742 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Oh, Yoonjin Jung, Young-Jin Choi, Sang Hyoun Kim, Dong Wook Design and Evaluation of a MEMS Magnetic Field Sensor-Based Respiratory Monitoring and Training System for Radiotherapy |
title | Design and Evaluation of a MEMS Magnetic Field Sensor-Based Respiratory Monitoring and Training System for Radiotherapy |
title_full | Design and Evaluation of a MEMS Magnetic Field Sensor-Based Respiratory Monitoring and Training System for Radiotherapy |
title_fullStr | Design and Evaluation of a MEMS Magnetic Field Sensor-Based Respiratory Monitoring and Training System for Radiotherapy |
title_full_unstemmed | Design and Evaluation of a MEMS Magnetic Field Sensor-Based Respiratory Monitoring and Training System for Radiotherapy |
title_short | Design and Evaluation of a MEMS Magnetic Field Sensor-Based Respiratory Monitoring and Training System for Radiotherapy |
title_sort | design and evaluation of a mems magnetic field sensor-based respiratory monitoring and training system for radiotherapy |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6163714/ https://www.ncbi.nlm.nih.gov/pubmed/30134526 http://dx.doi.org/10.3390/s18092742 |
work_keys_str_mv | AT ohyoonjin designandevaluationofamemsmagneticfieldsensorbasedrespiratorymonitoringandtrainingsystemforradiotherapy AT jungyoungjin designandevaluationofamemsmagneticfieldsensorbasedrespiratorymonitoringandtrainingsystemforradiotherapy AT choisanghyoun designandevaluationofamemsmagneticfieldsensorbasedrespiratorymonitoringandtrainingsystemforradiotherapy AT kimdongwook designandevaluationofamemsmagneticfieldsensorbasedrespiratorymonitoringandtrainingsystemforradiotherapy |