Cargando…

Evaluation of AAA and XVMC Algorithms for Dose Calculation in Lung Equivalent Heterogeneity in Photon Fields: A Comparison of Calculated Results with Measurements

AIMS: The aims of the present work are (1) to evaluate dose calculation accuracy of two commonly used algorithms for 15 MV small photon fields in a medium encompassing heterogeneity and (2) to compare them with measured results obtained from gafchromic film EBT2. MATERIALS AND METHODS: Authors emplo...

Descripción completa

Detalles Bibliográficos
Autores principales: Singh, N., Painuly, N.K., Chaudhari, L.N., Chairmadurai, A., Verma, T., Shrotiya, D., Bhatt, C.P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Journal of Biomedical Physics and Engineering 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6169117/
https://www.ncbi.nlm.nih.gov/pubmed/30320026
_version_ 1783360462952333312
author Singh, N.
Painuly, N.K.
Chaudhari, L.N.
Chairmadurai, A.
Verma, T.
Shrotiya, D.
Bhatt, C.P.
author_facet Singh, N.
Painuly, N.K.
Chaudhari, L.N.
Chairmadurai, A.
Verma, T.
Shrotiya, D.
Bhatt, C.P.
author_sort Singh, N.
collection PubMed
description AIMS: The aims of the present work are (1) to evaluate dose calculation accuracy of two commonly used algorithms for 15 MV small photon fields in a medium encompassing heterogeneity and (2) to compare them with measured results obtained from gafchromic film EBT2. MATERIALS AND METHODS: Authors employed kailwood (Pinus Wallichiana) to mimic lung. Briefly, seven Kailwood plates, each measuring 25x25 cm(2) of varying thicknesses totaling 13 cm equivalent to the mean thickness of an adult human lung, were sandwiched between 5 cm tissue equivalent material from top and 10 cm below. Physical measurements were performed using Radiochromic film EBT2. The field sizes of 1x1, 2x2, 5x5 and 10x10 cm(2) were selected at 100 cm SSD. Simulations were performed using EGSnrc/DOSRZnrc Monte Carlo code. The dose variation inside the inhomogeneity and near the interface was calculated using AAA & XVMC algorithm. RESULTS: Preliminary results show that there is large variation of dose inside inhomogeneity. The maximum variation of dose inside the inhomogeneity for 1x1 cm(2) was found 40% by AAA and 4.5% by XVMC compared to measured/simulated results. For the field size of 2x2 cm(2), these figures were 27% by AAA & 3.5% by XVMC. For 5x5 cm(2) field size, the variation is small which becomes insignificant for larger fields. CONCLUSION: The results presented in this work indicate that for smaller fields, XVMC algorithm gives more realistic prediction, while there is the need for caution on using AAA algorithm for dose calculations involving small area irradiation encompassing heterogeneities and low-density media.
format Online
Article
Text
id pubmed-6169117
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Journal of Biomedical Physics and Engineering
record_format MEDLINE/PubMed
spelling pubmed-61691172018-10-12 Evaluation of AAA and XVMC Algorithms for Dose Calculation in Lung Equivalent Heterogeneity in Photon Fields: A Comparison of Calculated Results with Measurements Singh, N. Painuly, N.K. Chaudhari, L.N. Chairmadurai, A. Verma, T. Shrotiya, D. Bhatt, C.P. J Biomed Phys Eng Original Article AIMS: The aims of the present work are (1) to evaluate dose calculation accuracy of two commonly used algorithms for 15 MV small photon fields in a medium encompassing heterogeneity and (2) to compare them with measured results obtained from gafchromic film EBT2. MATERIALS AND METHODS: Authors employed kailwood (Pinus Wallichiana) to mimic lung. Briefly, seven Kailwood plates, each measuring 25x25 cm(2) of varying thicknesses totaling 13 cm equivalent to the mean thickness of an adult human lung, were sandwiched between 5 cm tissue equivalent