Evaluation of the quality of cardiopulmonary resuscitation according to vehicle driving pattern, using a virtual reality ambulance driving system: a prospective, cross-over, randomised study

OBJECTIVES: To analyse changes in the quality of cardiopulmonary resuscitation (CPR) according to driving patterns encountered during ambulance transport, using a virtual reality simulator. DESIGN: Prospective, cross-over, randomised study. SETTING: This study was conducted at the National Fire Serv...

Descripción completa

Detalles Bibliográficos
Autores principales: Beom, Jin Ho, Kim, Min Joung, You, Je Sung, Lee, Hye Sun, Kim, Ji Hoon, Park, Yoo Seok, Shin, Dong Min, Chung, Hyun Soo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Publishing Group 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6169751/
https://www.ncbi.nlm.nih.gov/pubmed/30269076
http://dx.doi.org/10.1136/bmjopen-2018-023784
_version_ 1783360554308468736
author Beom, Jin Ho
Kim, Min Joung
You, Je Sung
Lee, Hye Sun
Kim, Ji Hoon
Park, Yoo Seok
Shin, Dong Min
Chung, Hyun Soo
author_facet Beom, Jin Ho
Kim, Min Joung
You, Je Sung
Lee, Hye Sun
Kim, Ji Hoon
Park, Yoo Seok
Shin, Dong Min
Chung, Hyun Soo
author_sort Beom, Jin Ho
collection PubMed
description OBJECTIVES: To analyse changes in the quality of cardiopulmonary resuscitation (CPR) according to driving patterns encountered during ambulance transport, using a virtual reality simulator. DESIGN: Prospective, cross-over, randomised study. SETTING: This study was conducted at the National Fire Service Academy, Cheonan-si, Korea. PARTICIPANTS: Emergency medical technicians (39 men and 9 women) attending the National Fire Service Academy for clinical training with ≥6 months field experience or having performed ≥10 CPR. Individuals who withdrew consent were excluded. OUTCOME MEASURES: CPR quality parameters (eg, chest compression depth and its variability). RESULTS: Chest compressions were performed for 8 min each in a stationary and driving state. The mean chest compression depths were 54.8 mm and 55.3 mm during these two states, respectively (p=0.41). The SD of the chest compression depth was significantly higher while in the driving (7.6 mm) than in the stationary state (6.5 mm; p=0.04). The compression depths in the speed bump and sudden stop sections were 51.5 mm and 50.6 mm, respectively, which was shallower than those in all other sections (p<0.001). The correct hand position rate was low in the speed bump, sudden stop and right-hand cornering sections (65.4%, 71.5% and 72.5%, respectively; p=0.001) CONCLUSIONS: Although we found no differences in chest compression quality parameters between the stationary and driving states, the variability in the chest compression depth increased in the driving state. When comparing CPR quality parameters according to driving patterns, we noted a shallower compression depth, increased variability and decreased correct hand position rate in the speed bump, sudden stop and right-hand cornering sections. The clinical significance of these changes in CPR quality during ambulance transport remains to be determined. Future studies on how to reduce changes in the quality of CPR (including research on equipment development) are needed.
format Online
Article
Text
id pubmed-6169751
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher BMJ Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-61697512018-10-05 Evaluation of the quality of cardiopulmonary resuscitation according to vehicle driving pattern, using a virtual reality ambulance driving system: a prospective, cross-over, randomised study Beom, Jin Ho Kim, Min Joung You, Je Sung Lee, Hye Sun Kim, Ji Hoon Park, Yoo Seok Shin, Dong Min Chung, Hyun Soo BMJ Open Cardiovascular Medicine OBJECTIVES: To analyse changes in the quality of cardiopulmonary resuscitation (CPR) according to driving patterns encountered during ambulance transport, using a virtual reality simulator. DESIGN: Prospective, cross-over, randomised study. SETTING: This study was conducted at the National Fire Service Academy, Cheonan-si, Korea. PARTICIPANTS: Emergency medical technicians (39 men and 9 women) attending the National Fire Service Academy for clinical training with ≥6 months field experience or having performed ≥10 CPR. Individuals who withdrew consent were excluded. OUTCOME MEASURES: CPR quality parameters (eg, chest compression depth and its variability). RESULTS: Chest compressions were performed for 8 min each in a stationary and driving state. The mean chest compression depths were 54.8 mm and 55.3 mm during these two states, respectively (p=0.41). The SD of the chest compression depth was significantly higher while in the driving (7.6 mm) than in the stationary state (6.5 mm; p=0.04). The compression depths in the speed bump and sudden stop sections were 51.5 mm and 50.6 mm, respectively, which was shallower than those in all other sections (p<0.001). The correct hand position rate was low in the speed bump, sudden stop and right-hand cornering sections (65.4%, 71.5% and 72.5%, respectively; p=0.001) CONCLUSIONS: Although we found no differences in chest compression quality parameters between the stationary and driving states, the variability in the chest compression depth increased in the driving state. When comparing CPR quality parameters according to driving patterns, we noted a shallower compression depth, increased variability and decreased correct hand position rate in the speed bump, sudden stop and right-hand cornering sections. The clinical significance of these changes in CPR quality during ambulance transport remains to be determined. Future studies on how to reduce changes in the quality of CPR (including research on equipment development) are needed. BMJ Publishing Group 2018-09-28 /pmc/articles/PMC6169751/ /pubmed/30269076 http://dx.doi.org/10.1136/bmjopen-2018-023784 Text en © Author(s) (or their employer(s)) 2018. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ. This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/.
spellingShingle Cardiovascular Medicine
Beom, Jin Ho
Kim, Min Joung
You, Je Sung
Lee, Hye Sun
Kim, Ji Hoon
Park, Yoo Seok
Shin, Dong Min
Chung, Hyun Soo
Evaluation of the quality of cardiopulmonary resuscitation according to vehicle driving pattern, using a virtual reality ambulance driving system: a prospective, cross-over, randomised study
title Evaluation of the quality of cardiopulmonary resuscitation according to vehicle driving pattern, using a virtual reality ambulance driving system: a prospective, cross-over, randomised study
title_full Evaluation of the quality of cardiopulmonary resuscitation according to vehicle driving pattern, using a virtual reality ambulance driving system: a prospective, cross-over, randomised study
title_fullStr Evaluation of the quality of cardiopulmonary resuscitation according to vehicle driving pattern, using a virtual reality ambulance driving system: a prospective, cross-over, randomised study
title_full_unstemmed Evaluation of the quality of cardiopulmonary resuscitation according to vehicle driving pattern, using a virtual reality ambulance driving system: a prospective, cross-over, randomised study
title_short Evaluation of the quality of cardiopulmonary resuscitation according to vehicle driving pattern, using a virtual reality ambulance driving system: a prospective, cross-over, randomised study
title_sort evaluation of the quality of cardiopulmonary resuscitation according to vehicle driving pattern, using a virtual reality ambulance driving system: a prospective, cross-over, randomised study
topic Cardiovascular Medicine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6169751/
https://www.ncbi.nlm.nih.gov/pubmed/30269076
http://dx.doi.org/10.1136/bmjopen-2018-023784
work_keys_str_mv AT beomjinho evaluationofthequalityofcardiopulmonaryresuscitationaccordingtovehicledrivingpatternusingavirtualrealityambulancedrivingsystemaprospectivecrossoverrandomisedstudy
AT kimminjoung evaluationofthequalityofcardiopulmonaryresuscitationaccordingtovehicledrivingpatternusingavirtualrealityambulancedrivingsystemaprospectivecrossoverrandomisedstudy
AT youjesung evaluationofthequalityofcardiopulmonaryresuscitationaccordingtovehicledrivingpatternusingavirtualrealityambulancedrivingsystemaprospectivecrossoverrandomisedstudy
AT leehyesun evaluationofthequalityofcardiopulmonaryresuscitationaccordingtovehicledrivingpatternusingavirtualrealityambulancedrivingsystemaprospectivecrossoverrandomisedstudy
AT kimjihoon evaluationofthequalityofcardiopulmonaryresuscitationaccordingtovehicledrivingpatternusingavirtualrealityambulancedrivingsystemaprospectivecrossoverrandomisedstudy
AT parkyooseok evaluationofthequalityofcardiopulmonaryresuscitationaccordingtovehicledrivingpatternusingavirtualrealityambulancedrivingsystemaprospectivecrossoverrandomisedstudy
AT shindongmin evaluationofthequalityofcardiopulmonaryresuscitationaccordingtovehicledrivingpatternusingavirtualrealityambulancedrivingsystemaprospectivecrossoverrandomisedstudy
AT chunghyunsoo evaluationofthequalityofcardiopulmonaryresuscitationaccordingtovehicledrivingpatternusingavirtualrealityambulancedrivingsystemaprospectivecrossoverrandomisedstudy