Cargando…

Comparison of central corneal thickness measurements in corneal edema using ultrasound pachymetry, Visante anterior-segment optical coherence tomography, Cirrus optical coherence tomography, and Pentacam Scheimpflug camera tomography

PURPOSE: To compare the central corneal thickness (CCT) measurements in subjects with corneal edema using ultrasound pachymetry, Visante anterior-segment optical coherence tomography (OCT), Cirrus OCT, and Pentacam Scheimpflug camera tomography. METHODS: This prospective cross-sectional study includ...

Descripción completa

Detalles Bibliográficos
Autores principales: Wongchaisuwat, Nida, Metheetrairat, Ankana, Chonpimai, Pratuangsri, Nujoi, Waree, Prabhasawat, Pinnita
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6165728/
https://www.ncbi.nlm.nih.gov/pubmed/30310265
http://dx.doi.org/10.2147/OPTH.S172159
_version_ 1783359892993605632
author Wongchaisuwat, Nida
Metheetrairat, Ankana
Chonpimai, Pratuangsri
Nujoi, Waree
Prabhasawat, Pinnita
author_facet Wongchaisuwat, Nida
Metheetrairat, Ankana
Chonpimai, Pratuangsri
Nujoi, Waree
Prabhasawat, Pinnita
author_sort Wongchaisuwat, Nida
collection PubMed
description PURPOSE: To compare the central corneal thickness (CCT) measurements in subjects with corneal edema using ultrasound pachymetry, Visante anterior-segment optical coherence tomography (OCT), Cirrus OCT, and Pentacam Scheimpflug camera tomography. METHODS: This prospective cross-sectional study included 46 eyes of 33 patients with corneal edema and a CCT exceeding 550 μm evaluated by ultrasound pachymetry, Visante OCT, Cirrus OCT, and Pentacam. Two observers measured each eye twice. Intraobserver and interobserver reproducibility were determined and agreement among the devices calculated. RESULTS: CCT was measured in 40 eyes of 29 patients. Regardless of the CCT, the measurements obtained using Visante OCT, Cirrus CCT, and ultrasound pachymetry were well correlated. Interobserver and intraobserver reproducibility were high among the three devices. Pentacam overestimated the results compared with the other devices, and ultrasound pachymetry was unmeasurable in six (13%) eyes with very thick and opaque corneas. In eyes with mild corneal edema (CCT 551–650 μm), measurements from the four devices were comparable. CONCLUSION: All devices reliably measured the CCT <650 μm. In eyes with edema exceeding 650 μm, CCT measurements from the Visante OCT, Cirrus OCT, and ultrasound pachymetry devices showed good reproducibility and were well correlated, while the Pentacam overestimated the values compared to the other devices. Pentacam and ultrasound pachymetry should not be used in eyes with extreme corneal edema and opacity.
format Online
Article
Text
id pubmed-6165728
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-61657282018-10-11 Comparison of central corneal thickness measurements in corneal edema using ultrasound pachymetry, Visante anterior-segment optical coherence tomography, Cirrus optical coherence tomography, and Pentacam Scheimpflug camera tomography Wongchaisuwat, Nida Metheetrairat, Ankana Chonpimai, Pratuangsri Nujoi, Waree Prabhasawat, Pinnita Clin Ophthalmol Original Research PURPOSE: To compare the central corneal thickness (CCT) measurements in subjects with corneal edema using ultrasound pachymetry, Visante anterior-segment optical coherence tomography (OCT), Cirrus OCT, and Pentacam Scheimpflug camera tomography. METHODS: This prospective cross-sectional study included 46 eyes of 33 patients with corneal edema and a CCT exceeding 550 μm evaluated by ultrasound pachymetry, Visante OCT, Cirrus OCT, and Pentacam. Two observers measured each eye twice. Intraobserver and interobserver reproducibility were determined and agreement among the devices calculated. RESULTS: CCT was measured in 40 eyes of 29 patients. Regardless of the CCT, the measurements obtained using Visante OCT, Cirrus CCT, and ultrasound pachymetry were well correlated. Interobserver and intraobserver reproducibility were high among the three devices. Pentacam overestimated