Cargando…

Critical Appraisal of the Treatment Planning Performance of Volumetric Modulated Arc Therapy by Means of a Dual Layer Stacked Multileaf Collimator for Head and Neck, Breast, and Prostate

PURPOSE: To ascertain whether a new delivery system (the Halcyon system) equipped with dual-layer stacked multileaf collimator operating in a mode, which allows independent, fully interdigitating motion of both layers and 6 flattening filter free energy, could generate plans of high clinical quality...

Descripción completa

Detalles Bibliográficos
Autores principales: Cozzi, Luca, Fogliata, Antonella, Thompson, Stephen, Franzese, Ciro, Franceschini, Davide, de Rose, Fiorenza, Tomatis, Stefano, Scorsetti, Marta
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6176542/
https://www.ncbi.nlm.nih.gov/pubmed/30295172
http://dx.doi.org/10.1177/1533033818803882
_version_ 1783361724112437248
author Cozzi, Luca
Fogliata, Antonella
Thompson, Stephen
Franzese, Ciro
Franceschini, Davide
de Rose, Fiorenza
Tomatis, Stefano
Scorsetti, Marta
author_facet Cozzi, Luca
Fogliata, Antonella
Thompson, Stephen
Franzese, Ciro
Franceschini, Davide
de Rose, Fiorenza
Tomatis, Stefano
Scorsetti, Marta
author_sort Cozzi, Luca
collection PubMed
description PURPOSE: To ascertain whether a new delivery system (the Halcyon system) equipped with dual-layer stacked multileaf collimator operating in a mode, which allows independent, fully interdigitating motion of both layers and 6 flattening filter free energy, could generate plans of high clinical quality compared to a well-established delivery system with single layer multileaf collimator. METHODS: Twenty patients in each of the 3 groups (advanced head and neck, breast, and high-risk prostate) were selected for an in silico planning study. For each patient, reference plans were developed for volumetric modulated arc therapy technique with 6 MV photon beams from a TrueBeam linear accelerator and compared against the corresponding plans for the Halcyon system. Plan comparison was performed in terms of dose volume histogram quantitative analysis. RESULTS: Concerning the planning target volumes, with identical dose calculation and optimization algorithms and with identical planning techniques, no clinically relevant difference in coverage (D(98%)), hot spot (D(2%)), or homogeneity was observed. Similarly, for all the organs at risk, the dosimetric findings showed that (1) all planning constraints were met by the 2 delivery systems and (2) although statistical significant differences were reported for most of the parameters but none of these were judged of potential clinical relevance. CONCLUSION: The data presented confirmed that the new delivery system can generate treatment plans for volumetric modulated arc therapy with the same dosimetric quality of what is achievable with other systems routinely used in the clinics without significantly changing the current practice. Additional studies which customize the optimization parameters for each delivery device would complement the spectrum of investigations.
format Online
Article
Text
id pubmed-6176542
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-61765422018-10-10 Critical Appraisal of the Treatment Planning Performance of Volumetric Modulated Arc Therapy by Means of a Dual Layer Stacked Multileaf Collimator for Head and Neck, Breast, and Prostate Cozzi, Luca Fogliata, Antonella Thompson, Stephen Franzese, Ciro Franceschini, Davide de Rose, Fiorenza Tomatis, Stefano Scorsetti, Marta Technol Cancer Res Treat Original Article PURPOSE: To ascertain whether a new delivery system (the Halcyon system) equipped with dual-layer stacked multileaf collimator operating in a mode, which allows independent, fully interdigitating motion of both layers and 6 flattening filter free energy, could generate plans of high clinical quality compared to a well-established delivery system with single layer multileaf collimator. METHODS: Twenty patients in each of the 3 groups (advanced head and neck, breast, and high-risk prostate) were selected for an in silico planning study. For each patient, reference plans were developed for volumetric modulated arc therapy technique with 6 MV photon beams from a TrueBeam linear accelerator and compared against the corresponding plans for the Halcyon system. Plan comparison was performed in terms of dose volume histogram