Cargando…

Safety of intrauterine devices in MRI

OBJECTIVES: The paucity of safety information on intrauterine devices (IUD) for magnetic resonance imaging (MRI) examinations is clinically relevant. The aim of this study is to evaluate the MRI safety of clinically used IUDs composed of copper/gold and stainless steel at 1.5T and 3.0T. MATERIALS AN...

Descripción completa

Detalles Bibliográficos
Autores principales: Bussmann, Simon, Luechinger, Roger, Froehlich, Johannes M., von Weymarn, Constantin, Reischauer, Carolin, Koh, Dow Mu, Gutzeit, Andreas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6177157/
https://www.ncbi.nlm.nih.gov/pubmed/30300364
http://dx.doi.org/10.1371/journal.pone.0204220
_version_ 1783361820808970240
author Bussmann, Simon
Luechinger, Roger
Froehlich, Johannes M.
von Weymarn, Constantin
Reischauer, Carolin
Koh, Dow Mu
Gutzeit, Andreas
author_facet Bussmann, Simon
Luechinger, Roger
Froehlich, Johannes M.
von Weymarn, Constantin
Reischauer, Carolin
Koh, Dow Mu
Gutzeit, Andreas
author_sort Bussmann, Simon
collection PubMed
description OBJECTIVES: The paucity of safety information on intrauterine devices (IUD) for magnetic resonance imaging (MRI) examinations is clinically relevant. The aim of this study is to evaluate the MRI safety of clinically used IUDs composed of copper/gold and stainless steel at 1.5T and 3.0T. MATERIALS AND METHODS: We assessed and compared the displacement force, torque effects, presence of imaging artifacts and heating of IUDs composed of copper/gold (western IUDs) and stainless steel (China) on 1.5 and 3.0T MRI systems. RESULTS: Gold/Copper IUDs can show small deflection angles of 7° ± 7° in the worst-case field gradient of 40T/m (equivalent to magnetic force of 0.5 mN), while the stainless steel IUD experienced significant magnetic force and deflection (Force > 7.5 N; deflection angle 90° ± 1°). Manual rotation and suspension method show no torque effects on gold/copper IUDs but high torque effects were observed by manual rotation on the stainless steel IUD. Heating measurements showed a temperature increase (rescaled to a wbSAR of 4 W/kg) of 1.4°C at 1.5T / 3.4°C at 3.0 T (stainless steel IUD), 3.2°C at 1.5 T / 3.8°C at 3 T (copper/gold IUD), 3.3°C at 1.5 T / 4.8°C at 3 T (copper 1), 3.8°C at 1.5 T / 4.8°C at 3 T (copper 2). The visible imaging artifacts of the copper and gold IUDs at 3 T MRI reach a diameter of 4 mm ± 1 mm, while the stainless steel IUD resulted in artifacts measuring 200mm ± 10 mm when using gradient echo pulse sequences. CONCLUSIONS: Standard IUDs (copper/gold) can be considered as conditional for MR safety at 1.5 T and 3.0 T, demonstrating at wbSAR up to 4W/kg and a magnetic field gradient of up to 40T/m with minimal imaging artifacts. The stainless steel IUD, however, induces unacceptable artifacts and is potentially harmful to patients during MRI due to high magnetic dislocation forces and torque (MR unsafe).
format Online
Article
Text
id pubmed-6177157
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-61771572018-10-19 Safety of intrauterine devices in MRI Bussmann, Simon Luechinger, Roger Froehlich, Johannes M. von Weymarn, Constantin Reischauer, Carolin Koh, Dow Mu Gutzeit, Andreas PLoS One Research Article OBJECTIVES: The paucity of safety information on intrauterine devices (IUD) for magnetic resonance imaging (MRI) examinations is clinically relevant. The aim of this study is to evaluate the MRI safety of clinically used IUDs composed of copper/gold and stainless steel at 1.5T and 3.0T. MATERIALS AND METHODS: We assessed and compared the displacement force, torque effects, presence of imaging artifacts and heating of IUDs composed of copper/gold (western IUDs) and stainless steel (China) on 1.5 and 3.0T MRI systems. RESULTS: Gold/Copper IUDs can show small deflection angles of 7° ± 7° in the worst-case field gradient of 40T/m (equivalent to magnetic force of 0.5 mN), while the stainless steel IUD experienced significant magnetic force and deflection (Force > 7.5 N; deflection angle 90° ± 1°). Manual rotation and suspension method show no torque effects on gold/copper IUDs but high torque effects were observed by manual rotation on the stainless steel IUD. Heating measurements showed a temperature increase (rescaled to a wbSAR of 4 W/kg) of 1.4°C at 1.5T / 3.4°C at 3.0 T (stainless steel IUD), 3.2°C at 1.5 T / 3.8°C at 3 T (copper/gold IUD), 3.3°C at 1.5 T / 4.8°C at 3 T (copper 1), 3.8°C at 1.5 T / 4.8°C at 3 T (copper 2). The visible imaging artifacts of the copper and gold IUDs at 3 T MRI reach a diameter of 4 mm ± 1 mm, while the stainless steel IUD resulted in artifacts measuring 200mm ± 10 mm when using gradient echo pulse sequences. CONCLUSIONS: Standard IUDs (copper/gold) can be considered as conditional for MR safety at 1.5 T and 3.0 T, demonstrating at wbSAR up to 4W/kg and a magnetic field gradient of up to 40T/m with minimal imaging artifacts. The stainless steel IUD, however, induces unacceptable artifacts and is potentially harmful to patients during MRI due to high magnetic dislocation forces and torque (MR unsafe). Public Library of Science 2018-10-09 /pmc/articles/PMC6177157/ /pubmed/30300364 http://dx.doi.org/10.1371/journal.pone.0204220 Text en © 2018 Bussmann et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Bussmann, Simon
Luechinger, Roger
Froehlich, Johannes M.
von Weymarn, Constantin
Reischauer, Carolin
Koh, Dow Mu
Gutzeit, Andreas
Safety of intrauterine devices in MRI
title Safety of intrauterine devices in MRI
title_full Safety of intrauterine devices in MRI
title_fullStr Safety of intrauterine devices in MRI
title_full_unstemmed Safety of intrauterine devices in MRI
title_short Safety of intrauterine devices in MRI
title_sort safety of intrauterine devices in mri
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6177157/
https://www.ncbi.nlm.nih.gov/pubmed/30300364
http://dx.doi.org/10.1371/journal.pone.0204220
work_keys_str_mv AT bussmannsimon safetyofintrauterinedevicesinmri
AT luechingerroger safetyofintrauterinedevicesinmri
AT froehlichjohannesm safetyofintrauterinedevicesinmri
AT vonweymarnconstantin safetyofintrauterinedevicesinmri
AT reischauercarolin safetyofintrauterinedevicesinmri
AT kohdowmu safetyofintrauterinedevicesinmri
AT gutzeitandreas safetyofintrauterinedevicesinmri