Cargando…
Feasibility and robustness of dynamic (18)F-FET PET based tracer kinetic models applied to patients with recurrent high-grade glioma prior to carbon ion irradiation
The aim of this study was to analyze the robustness and diagnostic value of different compartment models for dynamic (18)F-FET PET in recurrent high-grade glioma (HGG). Dynamic (18)F-FET PET data of patients with recurrent WHO grade III (n:7) and WHO grade IV (n: 9) tumors undergoing re-irradiation...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6170489/ https://www.ncbi.nlm.nih.gov/pubmed/30283013 http://dx.doi.org/10.1038/s41598-018-33034-5 |
_version_ | 1783360656522608640 |
---|---|
author | Debus, Charlotte Afshar-Oromieh, Ali Floca, Ralf Ingrisch, Michael Knoll, Maximilian Debus, Jürgen Haberkorn, Uwe Abdollahi, Amir |
author_facet | Debus, Charlotte Afshar-Oromieh, Ali Floca, Ralf Ingrisch, Michael Knoll, Maximilian Debus, Jürgen Haberkorn, Uwe Abdollahi, Amir |
author_sort | Debus, Charlotte |
collection | PubMed |
description | The aim of this study was to analyze the robustness and diagnostic value of different compartment models for dynamic (18)F-FET PET in recurrent high-grade glioma (HGG). Dynamic (18)F-FET PET data of patients with recurrent WHO grade III (n:7) and WHO grade IV (n: 9) tumors undergoing re-irradiation with carbon ions were analyzed by voxelwise fitting of the time-activity curves with a simplified and an extended one-tissue compartment model (1TCM) and a two-tissue compartment model (2TCM), respectively. A simulation study was conducted to assess robustness and precision of the 2TCM. Parameter maps showed enhanced detail on tumor substructure. Neglecting the blood volume V(B) in the 1TCM yields insufficient results. Parameter K(1) from both 1TCM and 2TCM showed correlation with overall patient survival after carbon ion irradiation (p = 0.043 and 0.036, respectively). The 2TCM yields realistic estimates for tumor blood volume, which was found to be significantly higher in WHO IV compared to WHO III (p = 0.031). Simulations on the 2TCM showed that K(1) yields good accuracy and robustness while k(2) showed lowest stability of all parameters. The 1TCM provides the best compromise between parameter stability and model accuracy; however application of the 2TCM is still feasible and provides a more accurate representation of tracer-kinetics at the cost of reduced robustness. Detailed tracer kinetic analysis of (18)F-FET PET with compartment models holds valuable information on tumor substructures and provides additional diagnostic and prognostic value. |
format | Online Article Text |
id | pubmed-6170489 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-61704892018-10-05 Feasibility and robustness of dynamic (18)F-FET PET based tracer kinetic models applied to patients with recurrent high-grade glioma prior to carbon ion irradiation Debus, Charlotte Afshar-Oromieh, Ali Floca, Ralf Ingrisch, Michael Knoll, Maximilian Debus, Jürgen Haberkorn, Uwe Abdollahi, Amir Sci Rep Article The aim of this study was to analyze the robustness and diagnostic value of different compartment models for dynamic (18)F-FET PET in recurrent high-grade glioma (HGG). Dynamic (18)F-FET PET data of patients with recurrent WHO grade III (n:7) and WHO grade IV (n: 9) tumors undergoing re-irradiation with carbon ions were analyzed by voxelwise fitting of the time-activity curves with a simplified and an extended one-tissue compartment model (1TCM) and a two-tissue compartment model (2TCM), respectively. A simulation study was conducted to assess robustness and precision of the 2TCM. Parameter maps showed enhanced detail on tumor substructure. Neglecting the blood volume V(B) in the 1TCM yields insufficient results. Parameter K(1) from both 1TCM and 2TCM showed