Cargando…

Accuracy of different three-dimensional subcortical human brain atlases for DBS –lead localisation

BACKGROUND: Accurate interindividual comparability of deep brain stimulation (DBS) lead locations in relation to the surrounding anatomical structures is of eminent importance to define and understand effective stimulation areas. The objective of the current work is to compare the accuracy of the DB...

Descripción completa

Detalles Bibliográficos
Autores principales: Nowacki, Andreas, Nguyen, T.A-K., Tinkhauser, Gerd, Petermann, Katrin, Debove, Ines, Wiest, Roland, Pollo, Claudio
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6169097/
https://www.ncbi.nlm.nih.gov/pubmed/30282063
http://dx.doi.org/10.1016/j.nicl.2018.09.030
_version_ 1783360458657366016
author Nowacki, Andreas
Nguyen, T.A-K.
Tinkhauser, Gerd
Petermann, Katrin
Debove, Ines
Wiest, Roland
Pollo, Claudio
author_facet Nowacki, Andreas
Nguyen, T.A-K.
Tinkhauser, Gerd
Petermann, Katrin
Debove, Ines
Wiest, Roland
Pollo, Claudio
author_sort Nowacki, Andreas
collection PubMed
description BACKGROUND: Accurate interindividual comparability of deep brain stimulation (DBS) lead locations in relation to the surrounding anatomical structures is of eminent importance to define and understand effective stimulation areas. The objective of the current work is to compare the accuracy of the DBS lead localisation relative to the STN in native space with four recently developed three-dimensional subcortical brain atlases in the MNI template space. Accuracy is reviewed by anatomical and volumetric analysis as well as intraoperative electrophysiological data. METHODS: Postoperative lead localisations of 10 patients (19 hemispheres) were analysed in each individual patient based on Brainlab software (native space) and after normalization into the MNI space and application of 4 different human brain atlases using Lead-DBS toolbox within Matlab (template space). Each patient's STN was manually segmented and the relation between the reconstructed lead and the STN was compared to the 4 atlas-based STN models by applying the Dice coefficient. The length of intraoperative electrophysiological STN activity along different microelectrode recording tracks was measured and compared to reconstructions in native and template space. Descriptive non-parametric statistical tests were used to calculate differences between the 4 different atlases. RESULTS: The mean STN volume of the study cohort was 153.3 ± 40.3 mm3 (n = 19). This is similar to the STN volume of the DISTAL atlas (166 mm3; p = .22), but significantly larger compared to the other atlases tested in this study. The anatomical overlap of the lead-STN-reconstruction was highest for the DISTAL atlas (0.56 ± 0.18) and lowest for the PD25 atlas (0.34 ± 0.17). A total number of 47 MER trajectories through the STN were analysed. There was a statistically significant discrepancy of the electrophysiogical STN activity compared to the reconstructed STN of all four atlases (p < .0001). Conclusion: Lead reconstruction after normalization into the MNI template space and application of four different atlases led to different results in terms of the DBS lead position relative to the STN. Based on electrophysiological and imaging data, the DISTAL atlas led to the most accurate display of the reconstructed DBS lead relative to the DISTAL-based STN.
format Online
Article
Text
id pubmed-6169097
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-61690972018-10-05 Accuracy of different three-dimensional subcortical human brain atlases for DBS –lead localisation Nowacki, Andreas Nguyen, T.A-K. Tinkhauser, Gerd Petermann, Katrin Debove, Ines Wiest, Roland Pollo, Claudio Neuroimage Clin Regular Article BACKGROUND: Accurate interindividual comparability of deep brain stimulation (DBS) lead locations in relation to the surrounding anatomical structures is of eminent importance to define and understand effective stimulation areas. The objective of the current work is to compare the accuracy of the DBS lead localisation relative to the STN in native space with four recently developed three-dimensional subcortical brain atlases in the MNI template space. Accuracy is reviewed by anatomical and volumetric analysis as well as intraoperative electrophysiological data. METHODS: Postoperative lead localisations of 10 patients (19 hemispheres) were analysed in each individual patient based on Brainlab software (native space) and after normalization into the MNI space and application of 4 different human brain atlases using Lead-DBS toolbox within Matlab (template space). Each patient's STN was manually segmented and the relation between the reconstructed lead and the STN was compared to the 4 atlas-based STN models by applying the Dice coefficient. The length of intraoperative electrophysiological STN activity along different microelectrode recording tracks was measured and compared to reconstructions in native and template space. Descriptive non-parametric statistical tests were used to calculate differences between the 4 different atlases. RESULTS: The mean STN volume of the study cohort was 153.3 ± 40.3 mm3 (n = 19). This is similar to the STN volume of the DISTAL atlas (166 mm3; p = .22), but significantly larger compared to the other atlases tested in this study. The anatomical overlap of the lead-STN-reconstruction was highest for the DISTAL atlas (0.56 ± 0.18) and lowest for the PD25 atlas (0.34 ± 0.17). A total number of 47 MER trajectories through the STN were analysed. There was a statistically significant discrepancy of the electrophysiogical STN activity compared to the reconstructed STN of all four atlases (p < .0001). Conclusion: Lead reconstruction after normalization into the MNI template space and application of four different atlases led to different results in terms of the DBS lead position relative to the STN. Based on electrophysiological and imaging data, the DISTAL atlas led to the most accurate display of the reconstructed DBS lead relative to the DISTAL-based STN. Elsevier 2018-09-27 /pmc/articles/PMC6169097/ /pubmed/30282063 http://dx.doi.org/10.1016/j.nicl.2018.09.030 Text en © 2018 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Regular Article
Nowacki, Andreas
Nguyen, T.A-K.
Tinkhauser, Gerd
Petermann, Katrin
Debove, Ines
Wiest, Roland
Pollo, Claudio
Accuracy of different three-dimensional subcortical human brain atlases for DBS –lead localisation
title Accuracy of different three-dimensional subcortical human brain atlases for DBS –lead localisation
title_full Accuracy of different three-dimensional subcortical human brain atlases for DBS –lead localisation
title_fullStr Accuracy of different three-dimensional subcortical human brain atlases for DBS –lead localisation
title_full_unstemmed Accuracy of different three-dimensional subcortical human brain atlases for DBS –lead localisation
title_short Accuracy of different three-dimensional subcortical human brain atlases for DBS –lead localisation
title_sort accuracy of different three-dimensional subcortical human brain atlases for dbs –lead localisation
topic Regular Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6169097/
https://www.ncbi.nlm.nih.gov/pubmed/30282063
http://dx.doi.org/10.1016/j.nicl.2018.09.030
work_keys_str_mv AT nowackiandreas accuracyofdifferentthreedimensionalsubcorticalhumanbrainatlasesfordbsleadlocalisation
AT nguyentak accuracyofdifferentthreedimensionalsubcorticalhumanbrainatlasesfordbsleadlocalisation
AT tinkhausergerd accuracyofdifferentthreedimensionalsubcorticalhumanbrainatlasesfordbsleadlocalisation
AT petermannkatrin accuracyofdifferentthreedimensionalsubcorticalhumanbrainatlasesfordbsleadlocalisation
AT deboveines accuracyofdifferentthreedimensionalsubcorticalhumanbrainatlasesfordbsleadlocalisation
AT wiestroland accuracyofdifferentthreedimensionalsubcorticalhumanbrainatlasesfordbsleadlocalisation
AT polloclaudio accuracyofdifferentthreedimensionalsubcorticalhumanbrainatlasesfordbsleadlocalisation