Cargando…

Improvement of Left Ventricular Ejection Time Measurement in the Impedance Cardiography Combined with the Reflection Photoplethysmography

Cardiac stroke volume (SV) is an essential hemodynamic indicator that can be used to assess whether the pump function of the heart is normal. Non-invasive SV measurement is currently performed using the impedance cardiography (ICG). In this technology, left ventricular ejection time (LVET) is an imp...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Shing-Hong, Wang, Jia-Jung, Su, Chun-Hung, Cheng, Da-Chuan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6164077/
https://www.ncbi.nlm.nih.gov/pubmed/30208616
http://dx.doi.org/10.3390/s18093036
Descripción
Sumario:Cardiac stroke volume (SV) is an essential hemodynamic indicator that can be used to assess whether the pump function of the heart is normal. Non-invasive SV measurement is currently performed using the impedance cardiography (ICG). In this technology, left ventricular ejection time (LVET) is an important parameter which can be determined from the ICG signals. However, the ICG signals are inherently susceptible to artificial noise interference, which leads to an inaccurate LVET measurement and then yields an error in the calculation of SV. Therefore, the goal of the study was to measure LVETs using both the transmission and reflection photoplethysmography (PPG), and to assess whether the measured LVET was more accurate by the PPG signal than the ICG signal. The LVET measured by the phonocardiography (PCG) was used as the standard for comparing with those by the ICG and PPG. The study recruited ten subjects whose LVETs were simultaneously measured by the ICG using four electrodes, the reflection PPG using neck sensors (PPG(neck)) and the transmission PPG using finger sensors (PPG(finger)). In each subject, ten LVETs were obtained from ten heartbeats selected properly from one-minute recording. The differences of the measured LVETs between the PCG and one of the ICG, PPG(neck) and PPG(finger) were −68.2 ± 148.6 ms, 4.8 ± 86.5 ms and −7.0 ± 107.5 ms, respectively. As compared with the PCG, both the ICG and PPG(finger) underestimated but the PPG(neck) overestimated the LVETs. Furthermore, the measured LVET by the PPG(neck) was the closest to that by the PCG. Therefore, the PPG(neck) may be employed to improve the LVET measurement in applying the ICG for continuous monitoring of SV in clinical settings.