Body Position Affects Ultrasonographic Measurement of Diaphragm Contractility
PURPOSE: (1) Determine whether ultrasonography can detect differences in diaphragm contractility between body positions. (2) Perform reliability analysis of diaphragm thickness measurements in each test condition. METHODS: We used a repeated-measures experimental design with 45 healthy adults where...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Lippincott Williams & Wilkins
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6166710/ https://www.ncbi.nlm.nih.gov/pubmed/30319315 http://dx.doi.org/10.1097/CPT.0000000000000083 |
Sumario: | PURPOSE: (1) Determine whether ultrasonography can detect differences in diaphragm contractility between body positions. (2) Perform reliability analysis of diaphragm thickness measurements in each test condition. METHODS: We used a repeated-measures experimental design with 45 healthy adults where 3 B-mode ultrasound images were collected at peak-inspiration and end-expiration in supine, sitting, and standing. Mean diaphragm thickening fractions were calculated for each test position. Statistical significance was tested using 1-way repeated-measures analysis of variance with planned comparisons. For reliability analysis, the intraclass correlation coefficient (3, 3) was calculated. RESULTS: Mean diaphragm thickening fraction increased from 60.2% (95% confidence interval [CI] 53.0%, 67.9%) in supine, to 96.5% (95% CI 83.2%, 109.9%) while seated and to 173.8% (95% CI 150.5%, 197.1%) while standing. Body position was a significant factor overall (P < .001), as were comparisons between each individual position (P < .001). Intraobserver reliability was excellent (>0.93) for all body positions tested. CONCLUSIONS: Ultrasound imaging detected positional differences in diaphragm contractility. The effect of gravitational loading on diaphragm length-tension, and body position-mediated changes in intra-abdominal pressure may explain the differences found. Future research should address methodological concerns and apply this method to patients participating in early mobilization programs in the intensive care unit. |
---|