Thoracic Organ Doses and Cancer Risk from Low Pitch Helical 4-Dimensional Computed Tomography Scans

PURPOSE: To investigate the dose depositions to organs at risk (OARs) and associated cancer risk in cancer patients scanned with 4-dimensional computed tomography (4DCT) as compared with conventional 3DCT. METHODS AND MATERIALS: The radiotherapy treatment planning CT image and structure sets of 102...

Descripción completa

Detalles Bibliográficos
Autores principales: Yang, Chengwen, Liu, Ransheng, Ming, Xin, Liu, Ningbo, Guan, Yong, Feng, Yuanming
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6174794/
https://www.ncbi.nlm.nih.gov/pubmed/30345309
http://dx.doi.org/10.1155/2018/8927290
_version_ 1783361345591181312
author Yang, Chengwen
Liu, Ransheng
Ming, Xin
Liu, Ningbo
Guan, Yong
Feng, Yuanming
author_facet Yang, Chengwen
Liu, Ransheng
Ming, Xin
Liu, Ningbo
Guan, Yong
Feng, Yuanming
author_sort Yang, Chengwen
collection PubMed
description PURPOSE: To investigate the dose depositions to organs at risk (OARs) and associated cancer risk in cancer patients scanned with 4-dimensional computed tomography (4DCT) as compared with conventional 3DCT. METHODS AND MATERIALS: The radiotherapy treatment planning CT image and structure sets of 102 patients were converted to CT phantoms. The effective diameters of those patients were computed. Thoracic scan protocols in 4DCT and 3DCT were simulated and verified with a validated Monte Carlo code. The doses to OARs (heart, lungs, esophagus, trachea, spinal cord, and skin) were calculated and their correlations with patient effective diameter were investigated. The associated cancer risk was calculated using the published models in BEIR VII reports. RESULTS: The average of mean dose to thoracic organs was in the range of 7.82-11.84 cGy per 4DCT scan and 0.64-0.85 cGy per 3DCT scan. The average dose delivered per 4DCT scan was 12.8-fold higher than that of 3DCT scan. The organ dose was linearly decreased as the function of patients' effective diameter. The ranges of intercept and slope of the linear function were 17.17-30.95 and -0.0278--0.0576 among patients' 4DCT scans, and 1.63-2.43 and -0.003--0.0045 among patients' 3DCT scans. Relative risk of cancer increased (with a ratio of 15.68:1) resulting from 4DCT scans as compared to 3DCT scans. CONCLUSIONS: As compared to 3DCT, 4DCT scans deliver more organ doses, especially for pediatric patients. Substantial increase in lung cancer risk is associated with higher radiation dose from 4DCT and smaller patients' size as well as younger age.
format Online
Article
Text
id pubmed-6174794
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-61747942018-10-21 Thoracic Organ Doses and Cancer Risk from Low Pitch Helical 4-Dimensional Computed Tomography Scans Yang, Chengwen Liu, Ransheng Ming, Xin Liu, Ningbo Guan, Yong Feng, Yuanming Biomed Res Int Research Article PURPOSE: To investigate the dose depositions to organs at risk (OARs) and associated cancer risk in cancer patients scanned with 4-dimensional computed tomography (4DCT) as compared with conventional 3DCT. METHODS AND MATERIALS: The radiotherapy treatment planning CT image and structure sets of 102 patients were converted to CT phantoms. The effective diameters of those patients were computed. Thoracic scan protocols in 4DCT and 3DCT were simulated and verified with a validated Monte Carlo code. The doses to OARs (heart, lungs, esophagus, trachea, spinal cord, and skin) were calculated and their correlations with patient effective diameter were investigated. The associated cancer risk was calculated using the published models in BEIR VII reports. RESULTS: The average of mean dose to thoracic organs was in the range of 7.82-11.84 cGy per 4DCT scan and 0.64-0.85 cGy per 3DCT scan. The average dose delivered per 4DCT scan was 12.8-fold higher than that of 3DCT scan. The organ dose was linearly decreased as the function of patients' effective diameter. The ranges of intercept and slope of the linear function were 17.17-30.95 and -0.0278--0.0576 among patients' 4DCT scans, and 1.63-2.43 and -0.003--0.0045 among patients' 3DCT scans. Relative risk of cancer increased (with a ratio of 15.68:1) resulting from 4DCT scans as compared to 3DCT scans. CONCLUSIONS: As compared to 3DCT, 4DCT scans deliver more organ doses, especially for pediatric patients. Substantial increase in lung cancer risk is associated with higher radiation dose from 4DCT and smaller patients' size as well as younger age. Hindawi 2018-09-24 /pmc/articles/PMC6174794/ /pubmed/30345309 http://dx.doi.org/10.1155/2018/8927290 Text en Copyright © 2018 Chengwen Yang et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Yang, Chengwen
Liu, Ransheng
Ming, Xin
Liu, Ningbo
Guan, Yong
Feng, Yuanming
Thoracic Organ Doses and Cancer Risk from Low Pitch Helical 4-Dimensional Computed Tomography Scans
title Thoracic Organ Doses and Cancer Risk from Low Pitch Helical 4-Dimensional Computed Tomography Scans
title_full Thoracic Organ Doses and Cancer Risk from Low Pitch Helical 4-Dimensional Computed Tomography Scans
title_fullStr Thoracic Organ Doses and Cancer Risk from Low Pitch Helical 4-Dimensional Computed Tomography Scans
title_full_unstemmed Thoracic Organ Doses and Cancer Risk from Low Pitch Helical 4-Dimensional Computed Tomography Scans
title_short Thoracic Organ Doses and Cancer Risk from Low Pitch Helical 4-Dimensional Computed Tomography Scans
title_sort thoracic organ doses and cancer risk from low pitch helical 4-dimensional computed tomography scans
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6174794/
https://www.ncbi.nlm.nih.gov/pubmed/30345309
http://dx.doi.org/10.1155/2018/8927290
work_keys_str_mv AT yangchengwen thoracicorgandosesandcancerriskfromlowpitchhelical4dimensionalcomputedtomographyscans
AT liuransheng thoracicorgandosesandcancerriskfromlowpitchhelical4dimensionalcomputedtomographyscans
AT mingxin thoracicorgandosesandcancerriskfromlowpitchhelical4dimensionalcomputedtomographyscans
AT liuningbo thoracicorgandosesandcancerriskfromlowpitchhelical4dimensionalcomputedtomographyscans
AT guanyong thoracicorgandosesandcancerriskfromlowpitchhelical4dimensionalcomputedtomographyscans
AT fengyuanming thoracicorgandosesandcancerriskfromlowpitchhelical4dimensionalcomputedtomographyscans