Cargando…

Field Evaluation of N95 Filtering Facepiece Respirators on Construction Jobsites for Protection against Airborne Ultrafine Particles

Exposure to high concentrations of airborne ultrafine particles in construction jobsites may play an important role in the adverse health effects among construction workers, therefore adequate respiratory protection is required. The performance of particulate respirators has never been evaluated in...

Descripción completa

Detalles Bibliográficos
Autores principales: Adhikari, Atin, Mitra, Aniruddha, Rashidi, Abbas, Ekpo, Imaobong, Schwartz, Jacob, Doehling, Jefferson
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6164087/
https://www.ncbi.nlm.nih.gov/pubmed/30205526
http://dx.doi.org/10.3390/ijerph15091958
_version_ 1783359516687990784
author Adhikari, Atin
Mitra, Aniruddha
Rashidi, Abbas
Ekpo, Imaobong
Schwartz, Jacob
Doehling, Jefferson
author_facet Adhikari, Atin
Mitra, Aniruddha
Rashidi, Abbas
Ekpo, Imaobong
Schwartz, Jacob
Doehling, Jefferson
author_sort Adhikari, Atin
collection PubMed
description Exposure to high concentrations of airborne ultrafine particles in construction jobsites may play an important role in the adverse health effects among construction workers, therefore adequate respiratory protection is required. The performance of particulate respirators has never been evaluated in field conditions against ultrafine particles on construction jobsites. In this study, respiratory protection levels against ultrafine particles of different size ranges were assessed during three common construction related jobs using a manikin-based set-up at 85 L/min air flow rate. Two NanoScan SMPS nanoparticle counters were utilized for measuring ultrafine particles in two sampling lines of the test filtering facepiece respirator—one from inside the respirator and one from outside the respirator. Particle size distributions were characterized using the NanoScan data collected from outside of the respirator. Two models of N95 respirators were tested—foldable and pleated. Collected data indicate that penetration of all categories of ultrafine particles can exceed 5% and smaller ultrafine particles of <36.5 nm size generally penetrated least. Foldable N95 filtering facepiece respirators were found to be less efficient than pleated N95 respirators in filtering nanoparticles mostly at the soil moving site and the wooden building frameworks construction site. Upon charge neutralization by isopropanol treatment, the ultrafine particles of larger sizes penetrated more compared to particles of smaller sizes. Our findings, therefore, indicate that N95 filtering facepiece respirators may not provide desirable 95% protection for most categories of ultrafine particles and generally, 95% protection is achievable for smaller particles of 11.5 to 20.5 nm sizes. We also conclude that foldable N95 respirators are less efficient than pleated N95 respirators in filtering ultrafine particles, mostly in the soil moving site and the wooden building framework construction site.
format Online
Article
Text
id pubmed-6164087
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-61640872018-10-12 Field Evaluation of N95 Filtering Facepiece Respirators on Construction Jobsites for Protection against Airborne Ultrafine Particles Adhikari, Atin Mitra, Aniruddha Rashidi, Abbas Ekpo, Imaobong Schwartz, Jacob Doehling, Jefferson Int J Environ Res Public Health Article Exposure to high concentrations of airborne ultrafine particles in construction jobsites may play an important role in the adverse health effects among construction workers, therefore adequate respiratory protection is required. The performance of particulate respirators has never been evaluated in field conditions against ultrafine particles on construction jobsites. In this study, respiratory protection levels against ultrafine particles of different size ranges were assessed during three common construction related jobs using a manikin-based set-up at 85 L/min air flow rate. Two NanoScan SMPS nanoparticle counters were utilized for measuring ultrafine particles in two sampling lines of the test filtering facepiece respirator—one from inside the respirator and one from outside the respirator. Particle size distributions were characterized using the NanoScan data collected from outside of the respirator. Two models of N95 respirators were tested—foldable and pleated. Collected data indicate that penetration of all categories of ultrafine particles can exceed 5% and smaller ultrafine particles of <36.5 nm size generally penetrated least. Foldable N95 filtering facepiece respirators were found to be less efficient than pleated N95 respirators in filtering nanoparticles mostly at the soil moving site and the wooden building frameworks construction site. Upon charge neutralization by isopropanol treatment, the ultrafine particles of larger sizes penetrated more compared to particles of smaller sizes. Our findings, therefore, indicate that N95 filtering facepiece respirators may not provide desirable 95% protection for most categories of ultrafine particles and generally, 95% protection is achievable for smaller particles of 11.5 to 20.5 nm sizes. We also conclude that foldable N95 respirators are less efficient than pleated N95 respirators in filtering ultrafine particles, mostly in the soil moving site and the wooden building framework construction site. MDPI 2018-09-07 2018-09 /pmc/articles/PMC6164087/ /pubmed/30205526 http://dx.doi.org/10.3390/ijerph15091958 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Adhikari, Atin
Mitra, Aniruddha
Rashidi, Abbas
Ekpo, Imaobong
Schwartz, Jacob
Doehling, Jefferson
Field Evaluation of N95 Filtering Facepiece Respirators on Construction Jobsites for Protection against Airborne Ultrafine Particles
title Field Evaluation of N95 Filtering Facepiece Respirators on Construction Jobsites for Protection against Airborne Ultrafine Particles
title_full Field Evaluation of N95 Filtering Facepiece Respirators on Construction Jobsites for Protection against Airborne Ultrafine Particles
title_fullStr Field Evaluation of N95 Filtering Facepiece Respirators on Construction Jobsites for Protection against Airborne Ultrafine Particles
title_full_unstemmed Field Evaluation of N95 Filtering Facepiece Respirators on Construction Jobsites for Protection against Airborne Ultrafine Particles
title_short Field Evaluation of N95 Filtering Facepiece Respirators on Construction Jobsites for Protection against Airborne Ultrafine Particles
title_sort field evaluation of n95 filtering facepiece respirators on construction jobsites for protection against airborne ultrafine particles
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6164087/
https://www.ncbi.nlm.nih.gov/pubmed/30205526
http://dx.doi.org/10.3390/ijerph15091958
work_keys_str_mv AT adhikariatin fieldevaluationofn95filteringfacepiecerespiratorsonconstructionjobsitesforprotectionagainstairborneultrafineparticles
AT mitraaniruddha fieldevaluationofn95filteringfacepiecerespiratorsonconstructionjobsitesforprotectionagainstairborneultrafineparticles
AT rashidiabbas fieldevaluationofn95filteringfacepiecerespiratorsonconstructionjobsitesforprotectionagainstairborneultrafineparticles
AT ekpoimaobong fieldevaluationofn95filteringfacepiecerespiratorsonconstructionjobsitesforprotectionagainstairborneultrafineparticles
AT schwartzjacob fieldevaluationofn95filteringfacepiecerespiratorsonconstructionjobsitesforprotectionagainstairborneultrafineparticles
AT doehlingjefferson fieldevaluationofn95filteringfacepiecerespiratorsonconstructionjobsitesforprotectionagainstairborneultrafineparticles