Improving High-resolution Impedance Manometry Using Novel Viscous and Super-viscous Substrates in the Supine and Upright Positions: A Pilot Study

BACKGROUND/AIMS: Swallows with viscous or solid boluses in different body positions alter esophageal manometry patterns. Limitations of previous studies include lack of standardized viscous substrates and the need for chewing prior to swallowing solid boluses. We hypothesize that high-resolution imp...

Descripción completa

Detalles Bibliográficos
Autores principales: Wong, Uni, Person, Erik B, Castell, Donald O, von Rosenvinge, Erik, Raufman, Jean-Pierre, Xie, Guofeng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Society of Neurogastroenterology and Motility 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6175560/
https://www.ncbi.nlm.nih.gov/pubmed/30122029
http://dx.doi.org/10.5056/jnm18010
Descripción
Sumario:BACKGROUND/AIMS: Swallows with viscous or solid boluses in different body positions alter esophageal manometry patterns. Limitations of previous studies include lack of standardized viscous substrates and the need for chewing prior to swallowing solid boluses. We hypothesize that high-resolution impedance manometry (HRiM) using standardized viscous and super-viscous swallows in supine and upright positions improves sensitivity for detecting esophageal motility abnormalities when compared with traditional saline swallows. To establish normative values for these novel substrates, we recruited healthy volunteers and performed HRiM. METHODS: Standardized viscous and super-viscous substrates were prepared using “Thick-It” food thickener and a rotational viscometer. All swallows were administered in 5-mL increments in both supine and upright positions. HRiM metrics and impedance (bolus transit) were calculated. We used a paired two-tailed t test to compare all metrics by position and substrate. RESULTS: The 5-g, 7-g, and 10-g substrates measured 5000, 36 200, and 64 700 mPa sec, respectively. In 18 volunteers, we observed that the integrated relaxation pressure was lower when upright than when supine for all substrates (P < 0.01). The 10-g substrate significantly increased integrated relaxation pressure when compared to saline in the supine position (P < 0.01). Substrates and positions also affected distal contractile integral, distal latency, and impedance values. CONCLUSIONS: We examined HRiM values using novel standardized viscous and super-viscous substrates in healthy subjects for both supine and upright positions. We found that viscosity and position affected HRiM Chicago metrics and have potential to increase the sensitivity of esophageal manometry.