Cargando…

Early results for treatment of two- and three-part fractures of the proximal humerus using Contours PHP (proximal humeral plate)

Background and aim of the work: The management of displaced 2- and 3-part fractures of the proximal humerus is controversial, both in younger and in elderly patients. The purpose of this paper is to evaluate the functional results of the Contours Proximal Humerus Plate (Orthofix(R), Bussolengo,Veron...

Descripción completa

Detalles Bibliográficos
Autores principales: Biazzo, Alessio, Cardile, Carlo, Brunelli, Luca, Ragni, Paolo, Clementi, Daniele
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Mattioli 1885 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6166187/
https://www.ncbi.nlm.nih.gov/pubmed/28467336
http://dx.doi.org/10.23750/abm.v88i1.5193
_version_ 1783359990799532032
author Biazzo, Alessio
Cardile, Carlo
Brunelli, Luca
Ragni, Paolo
Clementi, Daniele
author_facet Biazzo, Alessio
Cardile, Carlo
Brunelli, Luca
Ragni, Paolo
Clementi, Daniele
author_sort Biazzo, Alessio
collection PubMed
description Background and aim of the work: The management of displaced 2- and 3-part fractures of the proximal humerus is controversial, both in younger and in elderly patients. The purpose of this paper is to evaluate the functional results of the Contours Proximal Humerus Plate (Orthofix(R), Bussolengo,Verona, Italy), for the treatment of displaced 2- and 3-part fractures of the proximal humerus. Methods: We retrospectively reviewed 55 patients with proximal humerus fractures, who underwent osteosynthesis with Contours Proximal Humerus Plate from December 2011 to March 2015. We had 21 patients with 2-part fractures and with an average age of 67.1 years and 34 patients with 3-part fractures, with average age of 63.6 years. Results: The average union time was 3 months. The mean Constant score was 67 for 2-part fracture group and 64.9 for 3-part fracture group. The difference was not statistically significant (p = 0.18). The overall complication rate was 14.5 %. Six patients underwent additional surgery (10.9%). Conclusions: The most frequent major complication was secondary loss of reduction following varus collapse of the fracture (2 cases). In these patients, there was loss of medial hinge integrity due to impaction and osteoporosis. The placement of the main locking screw in the calcar area to provide inferomedial support is the rational of the Contours Proximal Humerus Plate. Osteosynthesis with Contours Proximal Humerus Plate is a safe system for treating displaced 2- and 3-part fractures of the proximal humerus, with good functional results and complication rates comparable to those reported in the literature. (www.actabiomedica.it)
format Online
Article
Text
id pubmed-6166187
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Mattioli 1885
record_format MEDLINE/PubMed
spelling pubmed-61661872019-05-08 Early results for treatment of two- and three-part fractures of the proximal humerus using Contours PHP (proximal humeral plate) Biazzo, Alessio Cardile, Carlo Brunelli, Luca Ragni, Paolo Clementi, Daniele Acta Biomed Original Article Background and aim of the work: The management of displaced 2- and 3-part fractures of the proximal humerus is controversial, both in younger and in elderly patients. The purpose of this paper is to evaluate the functional results of the Contours Proximal Humerus Plate (Orthofix(R), Bussolengo,Verona, Italy), for the treatment of displaced 2- and 3-part fractures of the proximal humerus. Methods: We retrospectively reviewed 55 patients with proximal humerus fractures, who underwent osteosynthesis with Contours Proximal Humerus Plate from December 2011 to March 2015. We had 21 patients with 2-part fractures and with an average age of 67.1 years and 34 patients with 3-part fractures, with average age of 63.6 years. Results: The average union time was 3 months. The mean Constant score was 67 for 2-part fracture group and 64.9 for 3-part fracture group. The difference was not statistically significant (p = 0.18). The overall complication rate was 14.5 %. Six patients underwent additional surgery (10.9%). Conclusions: The most frequent major complication was secondary loss of reduction following varus collapse of the fracture (2 cases). In these patients, there was loss of medial hinge integrity due to impaction and osteoporosis. The placement of the main locking screw in the calcar area to provide inferomedial support is the rational of the Contours Proximal Humerus Plate. Osteosynthesis with Contours Proximal Humerus Plate is a safe system for treating displaced 2- and 3-part fractures of the proximal humerus, with good functional results and complication rates comparable to those reported in the literature. (www.actabiomedica.it) Mattioli 1885 2017 /pmc/articles/PMC6166187/ /pubmed/28467336 http://dx.doi.org/10.23750/abm.v88i1.5193 Text en Copyright: © 2017 ACTA BIO MEDICA SOCIETY OF MEDICINE AND NATURAL SCIENCES OF PARMA http://creativecommons.org/licenses/by-nc-sa/4.0 This work is licensed under a Creative Commons Attribution 4.0 International License
spellingShingle Original Article
Biazzo, Alessio
Cardile, Carlo
Brunelli, Luca
Ragni, Paolo
Clementi, Daniele
Early results for treatment of two- and three-part fractures of the proximal humerus using Contours PHP (proximal humeral plate)
title Early results for treatment of two- and three-part fractures of the proximal humerus using Contours PHP (proximal humeral plate)
title_full Early results for treatment of two- and three-part fractures of the proximal humerus using Contours PHP (proximal humeral plate)
title_fullStr Early results for treatment of two- and three-part fractures of the proximal humerus using Contours PHP (proximal humeral plate)
title_full_unstemmed Early results for treatment of two- and three-part fractures of the proximal humerus using Contours PHP (proximal humeral plate)
title_short Early results for treatment of two- and three-part fractures of the proximal humerus using Contours PHP (proximal humeral plate)
title_sort early results for treatment of two- and three-part fractures of the proximal humerus using contours php (proximal humeral plate)
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6166187/
https://www.ncbi.nlm.nih.gov/pubmed/28467336
http://dx.doi.org/10.23750/abm.v88i1.5193
work_keys_str_mv AT biazzoalessio earlyresultsfortreatmentoftwoandthreepartfracturesoftheproximalhumerususingcontoursphpproximalhumeralplate
AT cardilecarlo earlyresultsfortreatmentoftwoandthreepartfracturesoftheproximalhumerususingcontoursphpproximalhumeralplate
AT brunelliluca earlyresultsfortreatmentoftwoandthreepartfracturesoftheproximalhumerususingcontoursphpproximalhumeralplate
AT ragnipaolo earlyresultsfortreatmentoftwoandthreepartfracturesoftheproximalhumerususingcontoursphpproximalhumeralplate
AT clementidaniele earlyresultsfortreatmentoftwoandthreepartfracturesoftheproximalhumerususingcontoursphpproximalhumeralplate