Cargando…
Precision and Accuracy of a Direct-Reading Miniaturized Monitor in PM(2.5) Exposure Assessment
The aim of this study was to evaluate the precision, accuracy, practicality, and potential uses of a PM(2.5) miniaturized monitor (MM) in exposure assessment. These monitors (AirBeam, HabitatMap) were compared with the widely used direct-reading particulate matter monitors and a gravimetric referenc...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6164905/ https://www.ncbi.nlm.nih.gov/pubmed/30217099 http://dx.doi.org/10.3390/s18093089 |
_version_ | 1783359711217713152 |
---|---|
author | Borghi, Francesca Spinazzè, Andrea Campagnolo, Davide Rovelli, Sabrina Cattaneo, Andrea Cavallo, Domenico M. |
author_facet | Borghi, Francesca Spinazzè, Andrea Campagnolo, Davide Rovelli, Sabrina Cattaneo, Andrea Cavallo, Domenico M. |
author_sort | Borghi, Francesca |
collection | PubMed |
description | The aim of this study was to evaluate the precision, accuracy, practicality, and potential uses of a PM(2.5) miniaturized monitor (MM) in exposure assessment. These monitors (AirBeam, HabitatMap) were compared with the widely used direct-reading particulate matter monitors and a gravimetric reference method for PM(2.5). Instruments were tested during 20 monitoring sessions that were subdivided in two different seasons to evaluate the performance of sensors across various environmental and meteorological conditions. Measurements were performed at an urban background site in Como, Italy. To evaluate the performance of the instruments, different analyses were conducted on 8-h averaged PM(2.5) concentrations for comparison between direct-reading monitors and the gravimetric method, and minute-averaged data for comparison between the direct-reading instruments. A linear regression analysis was performed to evaluate whether the two measurement methods, when compared, could be considered comparable and/or mutually predictive. Further, Bland-Altman plots were used to determine whether the methods were characterized by specific biases. Finally, the correlations between the error associated with the direct-reading instruments and the meteorological parameters acquired at the sampling point were investigated. Principal results show a moderate degree of agreement between MMs and the reference method and a bias that increased with an increase in PM(2.5) concentrations. |
format | Online Article Text |
id | pubmed-6164905 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-61649052018-10-10 Precision and Accuracy of a Direct-Reading Miniaturized Monitor in PM(2.5) Exposure Assessment Borghi, Francesca Spinazzè, Andrea Campagnolo, Davide Rovelli, Sabrina Cattaneo, Andrea Cavallo, Domenico M. Sensors (Basel) Article The aim of this study was to evaluate the precision, accuracy, practicality, and potential uses of a PM(2.5) miniaturized monitor (MM) in exposure assessment. These monitors (AirBeam, HabitatMap) were compared with the widely used direct-reading particulate matter monitors and a gravimetric reference method for PM(2.5). Instruments were tested during 20 monitoring sessions that were subdivided in two different seasons to evaluate the performance of sensors across various environmental and meteorological conditions. Measurements were performed at an urban background site in Como, Italy. To evaluate the performance of the instruments, different analyses were conducted on 8-h averaged PM(2.5) concentrations for comparison between direct-reading monitors and the gravimetric method, and minute-averaged data for comparison between the direct-reading instruments. A linear regression analysis was performed to evaluate whether the two measurement methods, when compared, could be considered comparable and/or mutually predictive. Further, Bland-Altman plots were used to determine whether the methods were characterized by specific biases. Finally, the correlations between the error associated with the direct-reading instruments and the meteorological parameters acquired at the sampling point were investigated. Principal results show a moderate degree of agreement between MMs and the reference method and a bias that increased with an increase in PM(2.5) concentrations. MDPI 2018-09-13 /pmc/articles/PMC6164905/ /pubmed/30217099 http://dx.doi.org/10.3390/s18093089 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Borghi, Francesca Spinazzè, Andrea Campagnolo, Davide Rovelli, Sabrina Cattaneo, Andrea Cavallo, Domenico M. Precision and Accuracy of a Direct-Reading Miniaturized Monitor in PM(2.5) Exposure Assessment |
title | Precision and Accuracy of a Direct-Reading Miniaturized Monitor in PM(2.5) Exposure Assessment |
title_full | Precision and Accuracy of a Direct-Reading Miniaturized Monitor in PM(2.5) Exposure Assessment |
title_fullStr | Precision and Accuracy of a Direct-Reading Miniaturized Monitor in PM(2.5) Exposure Assessment |
title_full_unstemmed | Precision and Accuracy of a Direct-Reading Miniaturized Monitor in PM(2.5) Exposure Assessment |
title_short | Precision and Accuracy of a Direct-Reading Miniaturized Monitor in PM(2.5) Exposure Assessment |
title_sort | precision and accuracy of a direct-reading miniaturized monitor in pm(2.5) exposure assessment |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6164905/ https://www.ncbi.nlm.nih.gov/pubmed/30217099 http://dx.doi.org/10.3390/s18093089 |
work_keys_str_mv | AT borghifrancesca precisionandaccuracyofadirectreadingminiaturizedmonitorinpm25exposureassessment AT spinazzeandrea precisionandaccuracyofadirectreadingminiaturizedmonitorinpm25exposureassessment AT campagnolodavide precisionandaccuracyofadirectreadingminiaturizedmonitorinpm25exposureassessment AT rovellisabrina precisionandaccuracyofadirectreadingminiaturizedmonitorinpm25exposureassessment AT cattaneoandrea precisionandaccuracyofadirectreadingminiaturizedmonitorinpm25exposureassessment AT cavallodomenicom precisionandaccuracyofadirectreadingminiaturizedmonitorinpm25exposureassessment |