Cargando…
Evaluation of a Hydrogel-Based Diagnostic Approach for the Point-of-Care Based Detection of Neisseria gonorrhoeae
Eleven primer pairs were developed for the identification of Neisseria gonorrhoeae. The sensitivity and specificity of these primers were evaluated by Real Time (RT)-PCR melt curve analyses with DNA from 145 N. gonorrhoeae isolates and 40 other Neisseria or non-Neisseria species. Three primer pairs...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6164196/ https://www.ncbi.nlm.nih.gov/pubmed/30081551 http://dx.doi.org/10.3390/antibiotics7030070 |
_version_ | 1783359541456404480 |
---|---|
author | Perera, Sumudu R Taheri, Ali Khan, Nurul H Parti, Rajinder P Stefura, Stephanie Skiba, Pauline Acker, Jason P Martin, Irene Kusalik, Anthony Dillon, Jo-Anne R |
author_facet | Perera, Sumudu R Taheri, Ali Khan, Nurul H Parti, Rajinder P Stefura, Stephanie Skiba, Pauline Acker, Jason P Martin, Irene Kusalik, Anthony Dillon, Jo-Anne R |
author_sort | Perera, Sumudu R |
collection | PubMed |
description | Eleven primer pairs were developed for the identification of Neisseria gonorrhoeae. The sensitivity and specificity of these primers were evaluated by Real Time (RT)-PCR melt curve analyses with DNA from 145 N. gonorrhoeae isolates and 40 other Neisseria or non-Neisseria species. Three primer pairs were further evaluated in a hydrogel-based RT-PCR detection platform, using DNA extracted from 50 N. gonorrhoeae cultures. We observed 100% sensitivity and specificity in the hydrogel assay, confirming its potential as a point-of-care test (POCT) for N. gonorrhoeae diagnosis. |
format | Online Article Text |
id | pubmed-6164196 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-61641962018-10-12 Evaluation of a Hydrogel-Based Diagnostic Approach for the Point-of-Care Based Detection of Neisseria gonorrhoeae Perera, Sumudu R Taheri, Ali Khan, Nurul H Parti, Rajinder P Stefura, Stephanie Skiba, Pauline Acker, Jason P Martin, Irene Kusalik, Anthony Dillon, Jo-Anne R Antibiotics (Basel) Article Eleven primer pairs were developed for the identification of Neisseria gonorrhoeae. The sensitivity and specificity of these primers were evaluated by Real Time (RT)-PCR melt curve analyses with DNA from 145 N. gonorrhoeae isolates and 40 other Neisseria or non-Neisseria species. Three primer pairs were further evaluated in a hydrogel-based RT-PCR detection platform, using DNA extracted from 50 N. gonorrhoeae cultures. We observed 100% sensitivity and specificity in the hydrogel assay, confirming its potential as a point-of-care test (POCT) for N. gonorrhoeae diagnosis. MDPI 2018-08-04 /pmc/articles/PMC6164196/ /pubmed/30081551 http://dx.doi.org/10.3390/antibiotics7030070 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Perera, Sumudu R Taheri, Ali Khan, Nurul H Parti, Rajinder P Stefura, Stephanie Skiba, Pauline Acker, Jason P Martin, Irene Kusalik, Anthony Dillon, Jo-Anne R Evaluation of a Hydrogel-Based Diagnostic Approach for the Point-of-Care Based Detection of Neisseria gonorrhoeae |
title | Evaluation of a Hydrogel-Based Diagnostic Approach for the Point-of-Care Based Detection of Neisseria gonorrhoeae |
title_full | Evaluation of a Hydrogel-Based Diagnostic Approach for the Point-of-Care Based Detection of Neisseria gonorrhoeae |
title_fullStr | Evaluation of a Hydrogel-Based Diagnostic Approach for the Point-of-Care Based Detection of Neisseria gonorrhoeae |
title_full_unstemmed | Evaluation of a Hydrogel-Based Diagnostic Approach for the Point-of-Care Based Detection of Neisseria gonorrhoeae |
title_short | Evaluation of a Hydrogel-Based Diagnostic Approach for the Point-of-Care Based Detection of Neisseria gonorrhoeae |
title_sort | evaluation of a hydrogel-based diagnostic approach for the point-of-care based detection of neisseria gonorrhoeae |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6164196/ https://www.ncbi.nlm.nih.gov/pubmed/30081551 http://dx.doi.org/10.3390/antibiotics7030070 |
work_keys_str_mv | AT pererasumudur evaluationofahydrogelbaseddiagnosticapproachforthepointofcarebaseddetectionofneisseriagonorrhoeae AT taheriali evaluationofahydrogelbaseddiagnosticapproachforthepointofcarebaseddetectionofneisseriagonorrhoeae AT khannurulh evaluationofahydrogelbaseddiagnosticapproachforthepointofcarebaseddetectionofneisseriagonorrhoeae AT partirajinderp evaluationofahydrogelbaseddiagnosticapproachforthepointofcarebaseddetectionofneisseriagonorrhoeae AT stefurastephanie evaluationofahydrogelbaseddiagnosticapproachforthepointofcarebaseddetectionofneisseriagonorrhoeae AT skibapauline evaluationofahydrogelbaseddiagnosticapproachforthepointofcarebaseddetectionofneisseriagonorrhoeae AT ackerjasonp evaluationofahydrogelbaseddiagnosticapproachforthepointofcarebaseddetectionofneisseriagonorrhoeae AT martinirene evaluationofahydrogelbaseddiagnosticapproachforthepointofcarebaseddetectionofneisseriagonorrhoeae AT kusalikanthony evaluationofahydrogelbaseddiagnosticapproachforthepointofcarebaseddetectionofneisseriagonorrhoeae AT dillonjoanner evaluationofahydrogelbaseddiagnosticapproachforthepointofcarebaseddetectionofneisseriagonorrhoeae |