Cargando…

The effect of modified locking methods and suture materials on Zone II flexor tendon repair—An ex vivo study

The failure rate of intrasynovial tendon repair is high due to substantial elongation at the repair site and to the development of adhesions between the tendon’s surface and the surrounding digital sheath. To minimize these complications, we sought to reduce the incidence of gapping and to facilitat...

Descripción completa

Detalles Bibliográficos
Autores principales: Yoneda, Susumu, Okubo, Hirotaka, Linderman, Stephen W., Kusano, Nozomu, Silva, Matthew J., Thomopoulos, Stavros, Kanaya, Fuminori, Gelberman, Richard H.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6173425/
https://www.ncbi.nlm.nih.gov/pubmed/30289887
http://dx.doi.org/10.1371/journal.pone.0205121
_version_ 1783361126847741952
author Yoneda, Susumu
Okubo, Hirotaka
Linderman, Stephen W.
Kusano, Nozomu
Silva, Matthew J.
Thomopoulos, Stavros
Kanaya, Fuminori
Gelberman, Richard H.
author_facet Yoneda, Susumu
Okubo, Hirotaka
Linderman, Stephen W.
Kusano, Nozomu
Silva, Matthew J.
Thomopoulos, Stavros
Kanaya, Fuminori
Gelberman, Richard H.
author_sort Yoneda, Susumu
collection PubMed
description The failure rate of intrasynovial tendon repair is high due to substantial elongation at the repair site and to the development of adhesions between the tendon’s surface and the surrounding digital sheath. To minimize these complications, we sought to reduce the incidence of gapping and to facilitate the initiation of early motion by improving the time zero structural properties of repair. The Winters-Gelberman 8-strand repair technique was modified by adding surface lock loops and by using Fiberwire suture material. Forty-eight canine flexor digitorum profundus tendons were transected and repaired with one of three 8-strand techniques (Pennington modified Kessler, half hitch loops, or surface locking Kessler) using either 3–0 Supramid or 4–0 Fiberwire suture. Biomechanical testing was performed to determine the physiologic and failure mode properties of the repairs. The surface locking Kessler technique improved repair maximum load, load necessary to create a 2 mm repair site gap, and yield force compared to the modified Kessler and half hitch loop techniques. Fiberwire suture improved maximum load, the load necessary to create a 2 mm repair site gap, stiffness, and yield force compared to Supramid suture. Failure occurred by both suture pull out and by suture breakage in the modified Kessler, Supramid suture repair group. Failure occurred consistently by suture breakage in the surface locking Kessler, Supramid suture repair group. These results reveal that a novel locking Kessler repair is significantly stronger than the current state-of-the art flexor tendon suture repair technique. The use of a surface locking Kessler technique with Fiberwire suture markedly improves the mechanical properties of intrasynovial tendon repair by reducing the risk of post-operative gapping and rupture.
format Online
Article
Text
id pubmed-6173425
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-61734252018-10-19 The effect of modified locking methods and suture materials on Zone II flexor tendon repair—An ex vivo study Yoneda, Susumu Okubo, Hirotaka Linderman, Stephen W. Kusano, Nozomu Silva, Matthew J. Thomopoulos, Stavros Kanaya, Fuminori Gelberman, Richard H. PLoS One Research Article The failure rate of intrasynovial tendon repair is high due to substantial elongation at the repair site and to the development of adhesions between the tendon’s surface and the surrounding digital sheath. To minimize these complications, we sought to reduce the incidence of gapping and to facilitate the initiation of early motion by improving the time zero structural properties of repair. The Winters-Gelberman 8-strand repair technique was modified by adding surface lock loops and by using Fiberwire suture material. Forty-eight canine flexor digitorum profundus tendons were transected and repaired with one of three 8-strand techniques (Pennington modified Kessler, half hitch loops, or surface locking Kessler) using either 3–0 Supramid