An Impedimetric Biosensor Based on Ionic Liquid-Modified Graphite Electrodes Developed for microRNA-34a Detection

In the present work, an impedimetric nucleic acid biosensor has been designed for the purpose of detection of microRNA (miRNA). Ionic liquid (1-butyl-3-methylimidazolium hexafluorophosphate (IL))-modified chemically activated pencil graphite electrodes (PGEs) were used for the sensitive and selectiv...

Descripción completa

Detalles Bibliográficos
Autores principales: Kesici, Ece, Eksin, Ece, Erdem, Arzum
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6164345/
https://www.ncbi.nlm.nih.gov/pubmed/30200274
http://dx.doi.org/10.3390/s18092868
_version_ 1783359577845137408
author Kesici, Ece
Eksin, Ece
Erdem, Arzum
author_facet Kesici, Ece
Eksin, Ece
Erdem, Arzum
author_sort Kesici, Ece
collection PubMed
description In the present work, an impedimetric nucleic acid biosensor has been designed for the purpose of detection of microRNA (miRNA). Ionic liquid (1-butyl-3-methylimidazolium hexafluorophosphate (IL))-modified chemically activated pencil graphite electrodes (PGEs) were used for the sensitive and selective detection of miRNA-34a. After covalent activation of the PGE surface using covalent agents (CAs), the ionic liquid (IL) was immobilized onto the surface of the chemically activated PGE by passive adsorption. The electrochemical and microscopic characterization of the IL/CA/PGEs was performed by electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and scanning electron microscopy (SEM). DNA probe concentration, miRNA target concentration, and also the hybridization time and wet adsorption time were optimized by using the EIS technique. Then, the hybridization occurred between specific DNA probes and miRNA-34a was immobilized onto the surface of the IL/CA/PGEs. The impedimetric detection of miRNA-DNA hybrid was performed by EIS. The detection limit (DL) was calculated in a linear concentration range of 2–10 µg/mL miRNA-34a target, and it was found to be 0.772 µg/mL (109 nM) in phosphate buffer solution (PBS) and 0.826 µg/mL (117 nM) in diluted fetal bovine serum (FBS). The selectivity of impedimetric biosensor for miRNA-34a was also tested against to other non-complementary miRNA sequences both in buffer media, or diluted FBS.
format Online
Article
Text
id pubmed-6164345
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-61643452018-10-10 An Impedimetric Biosensor Based on Ionic Liquid-Modified Graphite Electrodes Developed for microRNA-34a Detection Kesici, Ece Eksin, Ece Erdem, Arzum Sensors (Basel) Article In the present work, an impedimetric nucleic acid biosensor has been designed for the purpose of detection of microRNA (miRNA). Ionic liquid (1-butyl-3-methylimidazolium hexafluorophosphate (IL))-modified chemically activated pencil graphite electrodes (PGEs) were used for the sensitive and selective detection of miRNA-34a. After covalent activation of the PGE surface using covalent agents (CAs), the ionic liquid (IL) was immobilized onto the surface of the chemically activated PGE by passive adsorption. The electrochemical and microscopic characterization of the IL/CA/PGEs was performed by electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and scanning electron microscopy (SEM). DNA probe concentration, miRNA target concentration, and also the hybridization time and wet adsorption time were optimized by using the EIS technique. Then, the hybridization occurred between specific DNA probes and miRNA-34a was immobilized onto the surface of the IL/CA/PGEs. The impedimetric detection of miRNA-DNA hybrid was performed by EIS. The detection limit (DL) was calculated in a linear concentration range of 2–10 µg/mL miRNA-34a target, and it was found to be 0.772 µg/mL (109 nM) in phosphate buffer solution (PBS) and 0.826 µg/mL (117 nM) in diluted fetal bovine serum (FBS). The selectivity of impedimetric biosensor for miRNA-34a was also tested against to other non-complementary miRNA sequences both in buffer media, or diluted FBS. MDPI 2018-08-31 /pmc/articles/PMC6164345/ /pubmed/30200274 http://dx.doi.org/10.3390/s18092868 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Kesici, Ece
Eksin, Ece
Erdem, Arzum
An Impedimetric Biosensor Based on Ionic Liquid-Modified Graphite Electrodes Developed for microRNA-34a Detection
title An Impedimetric Biosensor Based on Ionic Liquid-Modified Graphite Electrodes Developed for microRNA-34a Detection
title_full An Impedimetric Biosensor Based on Ionic Liquid-Modified Graphite Electrodes Developed for microRNA-34a Detection
title_fullStr An Impedimetric Biosensor Based on Ionic Liquid-Modified Graphite Electrodes Developed for microRNA-34a Detection
title_full_unstemmed An Impedimetric Biosensor Based on Ionic Liquid-Modified Graphite Electrodes Developed for microRNA-34a Detection
title_short An Impedimetric Biosensor Based on Ionic Liquid-Modified Graphite Electrodes Developed for microRNA-34a Detection
title_sort impedimetric biosensor based on ionic liquid-modified graphite electrodes developed for microrna-34a detection
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6164345/
https://www.ncbi.nlm.nih.gov/pubmed/30200274
http://dx.doi.org/10.3390/s18092868
work_keys_str_mv AT kesiciece animpedimetricbiosensorbasedonionicliquidmodifiedgraphiteelectrodesdevelopedformicrorna34adetection
AT eksinece animpedimetricbiosensorbasedonionicliquidmodifiedgraphiteelectrodesdevelopedformicrorna34adetection
AT erdemarzum animpedimetricbiosensorbasedonionicliquidmodifiedgraphiteelectrodesdevelopedformicrorna34adetection
AT kesiciece impedimetricbiosensorbasedonionicliquidmodifiedgraphiteelectrodesdevelopedformicrorna34adetection
AT eksinece impedimetricbiosensorbasedonionicliquidmodifiedgraphiteelectrodesdevelopedformicrorna34adetection
AT erdemarzum impedimetricbiosensorbasedonionicliquidmodifiedgraphiteelectrodesdevelopedformicrorna34adetection