Cargando…
Early results for treatment of two- and three-part fractures of the proximal humerus using Contours PHP (proximal humeral plate)
Background and aim of the work: The management of displaced 2- and 3-part fractures of the proximal humerus is controversial, both in younger and in elderly patients. The purpose of this paper is to evaluate the functional results of the Contours Proximal Humerus Plate (Orthofix(R), Bussolengo,Veron...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Mattioli 1885
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6166187/ https://www.ncbi.nlm.nih.gov/pubmed/28467336 http://dx.doi.org/10.23750/abm.v88i1.5193 |
_version_ | 1783359990799532032 |
---|---|
author | Biazzo, Alessio Cardile, Carlo Brunelli, Luca Ragni, Paolo Clementi, Daniele |
author_facet | Biazzo, Alessio Cardile, Carlo Brunelli, Luca Ragni, Paolo Clementi, Daniele |
author_sort | Biazzo, Alessio |
collection | PubMed |
description | Background and aim of the work: The management of displaced 2- and 3-part fractures of the proximal humerus is controversial, both in younger and in elderly patients. The purpose of this paper is to evaluate the functional results of the Contours Proximal Humerus Plate (Orthofix(R), Bussolengo,Verona, Italy), for the treatment of displaced 2- and 3-part fractures of the proximal humerus. Methods: We retrospectively reviewed 55 patients with proximal humerus fractures, who underwent osteosynthesis with Contours Proximal Humerus Plate from December 2011 to March 2015. We had 21 patients with 2-part fractures and with an average age of 67.1 years and 34 patients with 3-part fractures, with average age of 63.6 years. Results: The average union time was 3 months. The mean Constant score was 67 for 2-part fracture group and 64.9 for 3-part fracture group. The difference was not statistically significant (p = 0.18). The overall complication rate was 14.5 %. Six patients underwent additional surgery (10.9%). Conclusions: The most frequent major complication was secondary loss of reduction following varus collapse of the fracture (2 cases). In these patients, there was loss of medial hinge integrity due to impaction and osteoporosis. The placement of the main locking screw in the calcar area to provide inferomedial support is the rational of the Contours Proximal Humerus Plate. Osteosynthesis with Contours Proximal Humerus Plate is a safe system for treating displaced 2- and 3-part fractures of the proximal humerus, with good functional results and complication rates comparable to those reported in the literature. (www.actabiomedica.it) |
format | Online Article Text |
id | pubmed-6166187 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Mattioli 1885 |
record_format | MEDLINE/PubMed |
spelling | pubmed-61661872019-05-08 Early results for treatment of two- and three-part fractures of the proximal humerus using Contours PHP (proximal humeral plate) Biazzo, Alessio Cardile, Carlo Brunelli, Luca Ragni, Paolo Clementi, Daniele Acta Biomed Original Article Background and aim of the work: The management of displaced 2- and 3-part fractures of the proximal humerus is controversial, both in younger and in elderly patients. The purpose of this paper is to evaluate the functional results of the Contours Proximal Humerus Plate (Orthofix(R), Bussolengo,Verona, Italy), for the treatment of displaced 2- and 3-part fractures of the proximal humerus. Methods: We retrospectively reviewed 55 patients with proximal humerus fractures, who underwent osteosynthesis with Contours Proximal Humerus Plate from December 2011 to March 2015. We had 21 patients with 2-part fractures and with an average age of 67.1 years and 34 patients with 3-part fractures, with average age of 63.6 years. Results: The average union time was 3 months. The mean Constant score was 67 for 2-part fracture group and 64.9 for 3-part fracture group. The difference was not statistically significant (p = 0.18). The overall complication rate was 14.5 %. Six patients underwent additional surgery (10.9%). Conclusions: The most frequent major complication was secondary loss of reduction following varus collapse of the fracture (2 cases). In these patients, there was loss of medial hinge integrity due to impaction and osteoporosis. The placement of the main locking screw in the calcar area to provide inferomedial support is the rational of the Contours Proximal Humerus Plate. Osteosynthesis with Contours Proximal Humerus Plate is a safe system for treating displaced 2- and 3-part fractures of the proximal humerus, with good functional results and complication rates comparable to those reported in the literature. (www.actabiomedica.it) Mattioli 1885 2017 /pmc/articles/PMC6166187/ /pubmed/28467336 http://dx.doi.org/10.23750/abm.v88i1.5193 Text en Copyright: © 2017 ACTA BIO MEDICA SOCIETY OF MEDICINE AND NATURAL SCIENCES OF PARMA http://creativecommons.org/licenses/by-nc-sa/4.0 This work is licensed under a Creative Commons Attribution 4.0 International License |
spellingShingle | Original Article Biazzo, Alessio Cardile, Carlo Brunelli, Luca Ragni, Paolo Clementi, Daniele Early results for treatment of two- and three-part fractures of the proximal humerus using Contours PHP (proximal humeral plate) |
title | Early results for treatment of two- and three-part fractures of the proximal humerus using Contours PHP (proximal humeral plate) |
title_full | Early results for treatment of two- and three-part fractures of the proximal humerus using Contours PHP (proximal humeral plate) |
title_fullStr | Early results for treatment of two- and three-part fractures of the proximal humerus using Contours PHP (proximal humeral plate) |
title_full_unstemmed | Early results for treatment of two- and three-part fractures of the proximal humerus using Contours PHP (proximal humeral plate) |
title_short | Early results for treatment of two- and three-part fractures of the proximal humerus using Contours PHP (proximal humeral plate) |
title_sort | early results for treatment of two- and three-part fractures of the proximal humerus using contours php (proximal humeral plate) |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6166187/ https://www.ncbi.nlm.nih.gov/pubmed/28467336 http://dx.doi.org/10.23750/abm.v88i1.5193 |
work_keys_str_mv | AT biazzoalessio earlyresultsfortreatmentoftwoandthreepartfracturesoftheproximalhumerususingcontoursphpproximalhumeralplate AT cardilecarlo earlyresultsfortreatmentoftwoandthreepartfracturesoftheproximalhumerususingcontoursphpproximalhumeralplate AT brunelliluca earlyresultsfortreatmentoftwoandthreepartfracturesoftheproximalhumerususingcontoursphpproximalhumeralplate AT ragnipaolo earlyresultsfortreatmentoftwoandthreepartfracturesoftheproximalhumerususingcontoursphpproximalhumeralplate AT clementidaniele earlyresultsfortreatmentoftwoandthreepartfracturesoftheproximalhumerususingcontoursphpproximalhumeralplate |