or 4–0 Fiberwire suture. Biomechanical testing was performed to determine the physiologic and failure mode properties of the repairs. The surface locking Kessler technique improved repair maximum load, load necessary to create a 2 mm repair site gap, and yield force compared to the modified Kessler and half hitch loop techniques. Fiberwire suture improved maximum load, the load necessary to create a 2 mm repair site gap, stiffness, and yield force compared to Supramid suture. Failure occurred by both suture pull out and by suture breakage in the modified Kessler, Supramid suture repair group. Failure occurred consistently by suture breakage in the surface locking Kessler, Supramid suture repair group. These results reveal that a novel locking Kessler repair is significantly stronger than the current state-of-the art flexor tendon suture repair technique. The use of a surface locking Kessler technique with Fiberwire suture markedly improves the mechanical properties of intrasynovial tendon repair by reducing the risk of post-operative gapping and rupture. Public Library of Science 2018-10-05 /pmc/articles/PMC6173425/ /pubmed/30289887 http://dx.doi.org/10.1371/journal.pone.0205121 Text en © 2018 Yoneda et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Yoneda, Susumu
Okubo, Hirotaka
Linderman, Stephen W.
Kusano, Nozomu
Silva, Matthew J.
Thomopoulos, Stavros
Kanaya, Fuminori
Gelberman, Richard H.
The effect of modified locking methods and suture materials on Zone II flexor tendon repair—An ex vivo study
title The effect of modified locking methods and suture materials on Zone II flexor tendon repair—An ex vivo study
title_full The effect of modified locking methods and suture materials on Zone II flexor tendon repair—An ex vivo study
title_fullStr The effect of modified locking methods and suture materials on Zone II flexor tendon repair—An ex vivo study
title_full_unstemmed The effect of modified locking methods and suture materials on Zone II flexor tendon repair—An ex vivo study
title_short The effect of modified locking methods and suture materials on Zone II flexor tendon repair—An ex vivo study
title_sort effect of modified locking methods and suture materials on zone ii flexor tendon repair—an ex vivo study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6173425/
https://www.ncbi.nlm.nih.gov/pubmed/30289887
http://dx.doi.org/10.1371/journal.pone.0205121
work_keys_str_mv AT yonedasusumu theeffectofmodifiedlockingmethodsandsuturematerialsonzoneiiflexortendonrepairanexvivostudy
AT okubohirotaka theeffectofmodifiedlockingmethodsandsuturematerialsonzoneiiflexortendonrepairanexvivostudy
AT lindermanstephenw theeffectofmodifiedlockingmethodsandsuturematerialsonzoneiiflexortendonrepairanexvivostudy
AT kusanonozomu theeffectofmodifiedlockingmethodsandsuturematerialsonzoneiiflexortendonrepairanexvivostudy
AT silvamatthewj theeffectofmodifiedlockingmethodsandsuturematerialsonzoneiiflexortendonrepairanexvivostudy
AT thomopoulosstavros theeffectofmodifiedlockingmethodsandsuturematerialsonzoneiiflexortendonrepairanexvivostudy
AT kanayafuminori theeffectofmodifiedlockingmethodsandsuturematerialsonzoneiiflexortendonrepairanexvivostudy
AT gelbermanrichardh theeffectofmodifiedlockingmethodsandsuturematerialsonzoneiiflexortendonrepairanexvivostudy
AT yonedasusumu effectofmodifiedlockingmethodsandsuturematerialsonzoneiiflexortendonrepairanexvivostudy
AT okubohirotaka effectofmodifiedlockingmethodsandsuturematerialsonzoneiiflexortendonrepairanexvivostudy
AT lindermanstephenw effectofmodifiedlockingmethodsandsuturematerialsonzoneiiflexortendonrepairanexvivostudy
AT kusanonozomu effectofmodifiedlockingmethodsandsuturematerialsonzoneiiflexortendonrepairanexvivostudy
AT silvamatthewj effectofmodifiedlockingmethodsandsuturematerialsonzoneiiflexortendonrepairanexvivostudy
AT thomopoulosstavros effectofmodifiedlockingmethodsandsuturematerialsonzoneiiflexortendonrepairanexvivostudy
AT kanayafuminori effectofmodifiedlockingmethodsandsuturematerialsonzoneiiflexortendonrepairanexvivostudy
AT gelbermanrichardh effectofmodifiedlockingmethodsandsuturematerialsonzoneiiflexortendonrepairanexvivostudy