Cargando…
Evaluation of the efficacy of a medium cut-off dialyser and comparison with other high-flux dialysers in conventional haemodialysis and online haemodiafiltration
BACKGROUND: Online haemodiafiltration (OL-HDF) has been shown to reduce all-cause mortality versus conventional haemodialysis (HD); however, it is not always available. In these situations, a novel class of membranes with a higher pore size, medium cut-off (MCO) dialysers, could be promising. The ai...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6165747/ https://www.ncbi.nlm.nih.gov/pubmed/30288272 http://dx.doi.org/10.1093/ckj/sfy004 |
_version_ | 1783359897408110592 |
---|---|
author | García-Prieto, Ana Vega, Almudena Linares, Tania Abad, Soraya Macías, Nicolás Aragoncillo, Inés Torres, Esther Hernández, Andrés Barbieri, Diego Luño, José |
author_facet | García-Prieto, Ana Vega, Almudena Linares, Tania Abad, Soraya Macías, Nicolás Aragoncillo, Inés Torres, Esther Hernández, Andrés Barbieri, Diego Luño, José |
author_sort | García-Prieto, Ana |
collection | PubMed |
description | BACKGROUND: Online haemodiafiltration (OL-HDF) has been shown to reduce all-cause mortality versus conventional haemodialysis (HD); however, it is not always available. In these situations, a novel class of membranes with a higher pore size, medium cut-off (MCO) dialysers, could be promising. The aim of this study is to evaluate the efficacy of an MCO dialyser in the removal of small and medium-size molecules and compare it with standard high-flux (HF) dialysers in HD and OL-HDF. METHODS: In this crossover study, 18 prevalent HD patients were studied in three single mid-week dialysis treatments during three consecutive weeks as follows: first week with OL-HDF with a standard HF dialyser, second week with conventional HD with a standard HF dialyser and third week with conventional HD with an MCO dialyser. Reduction ratios (RRs) of different-sized molecules and albumin losses were collected for the different dialysers. RESULTS: MCO HD provided a greater reduction of middle and larger middle molecules compared with standard HF HD [rate reduction (RR) β2-microglobulin 74.7% versus 69.7%, P=0.01; RR myoglobin 62.5% versus 34.3%, P=0.001; RR prolactin 60% versus 32.8%, P=0.001; RR α1-glycoprotein 2.8% versus −0.1%, P=0.01]. We found no difference in the clearance of small and larger middle molecules comparing MCO HD with OL-HDF. Albumin losses were 0.03 g/session with MCO HD and 3.1 g/session with OL-HDF (P=0.001). CONCLUSION: MCO HD is superior to standard HF HD in the removal of middle and larger middle molecules and it is not inferior to OL-HDF in the clearance of small and larger middle molecules. Thus it could be an alternative in patients in which it is not possible to perform OL-HDF. |
format | Online Article Text |
id | pubmed-6165747 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-61657472018-10-04 Evaluation of the efficacy of a medium cut-off dialyser and comparison with other high-flux dialysers in conventional haemodialysis and online haemodiafiltration García-Prieto, Ana Vega, Almudena Linares, Tania Abad, Soraya Macías, Nicolás Aragoncillo, Inés Torres, Esther Hernández, Andrés Barbieri, Diego Luño, José Clin Kidney J Hemodialysis BACKGROUND: Online haemodiafiltration (OL-HDF) has been shown to reduce all-cause mortality versus conventional haemodialysis (HD); however, it is not always available. In these situations, a novel class of membranes with a higher pore size, medium cut-off (MCO) dialysers, could be promising. The aim of this study is to evaluate the efficacy of an MCO dialyser in the removal of small and medium-size molecules and compare it with standard high-flux (HF) dialysers in HD and OL-HDF. METHODS: In this crossover study, 18 prevalent HD patients were studied in three single mid-week dialysis treatments during three consecutive weeks as follows: first week with OL-HDF with a standard HF dialyser, second week with conventional HD with a standard HF dialyser and third week with conventional HD with an MCO dialyser. Reduction ratios (RRs) of different-sized molecules and albumin losses were collected for the different dialysers. RESULTS: MCO HD provided