Cargando…

A Pilot Study on the Comparison between Planning Target Volume-based Intensity-Modulated Proton Therapy Plans and Robustly Optimized Intensity-Modulated Proton Therapy Plans

The objective of this work is to compare the planning target volume (PTV)-based intensity-modulated proton therapy (IMPT) plans with robustly optimized IMPT plans using the robust optimization tools available in Pinnacle Treatment Planning System. We performed the study in five cases of different an...

Descripción completa

Detalles Bibliográficos
Autores principales: Perumal, Bojarajan, Sundaresan, Harikrishna Etti, Vaitheeswaran, Ranganathan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6172866/
https://www.ncbi.nlm.nih.gov/pubmed/30305776
http://dx.doi.org/10.4103/jmp.JMP_45_18
_version_ 1783361028281597952
author Perumal, Bojarajan
Sundaresan, Harikrishna Etti
Vaitheeswaran, Ranganathan
author_facet Perumal, Bojarajan
Sundaresan, Harikrishna Etti
Vaitheeswaran, Ranganathan
author_sort Perumal, Bojarajan
collection PubMed
description The objective of this work is to compare the planning target volume (PTV)-based intensity-modulated proton therapy (IMPT) plans with robustly optimized IMPT plans using the robust optimization tools available in Pinnacle Treatment Planning System. We performed the study in five cases of different anatomic sites (brain, head and neck, lung, pancreas, and prostate). Pinnacle IMPT nonclinical version was used for IMPT planning. Two types of IMPT plans were created for each case. One is PTV-based conventionally optimized IMPT plan and the other is robustly optimized plan considering setup uncertainties. For the PTV-based plans, margins were on top of clinical target volume (CTV) to account for the setup errors, whereas in the robustly optimized plan, the setup errors were directly incorporated into the optimization process. The plan evaluation included target (CTV) coverage and dose uniformity. Our interest was to see how the target coverage and dose uniformity were perturbed on imposing setup errors in +X, −X, +Y, −Y, +Z, and −Z directions for both PTV-based and robust optimization (RO)-based plans. On the average, RO-based IMPT plans have shown a good consistency of target coverage and dose uniformity for all six setup errors scenarios as compared to PTV-based plans. In addition, RO-based plans have a better target coverage and dose uniformity under uncertainty conditions as compared to the PTV-based plans. The study demonstrates the superiority of robustly optimized IMPT plans over the PTV-based IMPT plans in terms of dose distribution under the uncertainty conditions.
format Online
Article
Text
id pubmed-6172866
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-61728662018-10-10 A Pilot Study on the Comparison between Planning Target Volume-based Intensity-Modulated Proton Therapy Plans and Robustly Optimized Intensity-Modulated Proton Therapy Plans Perumal, Bojarajan Sundaresan, Harikrishna Etti Vaitheeswaran, Ranganathan J Med Phys Technical Note The objective of this work is to compare the planning target volume (PTV)-based intensity-modulated proton therapy (IMPT) plans with robustly optimized IMPT plans using the robust optimization tools available in Pinnacle Treatment Planning System. We performed the study in five cases of different anatomic sites (brain, head and neck, lung, pancreas, and prostate). Pinnacle IMPT nonclinical version was used for IMPT planning. Two types of IMPT plans were created for each case. One is PTV-based conventionally optimized IMPT plan and the other is robustly optimized plan considering setup uncertainties. For the PTV-based plans, margins were on top of clinical target volume (CTV) to account for the setup errors, whereas in the robustly optimized plan, the setup errors were directly incorporated into the optimization process. The plan evaluation included target (CTV) coverage and dose uniformity. Our interest was to see how the target coverage and dose uniformity were perturbed on imposing setup errors in +X, −X, +Y, −Y, +Z, and −Z directions for both PTV-based and robust optimization (RO)-based plans. On the average, RO-based IMPT plans have shown a good consistency of target coverage and dose uniformity for all six setup errors scenarios as compared to PTV-based plans. In addition, RO-based plans have a better target coverage and dose uniformity under uncertainty conditions as compared to the PTV-based plans. The study demonstrates the superiority of robustly optimized IMPT plans over the PTV-based IMPT plans in terms of dose distribution under the uncertainty conditions. Medknow Publications & Media Pvt Ltd 2018 /pmc/articles/PMC6172866/ /pubmed/30305776 http://dx.doi.org/10.4103/jmp.JMP_45_18 Text en Copyright: © 2018 Journal of Medical Physics http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Technical Note
Perumal, Bojarajan
Sundaresan, Harikrishna Etti
Vaitheeswaran, Ranganathan
A Pilot Study on the Comparison between Planning Target Volume-based Intensity-Modulated Proton Therapy Plans and Robustly Optimized Intensity-Modulated Proton Therapy Plans
title A Pilot Study on the Comparison between Planning Target Volume-based Intensity-Modulated Proton Therapy Plans and Robustly Optimized Intensity-Modulated Proton Therapy Plans
title_full A Pilot Study on the Comparison between Planning Target Volume-based Intensity-Modulated Proton Therapy Plans and Robustly Optimized Intensity-Modulated Proton Therapy Plans
title_fullStr A Pilot Study on the Comparison between Planning Target Volume-based Intensity-Modulated Proton Therapy Plans and Robustly Optimized Intensity-Modulated Proton Therapy Plans
title_full_unstemmed A Pilot Study on the Comparison between Planning Target Volume-based Intensity-Modulated Proton Therapy Plans and Robustly Optimized Intensity-Modulated Proton Therapy Plans
title_short A Pilot Study on the Comparison between Planning Target Volume-based Intensity-Modulated Proton Therapy Plans and Robustly Optimized Intensity-Modulated Proton Therapy Plans
title_sort pilot study on the comparison between planning target volume-based intensity-modulated proton therapy plans and robustly optimized intensity-modulated proton therapy plans
topic Technical Note
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6172866/
https://www.ncbi.nlm.nih.gov/pubmed/30305776
http://dx.doi.org/10.4103/jmp.JMP_45_18
work_keys_str_mv AT perumalbojarajan apilotstudyonthecomparisonbetweenplanningtargetvolumebasedintensitymodulatedprotontherapyplansandrobustlyoptimizedintensitymodulatedprotontherapyplans
AT sundaresanharikrishnaetti apilotstudyonthecomparisonbetweenplanningtargetvolumebasedintensitymodulatedprotontherapyplansandrobustlyoptimizedintensitymodulatedprotontherapyplans
AT vaitheeswaranranganathan apilotstudyonthecomparisonbetweenplanningtargetvolumebasedintensitymodulatedprotontherapyplansandrobustlyoptimizedintensitymodulatedprotontherapyplans
AT perumalbojarajan pilotstudyonthecomparisonbetweenplanningtargetvolumebasedintensitymodulatedprotontherapyplansandrobustlyoptimizedintensitymodulatedprotontherapyplans
AT sundaresanharikrishnaetti pilotstudyonthecomparisonbetweenplanningtargetvolumebasedintensitymodulatedprotontherapyplansandrobustlyoptimizedintensitymodulatedprotontherapyplans
AT vaitheeswaranranganathan pilotstudyonthecomparisonbetweenplanningtargetvolumebasedintensitymodulatedprotontherapyplansandrobustlyoptimizedintensitymodulatedprotontherapyplans