Cargando…
Molecular pathological expression in malignant gliomas resected by fluorescein sodium-guiding under the YELLOW 560 nm surgical microscope filter
BACKGROUND: This study aimed to analyze the relationship between molecular pathologic expression of GFAP and Ki-67 and fluorescence levels, and to provide molecular pathological basis for the removal of malignant gliomas (MG) by Fluorescein Sodium (FLS) navigation under the YELLOW 560 nm surgical mi...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6167783/ https://www.ncbi.nlm.nih.gov/pubmed/30285781 http://dx.doi.org/10.1186/s12957-018-1495-2 |
_version_ | 1783360256919732224 |
---|---|
author | Zhang, Ningning Shang, Zhende Wang, Zhigang Meng, Xianbing Li, Zheng Tian, Hailong Huang, Dezhang Yin, Xin Zheng, Bin Zhang, Xinhua |
author_facet | Zhang, Ningning Shang, Zhende Wang, Zhigang Meng, Xianbing Li, Zheng Tian, Hailong Huang, Dezhang Yin, Xin Zheng, Bin Zhang, Xinhua |
author_sort | Zhang, Ningning |
collection | PubMed |
description | BACKGROUND: This study aimed to analyze the relationship between molecular pathologic expression of GFAP and Ki-67 and fluorescence levels, and to provide molecular pathological basis for the removal of malignant gliomas (MG) by Fluorescein Sodium (FLS) navigation under the YELLOW 560 nm surgical microscope filter. METHODS: A retrospective analysis of clinical data of 18 MG cases confirmed by the postoperative pathology was performed. All cases were resected by FLS guiding under the YELLOW 560 nm filter. Hematoxylin-eosin (HE) staining, molecular pathology markers GFAP, and Ki-67 immunohistochemical staining of the specimens were performed. The relationship between fluorescence staining levels and GFAP positive rate, Ki-67 proliferation index, and WHO grades was studied. RESULTS: There were 69 pathological specimens with fluorescence levels of “bright” fluorescence (n = 32), “low” fluorescence (n = 18), and “no” fluorescence (n = 19). Immunohistochemical staining showed GFAP-positive expression in both tumor cells and normal glial cells. The staining levels of the specimens in the fluorescence regions were higher than that in the non-fluorescence regions. GFAP expression was positive in 61 specimens and negative in 8 specimens. Comparison of Ki-67 proliferation index using chi-square test showed different fluorescence levels had different Ki-67 proliferation indexes (χ(2) = 14.678, p = 0.005). With high proliferation index of specimens, fluorescence level was brighter. WHO grade had no correlation with fluorescence levels (χ(2) = 3.531, p = 0.171). CONCLUSION: FLS-guided resection of MG is safe and effective. In the boundary area of MG, fluorescence levels and Ki-67 proliferation index showed correlation. FLS-guided resection achieved the function of “reducing tumor cell,” thus reducing the proliferation index in the lesion area. |
format | Online Article Text |
id | pubmed-6167783 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-61677832018-10-09 Molecular pathological expression in malignant gliomas resected by fluorescein sodium-guiding under the YELLOW 560 nm surgical microscope filter Zhang, Ningning Shang, Zhende Wang, Zhigang Meng, Xianbing Li, Zheng Tian, Hailong Huang, Dezhang Yin, Xin Zheng, Bin Zhang, Xinhua World J Surg Oncol Research BACKGROUND: This study aimed to analyze the relationship between molecular pathologic expression of GFAP and Ki-67 and fluorescence levels, and to provide molecular pathological basis for the removal of malignant gliomas (MG) by Fluorescein Sodium (FLS) navigation under the YELLOW 560 nm surgical microscope filter. METHODS: A retrospective analysis of clinical data of 18 MG cases confirmed by the postoperative pathology was performed. All cases were resected by FLS guiding under the YELLOW 560 nm filter. Hematoxylin-eosin (HE) staining, molecular pathology markers GFAP, and Ki-67 immunohistochemical staining of the specimens were performed. The relationship between fluorescence staining levels and GFAP positive rate, Ki-67 proliferation index, and WHO grades was studied. RESULTS: