Cargando…
Improving High-resolution Impedance Manometry Using Novel Viscous and Super-viscous Substrates in the Supine and Upright Positions: A Pilot Study
BACKGROUND/AIMS: Swallows with viscous or solid boluses in different body positions alter esophageal manometry patterns. Limitations of previous studies include lack of standardized viscous substrates and the need for chewing prior to swallowing solid boluses. We hypothesize that high-resolution imp...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Society of Neurogastroenterology and Motility
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6175560/ https://www.ncbi.nlm.nih.gov/pubmed/30122029 http://dx.doi.org/10.5056/jnm18010 |
_version_ | 1783361541672796160 |
---|---|
author | Wong, Uni Person, Erik B Castell, Donald O von Rosenvinge, Erik Raufman, Jean-Pierre Xie, Guofeng |
author_facet | Wong, Uni Person, Erik B Castell, Donald O von Rosenvinge, Erik Raufman, Jean-Pierre Xie, Guofeng |
author_sort | Wong, Uni |
collection | PubMed |
description | BACKGROUND/AIMS: Swallows with viscous or solid boluses in different body positions alter esophageal manometry patterns. Limitations of previous studies include lack of standardized viscous substrates and the need for chewing prior to swallowing solid boluses. We hypothesize that high-resolution impedance manometry (HRiM) using standardized viscous and super-viscous swallows in supine and upright positions improves sensitivity for detecting esophageal motility abnormalities when compared with traditional saline swallows. To establish normative values for these novel substrates, we recruited healthy volunteers and performed HRiM. METHODS: Standardized viscous and super-viscous substrates were prepared using “Thick-It” food thickener and a rotational viscometer. All swallows were administered in 5-mL increments in both supine and upright positions. HRiM metrics and impedance (bolus transit) were calculated. We used a paired two-tailed t test to compare all metrics by position and substrate. RESULTS: The 5-g, 7-g, and 10-g substrates measured 5000, 36 200, and 64 700 mPa sec, respectively. In 18 volunteers, we observed that the integrated relaxation pressure was lower when upright than when supine for all substrates (P < 0.01). The 10-g substrate significantly increased integrated relaxation pressure when compared to saline in the supine position (P < 0.01). Substrates and positions also affected distal contractile integral, distal latency, and impedance values. CONCLUSIONS: We examined HRiM values using novel standardized viscous and super-viscous substrates in healthy subjects for both supine and upright positions. We found that viscosity and position affected HRiM Chicago metrics and have potential to increase the sensitivity of esophageal manometry. |
format | Online Article Text |
id | pubmed-6175560 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Korean Society of Neurogastroenterology and Motility |
record_format | MEDLINE/PubMed |
spelling | pubmed-61755602018-10-17 Improving High-resolution Impedance Manometry Using Novel Viscous and Super-viscous Substrates in the Supine and Upright Positions: A Pilot Study Wong, Uni Person, Erik B Castell, Donald O von Rosenvinge, Erik Raufman, Jean-Pierre Xie, Guofeng J Neurogastroenterol Motil Original Article BACKGROUND/AIMS: Swallows with viscous or solid boluses in different body positions alter esophageal manometry patterns. Limitations of previous studies include lack of standardized viscous substrates and the need for chewing prior to swallowing solid boluses. We hypothesize that high-resolution impedance manometry (HRiM) using standardized viscous and super-viscous swallows in supine and upright positions improves sensitivity for detecting esophageal motility abnormalities when compared with traditional saline swallows. To establish normative values for these novel substrates, we recruited healthy volunteers and performed HRiM. METHODS: Standardized viscous and super-viscous substrates were prepared using “Thick-It” food thickener and a rotational viscometer. All swallows were administered in 5-mL increments in both supine and upright positions. HRiM metrics and impedance (bolus transit) were calculated. We used a paired two-tailed t test to compare all metrics by position and substrate. RESULTS: The 5-g, 7-g, and 10-g substrates measured 5000, 36 200, and 64 700 mPa sec, respectively. In 18 volunteers, we observed that the integrated relaxation pressure was lower when upright than when supine for all substrates (P < 0.01). The 10-g substrate significantly increased integrated relaxation pressure when compared to saline in the supine position (P < 0.01). Substrates and positions also affected distal contractile integral, distal latency, and impedance values. CONCLUSIONS: We examined HRiM values using novel standardized viscous and super-viscous substrates in healthy subjects for both supine and upright positions. We found that viscosity and position affected HRiM Chicago metrics and have potential to increase the sensitivity of esophageal manometry. Korean Society of Neurogastroenterology and Motility 2018-10 2018-10-01 /pmc/articles/PMC6175560/ /pubmed/30122029 http://dx.doi.org/10.5056/jnm18010 Text en © 2018 The Korean Society of Neurogastroenterology and Motility This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Wong, Uni Person, Erik B Castell, Donald O von Rosenvinge, Erik Raufman, Jean-Pierre Xie, Guofeng Improving High-resolution Impedance Manometry Using Novel Viscous and Super-viscous Substrates in the Supine and Upright Positions: A Pilot Study |
title | Improving High-resolution Impedance Manometry Using Novel Viscous and Super-viscous Substrates in the Supine and Upright Positions: A Pilot Study |
title_full | Improving High-resolution Impedance Manometry Using Novel Viscous and Super-viscous Substrates in the Supine and Upright Positions: A Pilot Study |
title_fullStr | Improving High-resolution Impedance Manometry Using Novel Viscous and Super-viscous Substrates in the Supine and Upright Positions: A Pilot Study |
title_full_unstemmed | Improving High-resolution Impedance Manometry Using Novel Viscous and Super-viscous Substrates in the Supine and Upright Positions: A Pilot Study |
title_short | Improving High-resolution Impedance Manometry Using Novel Viscous and Super-viscous Substrates in the Supine and Upright Positions: A Pilot Study |
title_sort | improving high-resolution impedance manometry using novel viscous and super-viscous substrates in the supine and upright positions: a pilot study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6175560/ https://www.ncbi.nlm.nih.gov/pubmed/30122029 http://dx.doi.org/10.5056/jnm18010 |
work_keys_str_mv | AT wonguni improvinghighresolutionimpedancemanometryusingnovelviscousandsuperviscoussubstratesinthesupineanduprightpositionsapilotstudy AT personerikb improvinghighresolutionimpedancemanometryusingnovelviscousandsuperviscoussubstratesinthesupineanduprightpositionsapilotstudy AT castelldonaldo improvinghighresolutionimpedancemanometryusingnovelviscousandsuperviscoussubstratesinthesupineanduprightpositionsapilotstudy AT vonrosenvingeerik improvinghighresolutionimpedancemanometryusingnovelviscousandsuperviscoussubstratesinthesupineanduprightpositionsapilotstudy AT raufmanjeanpierre improvinghighresolutionimpedancemanometryusingnovelviscousandsuperviscoussubstratesinthesupineanduprightpositionsapilotstudy AT xieguofeng improvinghighresolutionimpedancemanometryusingnovelviscousandsuperviscoussubstratesinthesupineanduprightpositionsapilotstudy |