correlation with overall patient survival after carbon ion irradiation (p = 0.043 and 0.036, respectively). The 2TCM yields realistic estimates for tumor blood volume, which was found to be significantly higher in WHO IV compared to WHO III (p = 0.031). Simulations on the 2TCM showed that K(1) yields good accuracy and robustness while k(2) showed lowest stability of all parameters. The 1TCM provides the best compromise between parameter stability and model accuracy; however application of the 2TCM is still feasible and provides a more accurate representation of tracer-kinetics at the cost of reduced robustness. Detailed tracer kinetic analysis of (18)F-FET PET with compartment models holds valuable information on tumor substructures and provides additional diagnostic and prognostic value. Nature Publishing Group UK 2018-10-03 /pmc/articles/PMC6170489/ /pubmed/30283013 http://dx.doi.org/10.1038/s41598-018-33034-5 Text en © The Author(s) 2018 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Debus, Charlotte Afshar-Oromieh, Ali Floca, Ralf Ingrisch, Michael Knoll, Maximilian Debus, Jürgen Haberkorn, Uwe Abdollahi, Amir Feasibility and robustness of dynamic (18)F-FET PET based tracer kinetic models applied to patients with recurrent high-grade glioma prior to carbon ion irradiation |
title | Feasibility and robustness of dynamic (18)F-FET PET based tracer kinetic models applied to patients with recurrent high-grade glioma prior to carbon ion irradiation |
title_full | Feasibility and robustness of dynamic (18)F-FET PET based tracer kinetic models applied to patients with recurrent high-grade glioma prior to carbon ion irradiation |
title_fullStr | Feasibility and robustness of dynamic (18)F-FET PET based tracer kinetic models applied to patients with recurrent high-grade glioma prior to carbon ion irradiation |
title_full_unstemmed | Feasibility and robustness of dynamic (18)F-FET PET based tracer kinetic models applied to patients with recurrent high-grade glioma prior to carbon ion irradiation |
title_short | Feasibility and robustness of dynamic (18)F-FET PET based tracer kinetic models applied to patients with recurrent high-grade glioma prior to carbon ion irradiation |
title_sort | feasibility and robustness of dynamic (18)f-fet pet based tracer kinetic models applied to patients with recurrent high-grade glioma prior to carbon ion irradiation |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6170489/ https://www.ncbi.nlm.nih.gov/pubmed/30283013 http://dx.doi.org/10.1038/s41598-018-33034-5 |
work_keys_str_mv | AT debuscharlotte feasibilityandrobustnessofdynamic18ffetpetbasedtracerkineticmodelsappliedtopatientswithrecurrenthighgradegliomapriortocarbonionirradiation AT afsharoromiehali feasibilityandrobustnessofdynamic18ffetpetbasedtracerkineticmodelsappliedtopatientswithrecurrenthighgradegliomapriortocarbonionirradiation AT flocaralf feasibilityandrobustnessofdynamic18ffetpetbasedtracerkineticmodelsappliedtopatientswithrecurrenthighgradegliomapriortocarbonionirradiation AT ingrischmichael feasibilityandrobustnessofdynamic18ffetpetbasedtracerkineticmodelsappliedtopatientswithrecurrenthighgradegliomapriortocarbonionirradiation AT knollmaximilian feasibilityandrobustnessofdynamic18ffetpetbasedtracerkineticmodelsappliedtopatientswithrecurrenthighgradegliomapriortocarbonionirradiation AT debusjurgen feasibilityandrobustnessofdynamic18ffetpetbasedtracerkineticmodelsappliedtopatientswithrecurrenthighgradegliomapriortocarbonionirradiation AT haberkornuwe feasibilityandrobustnessofdynamic18ffetpetbasedtracerkineticmodelsappliedtopatientswithrecurrenthighgradegliomapriortocarbonionirradiation AT abdollahiamir feasibilityandrobustnessofdynamic18ffetpetbasedtracerkineticmodelsappliedtopatientswithrecurrenthighgradegliomapriortocarbonionirradiation |