the results compared with the other devices, and ultrasound pachymetry was unmeasurable in six (13%) eyes with very thick and opaque corneas. In eyes with mild corneal edema (CCT 551–650 μm), measurements from the four devices were comparable. CONCLUSION: All devices reliably measured the CCT <650 μm. In eyes with edema exceeding 650 μm, CCT measurements from the Visante OCT, Cirrus OCT, and ultrasound pachymetry devices showed good reproducibility and were well correlated, while the Pentacam overestimated the values compared to the other devices. Pentacam and ultrasound pachymetry should not be used in eyes with extreme corneal edema and opacity. Dove Medical Press 2018-09-25 /pmc/articles/PMC6165728/ /pubmed/30310265 http://dx.doi.org/10.2147/OPTH.S172159 Text en © 2018 Wongchaisuwat et al. This work is published and licensed by Dove Medical Press Limited The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed.
spellingShingle Original Research
Wongchaisuwat, Nida
Metheetrairat, Ankana
Chonpimai, Pratuangsri
Nujoi, Waree
Prabhasawat, Pinnita
Comparison of central corneal thickness measurements in corneal edema using ultrasound pachymetry, Visante anterior-segment optical coherence tomography, Cirrus optical coherence tomography, and Pentacam Scheimpflug camera tomography
title Comparison of central corneal thickness measurements in corneal edema using ultrasound pachymetry, Visante anterior-segment optical coherence tomography, Cirrus optical coherence tomography, and Pentacam Scheimpflug camera tomography
title_full Comparison of central corneal thickness measurements in corneal edema using ultrasound pachymetry, Visante anterior-segment optical coherence tomography, Cirrus optical coherence tomography, and Pentacam Scheimpflug camera tomography
title_fullStr Comparison of central corneal thickness measurements in corneal edema using ultrasound pachymetry, Visante anterior-segment optical coherence tomography, Cirrus optical coherence tomography, and Pentacam Scheimpflug camera tomography
title_full_unstemmed Comparison of central corneal thickness measurements in corneal edema using ultrasound pachymetry, Visante anterior-segment optical coherence tomography, Cirrus optical coherence tomography, and Pentacam Scheimpflug camera tomography
title_short Comparison of central corneal thickness measurements in corneal edema using ultrasound pachymetry, Visante anterior-segment optical coherence tomography, Cirrus optical coherence tomography, and Pentacam Scheimpflug camera tomography
title_sort comparison of central corneal thickness measurements in corneal edema using ultrasound pachymetry, visante anterior-segment optical coherence tomography, cirrus optical coherence tomography, and pentacam scheimpflug camera tomography
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6165728/
https://www.ncbi.nlm.nih.gov/pubmed/30310265
http://dx.doi.org/10.2147/OPTH.S172159
work_keys_str_mv AT wongchaisuwatnida comparisonofcentralcornealthicknessmeasurementsincornealedemausingultrasoundpachymetryvisanteanteriorsegmentopticalcoherencetomographycirrusopticalcoherencetomographyandpentacamscheimpflugcameratomography
AT metheetrairatankana comparisonofcentralcornealthicknessmeasurementsincornealedemausingultrasoundpachymetryvisanteanteriorsegmentopticalcoherencetomographycirrusopticalcoherencetomographyandpentacamscheimpflugcameratomography
AT chonpimaipratuangsri comparisonofcentralcornealthicknessmeasurementsincornealedemausingultrasoundpachymetryvisanteanteriorsegmentopticalcoherencetomographycirrusopticalcoherencetomographyandpentacamscheimpflugcameratomography
AT nujoiwaree comparisonofcentralcornealthicknessmeasurementsincornealedemausingultrasoundpachymetryvisanteanteriorsegmentopticalcoherencetomographycirrusopticalcoherencetomographyandpentacamscheimpflugcameratomography
AT prabhasawatpinnita comparisonofcentralcornealthicknessmeasurementsincornealedemausingultrasoundpachymetryvisanteanteriorsegmentopticalcoherencetomographycirrusopticalcoherencetomographyandpentacamscheimpflugcameratomography