Cargando…

The difference of stress distribution of maxillary expansion using rapid maxillary expander (RME) and maxillary skeletal expander (MSE)—a finite element analysis

BACKGROUND: Maxillary skeletal expander (MSE) in combination with miniscrews was developed to overcome the drawbacks that may have resulted from the application of conventional rapid maxillary expander (RME). This research was conducted to analyze the difference of stress distribution of maxillary e...

Descripción completa

Detalles Bibliográficos
Autores principales: Hartono, Nathania, Soegiharto, Benny M., Widayati, Retno
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6168444/
https://www.ncbi.nlm.nih.gov/pubmed/30280257
http://dx.doi.org/10.1186/s40510-018-0229-x
_version_ 1783360348125921280
author Hartono, Nathania
Soegiharto, Benny M.
Widayati, Retno
author_facet Hartono, Nathania
Soegiharto, Benny M.
Widayati, Retno
author_sort Hartono, Nathania
collection PubMed
description BACKGROUND: Maxillary skeletal expander (MSE) in combination with miniscrews was developed to overcome the drawbacks that may have resulted from the application of conventional rapid maxillary expander (RME). This research was conducted to analyze the difference of stress distribution of maxillary expansion using RME and MSE in the region of interests (ROIs): first molars (M1), palatal alveolar bones of M1, palatine sutures, zygomatic sutures, miniscrews, and their surrounding bones. METHODS: A dry skull was scanned using CBCT and rendered into a three-dimensional (3D) model of craniomaxillary structures. The data analysis was done both visually and numerically. RESULT: The stress distributions in RME group were located at the palatal side of M1, mesial side of palatal alveolar of M1, pulp chamber of M1, and inferior cortex of palatine sutures. The stress distributions in the MSE group were located at the distopalatal cusp of M1, palatal side of palatal alveolar of M1, and inferior and superior cortex of palatine sutures. The stress distributions in zygomatic sutures on both groups were located at the zygomaticotemporal sutures, whereas in the miniscrews, the stress were located at the anterior miniscrews and palatal side of surrounding bones. CONCLUSIONS: There were significant differences of stress distribution of maxillary expansion measured in the ROIs in the craniomaxillary 3D model using RME and MSE.
format Online
Article
Text
id pubmed-6168444
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-61684442018-10-09 The difference of stress distribution of maxillary expansion using rapid maxillary expander (RME) and maxillary skeletal expander (MSE)—a finite element analysis Hartono, Nathania Soegiharto, Benny M. Widayati, Retno Prog Orthod Research BACKGROUND: Maxillary skeletal expander (MSE) in combination with miniscrews was developed to overcome the drawbacks that may have resulted from the application of conventional rapid maxillary expander (RME). This research was conducted to analyze the difference of stress distribution of maxillary expansion using RME and MSE in the region of interests (ROIs): first molars (M1), palatal alveolar bones of M1, palatine sutures, zygomatic sutures, miniscrews, and their surrounding bones. METHODS: A dry skull was scanned using CBCT and rendered into a three-dimensional (3D) model of craniomaxillary structures. The data analysis was done both visually and numerically. RESULT: The stress distributions in RME group were located at the palatal side of M1, mesial side of palatal alveolar of M1, pulp chamber of M1, and inferior cortex of palatine sutures. The stress distributions in the MSE group were located at the distopalatal cusp of M1, palatal side of palatal alveolar of M1, and inferior and superior cortex of palatine sutures. The stress distributions in zygomatic sutures on both groups were located at the zygomaticotemporal sutures, whereas in the miniscrews, the stress were located at the anterior miniscrews and palatal side of surrounding bones. CONCLUSIONS: There were significant differences of stress distribution of maxillary expansion measured in the ROIs in the craniomaxillary 3D model using RME and MSE. Springer Berlin Heidelberg 2018-10-03 /pmc/articles/PMC6168444/ /pubmed/30280257 http://dx.doi.org/10.1186/s40510-018-0229-x Text en © The Author(s). 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Research
Hartono, Nathania
Soegiharto, Benny M.
Widayati, Retno
The difference of stress distribution of maxillary expansion using rapid maxillary expander (RME) and maxillary skeletal expander (MSE)—a finite element analysis
title The difference of stress distribution of maxillary expansion using rapid maxillary expander (RME) and maxillary skeletal expander (MSE)—a finite element analysis
title_full The difference of stress distribution of maxillary expansion using rapid maxillary expander (RME) and maxillary skeletal expander (MSE)—a finite element analysis
title_fullStr The difference of stress distribution of maxillary expansion using rapid maxillary expander (RME) and maxillary skeletal expander (MSE)—a finite element analysis
title_full_unstemmed The difference of stress distribution of maxillary expansion using rapid maxillary expander (RME) and maxillary skeletal expander (MSE)—a finite element analysis
title_short The difference of stress distribution of maxillary expansion using rapid maxillary expander (RME) and maxillary skeletal expander (MSE)—a finite element analysis
title_sort difference of stress distribution of maxillary expansion using rapid maxillary expander (rme) and maxillary skeletal expander (mse)—a finite element analysis
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6168444/
https://www.ncbi.nlm.nih.gov/pubmed/30280257
http://dx.doi.org/10.1186/s40510-018-0229-x
work_keys_str_mv AT hartononathania thedifferenceofstressdistributionofmaxillaryexpansionusingrapidmaxillaryexpanderrmeandmaxillaryskeletalexpandermseafiniteelementanalysis
AT soegihartobennym thedifferenceofstressdistributionofmaxillaryexpansionusingrapidmaxillaryexpanderrmeandmaxillaryskeletalexpandermseafiniteelementanalysis
AT widayatiretno thedifferenceofstressdistributionofmaxillaryexpansionusingrapidmaxillaryexpanderrmeandmaxillaryskeletalexpandermseafiniteelementanalysis
AT hartononathania differenceofstressdistributionofmaxillaryexpansionusingrapidmaxillaryexpanderrmeandmaxillaryskeletalexpandermseafiniteelementanalysis
AT soegihartobennym differenceofstressdistributionofmaxillaryexpansionusingrapidmaxillaryexpanderrmeandmaxillaryskeletalexpandermseafiniteelementanalysis
AT widayatiretno differenceofstressdistributionofmaxillaryexpansionusingrapidmaxillaryexpanderrmeandmaxillaryskeletalexpandermseafiniteelementanalysis