Cargando…

Design and Evaluation of a MEMS Magnetic Field Sensor-Based Respiratory Monitoring and Training System for Radiotherapy

The patient’s respiratory pattern and reproducibility are important factors affecting the accuracy of radiotherapy for lung cancer or liver cancer cases. Therefore, respiration training is required to induce respiration regularity before radiotherapy. However, the need for specialized personnel, spa...

Descripción completa

Detalles Bibliográficos
Autores principales: Oh, Yoonjin, Jung, Young-Jin, Choi, Sang Hyoun, Kim, Dong Wook
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6163714/
https://www.ncbi.nlm.nih.gov/pubmed/30134526
http://dx.doi.org/10.3390/s18092742
_version_ 1783359427632431104
author Oh, Yoonjin
Jung, Young-Jin
Choi, Sang Hyoun
Kim, Dong Wook
author_facet Oh, Yoonjin
Jung, Young-Jin
Choi, Sang Hyoun
Kim, Dong Wook
author_sort Oh, Yoonjin
collection PubMed
description The patient’s respiratory pattern and reproducibility are important factors affecting the accuracy of radiotherapy for lung cancer or liver cancer cases. Therefore, respiration training is required to induce respiration regularity before radiotherapy. However, the need for specialized personnel, space, and time-consuming training represent limitations. To solve these problems, we have developed a respiratory monitoring and training system based on a micro-electro-mechanical-system (MEMS) magnetic sensor. This system consists of a small attaching magnet, a sensor, and a breathing pattern output device. In this study, we evaluated the performance of the signal measurement in the developed system based on the various respiratory cycles, the amplitudes, and the position angles of the magnet and the sensor. The system can provide a more accurate breathing signal graph with lower measurement error and higher spatial resolution than conventional sensor methods by using additional magnet. In addition, it is possible the patient to monitor and train breathing himself by making it easy to carry and use without restriction of time and space.
format Online
Article
Text
id pubmed-6163714
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-61637142018-10-10 Design and Evaluation of a MEMS Magnetic Field Sensor-Based Respiratory Monitoring and Training System for Radiotherapy Oh, Yoonjin Jung, Young-Jin Choi, Sang Hyoun Kim, Dong Wook Sensors (Basel) Article The patient’s respiratory pattern and reproducibility are important factors affecting the accuracy of radiotherapy for lung cancer or liver cancer cases. Therefore, respiration training is required to induce respiration regularity before radiotherapy. However, the need for specialized personnel, space, and time-consuming training represent limitations. To solve these problems, we have developed a respiratory monitoring and training system based on a micro-electro-mechanical-system (MEMS) magnetic sensor. This system consists of a small attaching magnet, a sensor, and a breathing pattern output device. In this study, we evaluated the performance of the signal measurement in the developed system based on the various respiratory cycles, the amplitudes, and the position angles of the magnet and the sensor. The system can provide a more accurate breathing signal graph with lower measurement error and higher spatial resolution than conventional sensor methods by using additional magnet. In addition, it is possible the patient to monitor and train breathing himself by making it easy to carry and use without restriction of time and space. MDPI 2018-08-21 /pmc/articles/PMC6163714/ /pubmed/30134526 http://dx.doi.org/10.3390/s18092742 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Oh, Yoonjin
Jung, Young-Jin
Choi, Sang Hyoun
Kim, Dong Wook
Design and Evaluation of a MEMS Magnetic Field Sensor-Based Respiratory Monitoring and Training System for Radiotherapy
title Design and Evaluation of a MEMS Magnetic Field Sensor-Based Respiratory Monitoring and Training System for Radiotherapy
title_full Design and Evaluation of a MEMS Magnetic Field Sensor-Based Respiratory Monitoring and Training System for Radiotherapy
title_fullStr Design and Evaluation of a MEMS Magnetic Field Sensor-Based Respiratory Monitoring and Training System for Radiotherapy
title_full_unstemmed Design and Evaluation of a MEMS Magnetic Field Sensor-Based Respiratory Monitoring and Training System for Radiotherapy
title_short Design and Evaluation of a MEMS Magnetic Field Sensor-Based Respiratory Monitoring and Training System for Radiotherapy
title_sort design and evaluation of a mems magnetic field sensor-based respiratory monitoring and training system for radiotherapy
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6163714/
https://www.ncbi.nlm.nih.gov/pubmed/30134526
http://dx.doi.org/10.3390/s18092742
work_keys_str_mv AT ohyoonjin designandevaluationofamemsmagneticfieldsensorbasedrespiratorymonitoringandtrainingsystemforradiotherapy
AT jungyoungjin designandevaluationofamemsmagneticfieldsensorbasedrespiratorymonitoringandtrainingsystemforradiotherapy
AT choisanghyoun designandevaluationofamemsmagneticfieldsensorbasedrespiratorymonitoringandtrainingsystemforradiotherapy
AT kimdongwook designandevaluationofamemsmagneticfieldsensorbasedrespiratorymonitoringandtrainingsystemforradiotherapy