Trifecta St. Jude medical® aortic valve in pulmonary position

Introduction: To evaluate an aortic pericardial valve for pulmonary valve (PV) regurgitation after repair of congenital heart defects. Methods: From July 2012 to June 2016 71 patients, mean age 24 ± 13 years (four to years) underwent PV implantation of aortic pericardial valve, mean interval after p...

Descripción completa

Detalles Bibliográficos
Autores principales: Corno, Antonio F., Dawson, Alan G., Bolger, Aidan P., Mimic, Branco, Shebani, Suhair O., Skinner, Gregory J., Speggiorin, Simone
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Taylor & Francis 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6167870/
https://www.ncbi.nlm.nih.gov/pubmed/30410702
http://dx.doi.org/10.1080/20022727.2017.1299900
_version_ 1783360277501181952
author Corno, Antonio F.
Dawson, Alan G.
Bolger, Aidan P.
Mimic, Branco
Shebani, Suhair O.
Skinner, Gregory J.
Speggiorin, Simone
author_facet Corno, Antonio F.
Dawson, Alan G.
Bolger, Aidan P.
Mimic, Branco
Shebani, Suhair O.
Skinner, Gregory J.
Speggiorin, Simone
author_sort Corno, Antonio F.
collection PubMed
description Introduction: To evaluate an aortic pericardial valve for pulmonary valve (PV) regurgitation after repair of congenital heart defects. Methods: From July 2012 to June 2016 71 patients, mean age 24 ± 13 years (four to years) underwent PV implantation of aortic pericardial valve, mean interval after previous repair = 21 ± 10 years (two to 47 years). Previous surgery at mean age 3.2 ± 7.2 years (one day to 49 years): tetralogy of Fallot repair in 83% (59/71), pulmonary valvotomy in 11% (8/71), relief of right ventricular outflow tract (RVOT) obstruction in 6% (4/71). Pre-operative echocardiography and MRI showed severe PV regurgitation in 97% (69/71), moderate in 3% (2/71) with associated RVOT obstruction. MRI and knowledge-based reconstruction 3D volumetry (KBR-3D-volumetry) showed mean PV regurgitation = 42 ± 9% (20–58%), mean indexed RV end-diastolic volume = 169 ± 33 (130–265) ml m(–2) BSA and mean ejection fraction (EF) = 46 ± 8% (33–61%). Cardio-pulmonary exercise showed mean peak O(2)/uptake = 24 ± 8 ml kg(–1) min(–1) (14–45 ml kg(–1) min(–1)), predicted max O(2)/uptake 66 ± 17% (26–97%). Pre-operative NYHA class was I in 17% (12/71) patients, II in 70% (50/71) and III in 13% (9/71). Results: Mean cardio-pulmonary bypass duration was 95 ± 30ʹ (38–190ʹ), mean aortic cross-clamp in 23% (16/71) 46 ± 31ʹ (8–95ʹ), with 77% (55/71) implantations without aortic cross-clamp. Size of implanted PV: 21 mm in seven patients, 23 mm in 33, 25 mm in 23, and 27 mm in eight. The z-score of the implanted PV was −0.16 ± 0.80 (−1.6 to 2.5), effective orifice area indexed (for BSA) of native PV was 1.5 ± 0.2 (1.2 to –2.1) vs. implanted PV 1.2 ± 0.3 (0.76 to –2.5) (p = ns). In 76% (54/71) patients surgical RV modelling was associated. Mean duration of mechanical ventilation was 6 ± 5 h (0–26 h), mean ICU stay 21 ± 11 h (12–64 h), mean hospital stay 6 ± 3 days (three to 19 days). In mean follow-up = 25 ± 14 months (six to 53 months) there were no early/late deaths, no need for cardiac intervention/re-operation, no valve-related complications, thrombosis or endocarditis. Last echocardiography showed absent PV regurgitation in 87.3% (62/71) patients, trivial/mild degree in 11.3% (8/71), moderate degree in 1.45% (1/71), mean max peak velocity through RVOT 1.6 ± 0.4 (1.0–2.4) m s(–1). Mean indexed RV end-diastolic volume at MRI/KBR-3D-volumetry was 96 ± 20 (63–151) ml m(–2) BSA, lower than pre-operatively (p < 0.001), and mean EF = 55 ± 4% (49–61%), higher than pre-operatively (p < 0.05). Almost all patients (99% = 70/71) remain in NYHA class I, 1.45% = 1/71 in class II. Conclusion: (a) Aortic pericardial valve is implantable in PV position with an easy and reproducible surgical technique; (b) valve size adequate for patient BSA can be implanted with simultaneous RV remodelling; (c) medium-term outcomes are good with maintained PV function, RV dimensions significantly reduced and EF significantly improved; (d) adequate valve size will allow later percutaneous valve-in-valve implantation.
format Online
Article
Text
id pubmed-6167870
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Taylor & Francis
record_format MEDLINE/PubMed
