Cargando…

A Novel Antibacterial Membrane Electrode Based on Bacterial Cellulose/Polyaniline/AgNO(3) Composite for Bio-Potential Signal Monitoring

We propose a flexible, dry, and antibacterial electrode with a low and stable skin electrode contact impedance for bio-potential signal monitoring. We fabricated a bacterial cellulose/polyaniline/AgNO(3) nanocomposite membrane (BC/PANI/AgNO(3)) and used it for bio-potential signal monitoring. The ba...

Descripción completa

Detalles Bibliográficos
Formato: Online Artículo Texto
Lenguaje:English
Publicado: IEEE 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6168184/
https://www.ncbi.nlm.nih.gov/pubmed/30310760
http://dx.doi.org/10.1109/JTEHM.2018.2863388
Descripción
Sumario:We propose a flexible, dry, and antibacterial electrode with a low and stable skin electrode contact impedance for bio-potential signal monitoring. We fabricated a bacterial cellulose/polyaniline/AgNO(3) nanocomposite membrane (BC/PANI/AgNO(3)) and used it for bio-potential signal monitoring. The bacterial cellulose (BC) provides a 3-D nanoporous network structure, and it was used as a substrate material in the BC/PANI/AgNO(3) nanocomposite membrane. Polyaniline (PANI) and AgNO(3), acting as conductive and antibacterial components, respectively, were polymerized and deposited on the surfaces of BC nanofibers to produce uniform thin film membrane with flexible, antibacterial, and conductive properties. Various measurements were conducted, in terms of antibacterial activity, skin electrode contact impedance, and qualitative analysis of ECG signal recordings. The BC/PANI/AgNO3 membrane revealed 100% antibacterial activities against both the Staphylococcus aureus and Escherichia coli bacteria. The skin electrode contact impedance of the proposed BC/PANI/AgNO(3) electrode is lower than that of the Ag/AgCl gel electrode, with the same active area. In addition, the electrocardiogram (ECG) signals acquired with the proposed electrodes have stable characteristic waveforms, and they are not contaminated by noise. The waveform fidelity of the BC/PANI/AgNO(3) membrane electrodes over 800 ECG cardiac cycles is 99.49%, and after the electrodes were worn for 24 hours, a fidelity of 98.40% was recorded over the same number of cardiac cycles. With the low and stable skin electrode contact impedance, the proposed dry BC/PANI/AgNO(3) membrane electrode provided high fidelity for ECG signal recordings, thus offering a potential approach for bio-potential signal monitoring. With the above benefits, the novel flexible and dry BC/PANI/AgNO(3) electrode has a significant antibacterial. Most of all, it is the first research to develop antibacterial in the electrode design.