Two thermal performance test (TPT) datasets of a single U-tube borehole heat exchanger with inlet setpoint temperatures of 30 °C and 40 °C

The presented thermal performance test (TPT) datasets were related to the research article “New perspectives in thermal performance test: Cost-effective apparatus and extended data analysis” (Choi et al., 2018), where a new TPT apparatus was developed by adding a solid-state-relay and a proportional...

Descripción completa

Detalles Bibliográficos
Autores principales: Choi, Wonjun, Kikumoto, Hideki, Ooka, Ryozo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6169374/
https://www.ncbi.nlm.nih.gov/pubmed/30294622
http://dx.doi.org/10.1016/j.dib.2018.08.215
_version_ 1783360505652445184
author Choi, Wonjun
Kikumoto, Hideki
Ooka, Ryozo
author_facet Choi, Wonjun
Kikumoto, Hideki
Ooka, Ryozo
author_sort Choi, Wonjun
collection PubMed
description The presented thermal performance test (TPT) datasets were related to the research article “New perspectives in thermal performance test: Cost-effective apparatus and extended data analysis” (Choi et al., 2018), where a new TPT apparatus was developed by adding a solid-state-relay and a proportional–integral–derivative (PID) controller to a thermal response test apparatus. Using the developed apparatus connected to a 50-m-long vertical ground heat exchanger, two TPTs were conducted for 144 h with inlet setpoint temperatures of 30 °C and 40 °C. The raw data were measured at 5 s intervals and consisted of the inlet, and outlet fluid temperatures, and the flow rate. The attached MATLAB script allows users to easily filter the data at user-specified time intervals. Moreover, the execution of code provides two additional quantities: heat injection rate and unit heat exchange rate. The datasets are shared for the following purposes: (1) performance comparison of various ground heat exchangers using the unit heat exchange rate (2) comparison of the control performance of a newly developed TPT apparatus, (3) validation of an analytical or numerical thermal response model, and (4) validation of a parameter estimation algorithm.
format Online
Article
Text
id pubmed-6169374
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-61693742018-10-05 Two thermal performance test (TPT) datasets of a single U-tube borehole heat exchanger with inlet setpoint temperatures of 30 °C and 40 °C Choi, Wonjun Kikumoto, Hideki Ooka, Ryozo Data Brief Engineering The presented thermal performance test (TPT) datasets were related to the research article “New perspectives in thermal performance test: Cost-effective apparatus and extended data analysis” (Choi et al., 2018), where a new TPT apparatus was developed by adding a solid-state-relay and a proportional–integral–derivative (PID) controller to a thermal response test apparatus. Using the developed apparatus connected to a 50-m-long vertical ground heat exchanger, two TPTs were conducted for 144 h with inlet setpoint temperatures of 30 °C and 40 °C. The raw data were measured at 5 s intervals and consisted of the inlet, and outlet fluid temperatures, and the flow rate. The attached MATLAB script allows users to easily filter the data at user-specified time intervals. Moreover, the execution of code provides two additional quantities: heat injection rate and unit heat exchange rate. The datasets are shared for the following purposes: (1) performance comparison of various ground heat exchangers using the unit heat exchange rate (2) comparison of the control performance of a newly developed TPT apparatus, (3) validation of an analytical or numerical thermal response model, and (4) validation of a parameter estimation algorithm. Elsevier 2018-09-08 /pmc/articles/PMC6169374/ /pubmed/30294622 http://dx.doi.org/10.1016/j.dib.2018.08.215 Text en © 2018 Published by Elsevier Inc. http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Engineering
Choi, Wonjun
Kikumoto, Hideki
Ooka, Ryozo
Two thermal performance test (TPT) datasets of a single U-tube borehole heat exchanger with inlet setpoint temperatures of 30 °C and 40 °C
title Two thermal performance test (TPT) datasets of a single U-tube borehole heat exchanger with inlet setpoint temperatures of 30 °C and 40 °C
title_full Two thermal performance test (TPT) datasets of a single U-tube borehole heat exchanger with inlet setpoint temperatures of 30 °C and 40 °C
title_fullStr Two thermal performance test (TPT) datasets of a single U-tube borehole heat exchanger with inlet setpoint temperatures of 30 °C and 40 °C
title_full_unstemmed Two thermal performance test (TPT) datasets of a single U-tube borehole heat exchanger with inlet setpoint temperatures of 30 °C and 40 °C
title_short Two thermal performance test (TPT) datasets of a single U-tube borehole heat exchanger with inlet setpoint temperatures of 30 °C and 40 °C
title_sort two thermal performance test (tpt) datasets of a single u-tube borehole heat exchanger with inlet setpoint temperatures of 30 °c and 40 °c
topic Engineering
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6169374/
https://www.ncbi.nlm.nih.gov/pubmed/30294622
http://dx.doi.org/10.1016/j.dib.2018.08.215
work_keys_str_mv AT choiwonjun twothermalperformancetesttptdatasetsofasingleutubeboreholeheatexchangerwithinletsetpointtemperaturesof30cand40c
AT kikumotohideki twothermalperformancetesttptdatasetsofasingleutubeboreholeheatexchangerwithinletsetpointtemperaturesof30cand40c
AT ookaryozo twothermalperformancetesttptdatasetsofasingleutubeboreholeheatexchangerwithinletsetpointtemperaturesof30cand40c