a greater reduction of middle and larger middle molecules compared with standard HF HD [rate reduction (RR) β2-microglobulin 74.7% versus 69.7%, P=0.01; RR myoglobin 62.5% versus 34.3%, P=0.001; RR prolactin 60% versus 32.8%, P=0.001; RR α1-glycoprotein 2.8% versus −0.1%, P=0.01]. We found no difference in the clearance of small and larger middle molecules comparing MCO HD with OL-HDF. Albumin losses were 0.03 g/session with MCO HD and 3.1 g/session with OL-HDF (P=0.001). CONCLUSION: MCO HD is superior to standard HF HD in the removal of middle and larger middle molecules and it is not inferior to OL-HDF in the clearance of small and larger middle molecules. Thus it could be an alternative in patients in which it is not possible to perform OL-HDF. Oxford University Press 2018-10 2018-02-26 /pmc/articles/PMC6165747/ /pubmed/30288272 http://dx.doi.org/10.1093/ckj/sfy004 Text en © The Author(s) 2018. Published by Oxford University Press on behalf of ERA-EDTA. http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com |
spellingShingle | Hemodialysis García-Prieto, Ana Vega, Almudena Linares, Tania Abad, Soraya Macías, Nicolás Aragoncillo, Inés Torres, Esther Hernández, Andrés Barbieri, Diego Luño, José Evaluation of the efficacy of a medium cut-off dialyser and comparison with other high-flux dialysers in conventional haemodialysis and online haemodiafiltration |
title | Evaluation of the efficacy of a medium cut-off dialyser and comparison with other high-flux dialysers in conventional haemodialysis and online haemodiafiltration |
title_full | Evaluation of the efficacy of a medium cut-off dialyser and comparison with other high-flux dialysers in conventional haemodialysis and online haemodiafiltration |
title_fullStr | Evaluation of the efficacy of a medium cut-off dialyser and comparison with other high-flux dialysers in conventional haemodialysis and online haemodiafiltration |
title_full_unstemmed | Evaluation of the efficacy of a medium cut-off dialyser and comparison with other high-flux dialysers in conventional haemodialysis and online haemodiafiltration |
title_short | Evaluation of the efficacy of a medium cut-off dialyser and comparison with other high-flux dialysers in conventional haemodialysis and online haemodiafiltration |
title_sort | evaluation of the efficacy of a medium cut-off dialyser and comparison with other high-flux dialysers in conventional haemodialysis and online haemodiafiltration |
topic | Hemodialysis |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6165747/ https://www.ncbi.nlm.nih.gov/pubmed/30288272 http://dx.doi.org/10.1093/ckj/sfy004 |
work_keys_str_mv | AT garciaprietoana evaluationoftheefficacyofamediumcutoffdialyserandcomparisonwithotherhighfluxdialysersinconventionalhaemodialysisandonlinehaemodiafiltration AT vegaalmudena evaluationoftheefficacyofamediumcutoffdialyserandcomparisonwithotherhighfluxdialysersinconventionalhaemodialysisandonlinehaemodiafiltration AT linarestania evaluationoftheefficacyofamediumcutoffdialyserandcomparisonwithotherhighfluxdialysersinconventionalhaemodialysisandonlinehaemodiafiltration AT abadsoraya evaluationoftheefficacyofamediumcutoffdialyserandcomparisonwithotherhighfluxdialysersinconventionalhaemodialysisandonlinehaemodiafiltration AT maciasnicolas evaluationoftheefficacyofamediumcutoffdialyserandcomparisonwithotherhighfluxdialysersinconventionalhaemodialysisandonlinehaemodiafiltration AT aragoncilloines evaluationoftheefficacyofamediumcutoffdialyserandcomparisonwithotherhighfluxdialysersinconventionalhaemodialysisandonlinehaemodiafiltration AT torresesther evaluationoftheefficacyofamediumcutoffdialyserandcomparisonwithotherhighfluxdialysersinconventionalhaemodialysisandonlinehaemodiafiltration AT hernandezandres evaluationoftheefficacyofamediumcutoffdialyserandcomparisonwithotherhighfluxdialysersinconventionalhaemodialysisandonlinehaemodiafiltration AT barbieridiego evaluationoftheefficacyofamediumcutoffdialyserandcomparisonwithotherhighfluxdialysersinconventionalhaemodialysisandonlinehaemodiafiltration AT lunojose evaluationoftheefficacyofamediumcutoffdialyserandcomparisonwithotherhighfluxdialysersinconventionalhaemodialysisandonlinehaemodiafiltration |