quantitative analysis. RESULTS: Concerning the planning target volumes, with identical dose calculation and optimization algorithms and with identical planning techniques, no clinically relevant difference in coverage (D(98%)), hot spot (D(2%)), or homogeneity was observed. Similarly, for all the organs at risk, the dosimetric findings showed that (1) all planning constraints were met by the 2 delivery systems and (2) although statistical significant differences were reported for most of the parameters but none of these were judged of potential clinical relevance. CONCLUSION: The data presented confirmed that the new delivery system can generate treatment plans for volumetric modulated arc therapy with the same dosimetric quality of what is achievable with other systems routinely used in the clinics without significantly changing the current practice. Additional studies which customize the optimization parameters for each delivery device would complement the spectrum of investigations. SAGE Publications 2018-10-07 /pmc/articles/PMC6176542/ /pubmed/30295172 http://dx.doi.org/10.1177/1533033818803882 Text en © The Author(s) 2018 http://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (http://www.creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Original Article
Cozzi, Luca
Fogliata, Antonella
Thompson, Stephen
Franzese, Ciro
Franceschini, Davide
de Rose, Fiorenza
Tomatis, Stefano
Scorsetti, Marta
Critical Appraisal of the Treatment Planning Performance of Volumetric Modulated Arc Therapy by Means of a Dual Layer Stacked Multileaf Collimator for Head and Neck, Breast, and Prostate
title Critical Appraisal of the Treatment Planning Performance of Volumetric Modulated Arc Therapy by Means of a Dual Layer Stacked Multileaf Collimator for Head and Neck, Breast, and Prostate
title_full Critical Appraisal of the Treatment Planning Performance of Volumetric Modulated Arc Therapy by Means of a Dual Layer Stacked Multileaf Collimator for Head and Neck, Breast, and Prostate
title_fullStr Critical Appraisal of the Treatment Planning Performance of Volumetric Modulated Arc Therapy by Means of a Dual Layer Stacked Multileaf Collimator for Head and Neck, Breast, and Prostate
title_full_unstemmed Critical Appraisal of the Treatment Planning Performance of Volumetric Modulated Arc Therapy by Means of a Dual Layer Stacked Multileaf Collimator for Head and Neck, Breast, and Prostate
title_short Critical Appraisal of the Treatment Planning Performance of Volumetric Modulated Arc Therapy by Means of a Dual Layer Stacked Multileaf Collimator for Head and Neck, Breast, and Prostate
title_sort critical appraisal of the treatment planning performance of volumetric modulated arc therapy by means of a dual layer stacked multileaf collimator for head and neck, breast, and prostate
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6176542/
https://www.ncbi.nlm.nih.gov/pubmed/30295172
http://dx.doi.org/10.1177/1533033818803882
work_keys_str_mv AT cozziluca criticalappraisalofthetreatmentplanningperformanceofvolumetricmodulatedarctherapybymeansofaduallayerstackedmultileafcollimatorforheadandneckbreastandprostate
AT fogliataantonella criticalappraisalofthetreatmentplanningperformanceofvolumetricmodulatedarctherapybymeansofaduallayerstackedmultileafcollimatorforheadandneckbreastandprostate
AT thompsonstephen criticalappraisalofthetreatmentplanningperformanceofvolumetricmodulatedarctherapybymeansofaduallayerstackedmultileafcollimatorforheadandneckbreastandprostate
AT franzeseciro criticalappraisalofthetreatmentplanningperformanceofvolumetricmodulatedarctherapybymeansofaduallayerstackedmultileafcollimatorforheadandneckbreastandprostate
AT franceschinidavide criticalappraisalofthetreatmentplanningperformanceofvolumetricmodulatedarctherapybymeansofaduallayerstackedmultileafcollimatorforheadandneckbreastandprostate
AT derosefiorenza criticalappraisalofthetreatmentplanningperformanceofvolumetricmodulatedarctherapybymeansofaduallayerstackedmultileafcollimatorforheadandneckbreastandprostate
AT tomatisstefano criticalappraisalofthetreatmentplanningperformanceofvolumetricmodulatedarctherapybymeansofaduallayerstackedmultileafcollimatorforheadandneckbreastandprostate
AT scorsettimarta criticalappraisalofthetreatmentplanningperformanceofvolumetricmodulatedarctherapybymeansofaduallayerstackedmultileafcollimatorforheadandneckbreastandprostate