spelling pubmed-61678702018-10-03 Trifecta St. Jude medical® aortic valve in pulmonary position Corno, Antonio F. Dawson, Alan G. Bolger, Aidan P. Mimic, Branco Shebani, Suhair O. Skinner, Gregory J. Speggiorin, Simone Nano Rev Exp Article Introduction: To evaluate an aortic pericardial valve for pulmonary valve (PV) regurgitation after repair of congenital heart defects. Methods: From July 2012 to June 2016 71 patients, mean age 24 ± 13 years (four to years) underwent PV implantation of aortic pericardial valve, mean interval after previous repair = 21 ± 10 years (two to 47 years). Previous surgery at mean age 3.2 ± 7.2 years (one day to 49 years): tetralogy of Fallot repair in 83% (59/71), pulmonary valvotomy in 11% (8/71), relief of right ventricular outflow tract (RVOT) obstruction in 6% (4/71). Pre-operative echocardiography and MRI showed severe PV regurgitation in 97% (69/71), moderate in 3% (2/71) with associated RVOT obstruction. MRI and knowledge-based reconstruction 3D volumetry (KBR-3D-volumetry) showed mean PV regurgitation = 42 ± 9% (20–58%), mean indexed RV end-diastolic volume = 169 ± 33 (130–265) ml m(–2) BSA and mean ejection fraction (EF) = 46 ± 8% (33–61%). Cardio-pulmonary exercise showed mean peak O(2)/uptake = 24 ± 8 ml kg(–1) min(–1) (14–45 ml kg(–1) min(–1)), predicted max O(2)/uptake 66 ± 17% (26–97%). Pre-operative NYHA class was I in 17% (12/71) patients, II in 70% (50/71) and III in 13% (9/71). Results: Mean cardio-pulmonary bypass duration was 95 ± 30ʹ (38–190ʹ), mean aortic cross-clamp in 23% (16/71) 46 ± 31ʹ (8–95ʹ), with 77% (55/71) implantations without aortic cross-clamp. Size of implanted PV: 21 mm in seven patients, 23 mm in 33, 25 mm in 23, and 27 mm in eight. The z-score of the implanted PV was −0.16 ± 0.80 (−1.6 to 2.5), effective orifice area indexed (for BSA) of native PV was 1.5 ± 0.2 (1.2 to –2.1) vs. implanted PV 1.2 ± 0.3 (0.76 to –2.5) (p = ns). In 76% (54/71) patients surgical RV modelling was associated. Mean duration of mechanical ventilation was 6 ± 5 h (0–26 h), mean ICU stay 21 ± 11 h (12–64 h), mean hospital stay 6 ± 3 days (three to 19 days). In mean follow-up = 25 ± 14 months (six to 53 months) there were no early/late deaths, no need for cardiac intervention/re-operation, no valve-related complications, thrombosis or endocarditis. Last echocardiography showed absent PV regurgitation in 87.3% (62/71) patients, trivial/mild degree in 11.3% (8/71), moderate degree in 1.45% (1/71), mean max peak velocity through RVOT 1.6 ± 0.4 (1.0–2.4) m s(–1). Mean indexed RV end-diastolic volume at MRI/KBR-3D-volumetry was 96 ± 20 (63–151) ml m(–2) BSA, lower than pre-operatively (p < 0.001), and mean EF = 55 ± 4% (49–61%), higher than pre-operatively (p < 0.05). Almost all patients (99% = 70/71) remain in NYHA class I, 1.45% = 1/71 in class II. Conclusion: (a) Aortic pericardial valve is implantable in PV position with an easy and reproducible surgical technique; (b) valve size adequate for patient BSA can be implanted with simultaneous RV remodelling; (c) medium-term outcomes are good with maintained PV function, RV dimensions significantly reduced and EF significantly improved; (d) adequate valve size will allow later percutaneous valve-in-valve implantation. Taylor & Francis 2017-05-01 /pmc/articles/PMC6167870/ /pubmed/30410702 http://dx.doi.org/10.1080/20022727.2017.1299900 Text en © 2017 The Author(s). Published by Informa UK Limited, trading as Taylor & Francis Group http://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Article
Corno, Antonio F.
Dawson, Alan G.
Bolger, Aidan P.
Mimic, Branco
Shebani, Suhair O.
Skinner, Gregory J.
Speggiorin, Simone
Trifecta St. Jude medical® aortic valve in pulmonary position
title Trifecta St. Jude medical® aortic valve in pulmonary position
title_full Trifecta St. Jude medical® aortic valve in pulmonary position
title_fullStr Trifecta St. Jude medical® aortic valve in pulmonary position
title_full_unstemmed Trifecta St. Jude medical® aortic valve in pulmonary position
title_short Trifecta St. Jude medical® aortic valve in pulmonary position
title_sort trifecta st. jude medical® aortic valve in pulmonary position
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6167870/
https://www.ncbi.nlm.nih.gov/pubmed/30410702
http://dx.doi.org/10.1080/20022727.2017.1299900
work_keys_str_mv AT cornoantoniof trifectastjudemedicalaorticvalveinpulmonaryposition
AT dawsonalang trifectastjudemedicalaorticvalveinpulmonaryposition
AT bolgeraidanp trifectastjudemedicalaorticvalveinpulmonaryposition
AT mimicbranco trifectastjudemedicalaorticvalveinpulmonaryposition
AT shebanisuhairo trifectastjudemedicalaorticvalveinpulmonaryposition
AT skinnergregoryj trifectastjudemedicalaorticvalveinpulmonaryposition
AT speggiorinsimone trifectastjudemedicalaorticvalveinpulmonaryposition