Cargando…
Two thermal performance test (TPT) datasets of a single U-tube borehole heat exchanger with inlet setpoint temperatures of 30 °C and 40 °C
The presented thermal performance test (TPT) datasets were related to the research article “New perspectives in thermal performance test: Cost-effective apparatus and extended data analysis” (Choi et al., 2018), where a new TPT apparatus was developed by adding a solid-state-relay and a proportional...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6169374/ https://www.ncbi.nlm.nih.gov/pubmed/30294622 http://dx.doi.org/10.1016/j.dib.2018.08.215 |
_version_ | 1783360505652445184 |
---|---|
author | Choi, Wonjun Kikumoto, Hideki Ooka, Ryozo |
author_facet | Choi, Wonjun Kikumoto, Hideki Ooka, Ryozo |
author_sort | Choi, Wonjun |
collection | PubMed |
description | The presented thermal performance test (TPT) datasets were related to the research article “New perspectives in thermal performance test: Cost-effective apparatus and extended data analysis” (Choi et al., 2018), where a new TPT apparatus was developed by adding a solid-state-relay and a proportional–integral–derivative (PID) controller to a thermal response test apparatus. Using the developed apparatus connected to a 50-m-long vertical ground heat exchanger, two TPTs were conducted for 144 h with inlet setpoint temperatures of 30 °C and 40 °C. The raw data were measured at 5 s intervals and consisted of the inlet, and outlet fluid temperatures, and the flow rate. The attached MATLAB script allows users to easily filter the data at user-specified time intervals. Moreover, the execution of code provides two additional quantities: heat injection rate and unit heat exchange rate. The datasets are shared for the following purposes: (1) performance comparison of various ground heat exchangers using the unit heat exchange rate (2) comparison of the control performance of a newly developed TPT apparatus, (3) validation of an analytical or numerical thermal response model, and (4) validation of a parameter estimation algorithm. |
format | Online Article Text |
id | pubmed-6169374 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-61693742018-10-05 Two thermal performance test (TPT) datasets of a single U-tube borehole heat exchanger with inlet setpoint temperatures of 30 °C and 40 °C Choi, Wonjun Kikumoto, Hideki Ooka, Ryozo Data Brief Engineering The presented thermal performance test (TPT) datasets were related to the research article “New perspectives in thermal performance test: Cost-effective apparatus and extended data analysis” (Choi et al., 2018), where a new TPT apparatus was developed by adding a solid-state-relay and a proportional–integral–derivative (PID) controller to a thermal response test apparatus. Using the developed apparatus connected to a 50-m-long vertical ground heat exchanger, two TPTs were conducted for 144 h with inlet setpoint temperatures of 30 °C and 40 °C. The raw data were measured at 5 s intervals and consisted of the inlet, and outlet fluid temperatures, and the flow rate. The attached MATLAB script allows users to easily filter the data at user-specified time intervals. Moreover, the execution of code provides two additional quantities: heat injection rate and unit heat exchange rate. The datasets are shared for the following purposes: (1) performance comparison of various ground heat exchangers using the unit heat exchange rate (2) comparison of the control performance of a newly developed TPT apparatus, (3) validation of an analytical or numerical thermal response model, and (4) validation of a parameter estimation algorithm. Elsevier 2018-09-08 /pmc/articles/PMC6169374/ /pubmed/30294622 http://dx.doi.org/10.1016/j.dib.2018.08.215 Text en © 2018 Published by Elsevier Inc. http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Engineering Choi, Wonjun Kikumoto, Hideki Ooka, Ryozo Two thermal performance test (TPT) datasets of a single U-tube borehole heat exchanger with inlet setpoint temperatures of 30 °C and 40 °C |
title | Two thermal performance test (TPT) datasets of a single U-tube borehole heat exchanger with inlet setpoint temperatures of 30 °C and 40 °C |
title_full | Two thermal performance test (TPT) datasets of a single U-tube borehole heat exchanger with inlet setpoint temperatures of 30 °C and 40 °C |
title_fullStr | Two thermal performance test (TPT) datasets of a single U-tube borehole heat exchanger with inlet setpoint temperatures of 30 °C and 40 °C |
title_full_unstemmed | Two thermal performance test (TPT) datasets of a single U-tube borehole heat exchanger with inlet setpoint temperatures of 30 °C and 40 °C |
title_short | Two thermal performance test (TPT) datasets of a single U-tube borehole heat exchanger with inlet setpoint temperatures of 30 °C and 40 °C |
title_sort | two thermal performance test (tpt) datasets of a single u-tube borehole heat exchanger with inlet setpoint temperatures of 30 °c and 40 °c |
topic | Engineering |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6169374/ https://www.ncbi.nlm.nih.gov/pubmed/30294622 http://dx.doi.org/10.1016/j.dib.2018.08.215 |
work_keys_str_mv | AT choiwonjun twothermalperformancetesttptdatasetsofasingleutubeboreholeheatexchangerwithinletsetpointtemperaturesof30cand40c AT kikumotohideki twothermalperformancetesttptdatasetsofasingleutubeboreholeheatexchangerwithinletsetpointtemperaturesof30cand40c AT ookaryozo twothermalperformancetesttptdatasetsofasingleutubeboreholeheatexchangerwithinletsetpointtemperaturesof30cand40c |