material from top and 10 cm below. Physical measurements were performed using Radiochromic film EBT2. The field sizes of 1x1, 2x2, 5x5 and 10x10 cm(2) were selected at 100 cm SSD. Simulations were performed using EGSnrc/DOSRZnrc Monte Carlo code. The dose variation inside the inhomogeneity and near the interface was calculated using AAA & XVMC algorithm. RESULTS: Preliminary results show that there is large variation of dose inside inhomogeneity. The maximum variation of dose inside the inhomogeneity for 1x1 cm(2) was found 40% by AAA and 4.5% by XVMC compared to measured/simulated results. For the field size of 2x2 cm(2), these figures were 27% by AAA & 3.5% by XVMC. For 5x5 cm(2) field size, the variation is small which becomes insignificant for larger fields. CONCLUSION: The results presented in this work indicate that for smaller fields, XVMC algorithm gives more realistic prediction, while there is the need for caution on using AAA algorithm for dose calculations involving small area irradiation encompassing heterogeneities and low-density media. Journal of Biomedical Physics and Engineering 2018-09-01 /pmc/articles/PMC6169117/ /pubmed/30320026 Text en Copyright: © Journal of Biomedical Physics and Engineering http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Singh, N.
Painuly, N.K.
Chaudhari, L.N.
Chairmadurai, A.
Verma, T.
Shrotiya, D.
Bhatt, C.P.
Evaluation of AAA and XVMC Algorithms for Dose Calculation in Lung Equivalent Heterogeneity in Photon Fields: A Comparison of Calculated Results with Measurements
title Evaluation of AAA and XVMC Algorithms for Dose Calculation in Lung Equivalent Heterogeneity in Photon Fields: A Comparison of Calculated Results with Measurements
title_full Evaluation of AAA and XVMC Algorithms for Dose Calculation in Lung Equivalent Heterogeneity in Photon Fields: A Comparison of Calculated Results with Measurements
title_fullStr Evaluation of AAA and XVMC Algorithms for Dose Calculation in Lung Equivalent Heterogeneity in Photon Fields: A Comparison of Calculated Results with Measurements
title_full_unstemmed Evaluation of AAA and XVMC Algorithms for Dose Calculation in Lung Equivalent Heterogeneity in Photon Fields: A Comparison of Calculated Results with Measurements
title_short Evaluation of AAA and XVMC Algorithms for Dose Calculation in Lung Equivalent Heterogeneity in Photon Fields: A Comparison of Calculated Results with Measurements
title_sort evaluation of aaa and xvmc algorithms for dose calculation in lung equivalent heterogeneity in photon fields: a comparison of calculated results with measurements
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6169117/
https://www.ncbi.nlm.nih.gov/pubmed/30320026
work_keys_str_mv AT singhn evaluationofaaaandxvmcalgorithmsfordosecalculationinlungequivalentheterogeneityinphotonfieldsacomparisonofcalculatedresultswithmeasurements
AT painulynk evaluationofaaaandxvmcalgorithmsfordosecalculationinlungequivalentheterogeneityinphotonfieldsacomparisonofcalculatedresultswithmeasurements
AT chaudhariln evaluationofaaaandxvmcalgorithmsfordosecalculationinlungequivalentheterogeneityinphotonfieldsacomparisonofcalculatedresultswithmeasurements
AT chairmaduraia evaluationofaaaandxvmcalgorithmsfordosecalculationinlungequivalentheterogeneityinphotonfieldsacomparisonofcalculatedresultswithmeasurements
AT vermat evaluationofaaaandxvmcalgorithmsfordosecalculationinlungequivalentheterogeneityinphotonfieldsacomparisonofcalculatedresultswithmeasurements
AT shrotiyad evaluationofaaaandxvmcalgorithmsfordosecalculationinlungequivalentheterogeneityinphotonfieldsacomparisonofcalculatedresultswithmeasurements
AT bhattcp evaluationofaaaandxvmcalgorithmsfordosecalculationinlungequivalentheterogeneityinphotonfieldsacomparisonofcalculatedresultswithmeasurements