There were 69 pathological specimens with fluorescence levels of “bright” fluorescence (n = 32), “low” fluorescence (n = 18), and “no” fluorescence (n = 19). Immunohistochemical staining showed GFAP-positive expression in both tumor cells and normal glial cells. The staining levels of the specimens in the fluorescence regions were higher than that in the non-fluorescence regions. GFAP expression was positive in 61 specimens and negative in 8 specimens. Comparison of Ki-67 proliferation index using chi-square test showed different fluorescence levels had different Ki-67 proliferation indexes (χ(2) = 14.678, p = 0.005). With high proliferation index of specimens, fluorescence level was brighter. WHO grade had no correlation with fluorescence levels (χ(2) = 3.531, p = 0.171). CONCLUSION: FLS-guided resection of MG is safe and effective. In the boundary area of MG, fluorescence levels and Ki-67 proliferation index showed correlation. FLS-guided resection achieved the function of “reducing tumor cell,” thus reducing the proliferation index in the lesion area. BioMed Central 2018-10-01 /pmc/articles/PMC6167783/ /pubmed/30285781 http://dx.doi.org/10.1186/s12957-018-1495-2 Text en © The Author(s). 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Zhang, Ningning Shang, Zhende Wang, Zhigang Meng, Xianbing Li, Zheng Tian, Hailong Huang, Dezhang Yin, Xin Zheng, Bin Zhang, Xinhua Molecular pathological expression in malignant gliomas resected by fluorescein sodium-guiding under the YELLOW 560 nm surgical microscope filter |
title | Molecular pathological expression in malignant gliomas resected by fluorescein sodium-guiding under the YELLOW 560 nm surgical microscope filter |
title_full | Molecular pathological expression in malignant gliomas resected by fluorescein sodium-guiding under the YELLOW 560 nm surgical microscope filter |
title_fullStr | Molecular pathological expression in malignant gliomas resected by fluorescein sodium-guiding under the YELLOW 560 nm surgical microscope filter |
title_full_unstemmed | Molecular pathological expression in malignant gliomas resected by fluorescein sodium-guiding under the YELLOW 560 nm surgical microscope filter |
title_short | Molecular pathological expression in malignant gliomas resected by fluorescein sodium-guiding under the YELLOW 560 nm surgical microscope filter |
title_sort | molecular pathological expression in malignant gliomas resected by fluorescein sodium-guiding under the yellow 560 nm surgical microscope filter |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6167783/ https://www.ncbi.nlm.nih.gov/pubmed/30285781 http://dx.doi.org/10.1186/s12957-018-1495-2 |
work_keys_str_mv | AT zhangningning molecularpathologicalexpressioninmalignantgliomasresectedbyfluoresceinsodiumguidingundertheyellow560nmsurgicalmicroscopefilter AT shangzhende molecularpathologicalexpressioninmalignantgliomasresectedbyfluoresceinsodiumguidingundertheyellow560nmsurgicalmicroscopefilter AT wangzhigang molecularpathologicalexpressioninmalignantgliomasresectedbyfluoresceinsodiumguidingundertheyellow560nmsurgicalmicroscopefilter AT mengxianbing molecularpathologicalexpressioninmalignantgliomasresectedbyfluoresceinsodiumguidingundertheyellow560nmsurgicalmicroscopefilter AT lizheng molecularpathologicalexpressioninmalignantgliomasresectedbyfluoresceinsodiumguidingundertheyellow560nmsurgicalmicroscopefilter AT tianhailong molecularpathologicalexpressioninmalignantgliomasresectedbyfluoresceinsodiumguidingundertheyellow560nmsurgicalmicroscopefilter AT huangdezhang molecularpathologicalexpressioninmalignantgliomasresectedbyfluoresceinsodiumguidingundertheyellow560nmsurgicalmicroscopefilter AT yinxin molecularpathologicalexpressioninmalignantgliomasresectedbyfluoresceinsodiumguidingundertheyellow560nmsurgicalmicroscopefilter AT zhengbin molecularpathologicalexpressioninmalignantgliomasresectedbyfluoresceinsodiumguidingundertheyellow560nmsurgicalmicroscopefilter AT zhangxinhua molecularpathologicalexpressioninmalignantgliomasresectedbyfluoresceinsodiumguidingundertheyellow560nmsurgicalmicroscopefilter |